These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

87 related articles for article (PubMed ID: 8659979)

  • 1. Use of skin staples for securing the mesh in the Lichtenstein repair of inguinal hernia.
    Egger B; Fawcett J; Dowling BL
    Ann R Coll Surg Engl; 1996 Jan; 78(1):63-4. PubMed ID: 8659979
    [No Abstract]   [Full Text] [Related]  

  • 2. Prospective randomized controlled trial to compare skin staples and polypropylene for securing the mesh in inguinal hernia repair.
    Mills IW; McDermott IM; Ratliff DA
    Br J Surg; 1998 Jun; 85(6):790-2. PubMed ID: 9667709
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of skin staples for securing the mesh in the Lichtenstein repair of inguinal hernia.
    Fligelstone L; Wanendeya N; Palmer B
    Ann R Coll Surg Engl; 1996 Jul; 78(4):398. PubMed ID: 8712668
    [No Abstract]   [Full Text] [Related]  

  • 4. Use of skin staples for securing the mesh in the Lichtenstein repair of inguinal hernia.
    Kingsnorth AN
    Ann R Coll Surg Engl; 1996 Jul; 78(4):398. PubMed ID: 8712669
    [No Abstract]   [Full Text] [Related]  

  • 5. Use of skin staples for securing the mesh in the Lichtenstein repair of inguinal hernia.
    Cheek C
    Ann R Coll Surg Engl; 1996 Jul; 78(4):398. PubMed ID: 8712667
    [No Abstract]   [Full Text] [Related]  

  • 6. Use of skin staples for securing the mesh in the Lichtenstein repair of inguinal hernia.
    Gould SW
    Ann R Coll Surg Engl; 1996 May; 78(3 ( Pt 1)):235. PubMed ID: 8779525
    [No Abstract]   [Full Text] [Related]  

  • 7. Use of skin staples for securing the mesh in the Lichtenstein repair of inguinal hernia.
    Ackroyd R; Morris IR
    Ann R Coll Surg Engl; 1996 May; 78(3 ( Pt 1)):235. PubMed ID: 8779524
    [No Abstract]   [Full Text] [Related]  

  • 8. Prospective randomized controlled trial to compare skin staples and polypropylene for securing the mesh in inguinal hernia repair.
    RoshanLall C; Hutchinson GH
    Br J Surg; 1998 Oct; 85(10):1451. PubMed ID: 9782038
    [No Abstract]   [Full Text] [Related]  

  • 9. Polypropylene suture versus skin staples for securing mesh in lichtenstein inguinal hernioplasty.
    Khan AA; Majeed S; Shahzadi M; Hussain SM; Ali MZ; Siddique K
    J Coll Physicians Surg Pak; 2014 Feb; 24(2):88-90. PubMed ID: 24491000
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Risk of recurrence 5 years or more after primary Lichtenstein mesh and sutured inguinal hernia repair.
    Bisgaard T; Bay-Nielsen M; Christensen IJ; Kehlet H
    Br J Surg; 2007 Aug; 94(8):1038-40. PubMed ID: 17607708
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Comparison between two methods of inguinal hernia surgery--Lichtenstein and Desarda].
    Mitura K; Romańczuk M
    Pol Merkur Lekarski; 2008 May; 24(143):392-5. PubMed ID: 18634379
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Randomized clinical trial of lightweight composite mesh for Lichtenstein inguinal hernia repair.
    Post S; Weiss B; Willer M; Neufang T; Lorenz D
    Br J Surg; 2004 Jan; 91(1):44-8. PubMed ID: 14716792
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk of recurrence 5 years or more after primary Lichtenstein mesh and sutured inguinal hernia repair (Br J Surg 2007; 94: 1038-1040).
    Nowack M; Metzger J
    Br J Surg; 2007 Nov; 94(11):1438; author reply 1438-9. PubMed ID: 17939134
    [No Abstract]   [Full Text] [Related]  

  • 14. First results of Lichtenstein hernia repair with Ultrapro-mesh as cost saving procedure--quality control combined with a modified quality of life questionnaire (SF-36) in a series of ambulatory operated patients.
    Holzheimer RG
    Eur J Med Res; 2004 Jun; 9(6):323-7. PubMed ID: 15257875
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The Lichtenstein open tension-free inguinal hernia repair using a new prosthetic mesh-Bulgarian irresorbable ampoxen.
    Velitchkov NG; Losanoff JE; Kjossev KT; Grigorov GI; Kirov GK; Losanoff CE
    Int Surg; 1996; 81(2):205-9. PubMed ID: 8912095
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Laparoscopic and open inguinal hernia repair with alloplastic material: do the subjective and objective parameters differ in the long-term course?
    Lauscher JC; Yafaei K; Buhr HJ; Ritz JP
    Surg Laparosc Endosc Percutan Tech; 2008 Oct; 18(5):457-63. PubMed ID: 18936666
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Inguinal hernia repair with mesh plug technique (initial experiences with a new, tension-free surgical method)].
    Belágyi T; Hegedüs L; Neuberger G; Vasi I; Wellner I; Oláh A
    Magy Seb; 2000 Jun; 53(3):117-9. PubMed ID: 11299498
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Early results of inguinal hernia repair by the 'mesh plug' technique--first 200 cases.
    Fasih T; Mahapatra TK; Waddington RT
    Ann R Coll Surg Engl; 2000 Nov; 82(6):396-400. PubMed ID: 11103156
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of Shouldice and Lichtenstein repair for treatment of primary inguinal hernia.
    Aytaç B; Cakar KS; Karamercan A
    Acta Chir Belg; 2004 Aug; 104(4):418-21. PubMed ID: 15469153
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lichtenstein tension-free repair of inguinal hernia.
    Gourgiotis S; Germanos S; Stratopoulos C; Moustafellos P; Panteli A; Hadjiyannakis E
    Chirurgia (Bucur); 2006; 101(5):509-12. PubMed ID: 17278643
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.