These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 8664012)

  • 1. Multilevel somatosensory evoked potentials (SEPs) for spinal cord monitoring in descending thoracic and thoraco-abdominal aortic surgery.
    Guérit JM; Verhelst R; Rubay J; Khoury G; Matta A; Dion R
    Eur J Cardiothorac Surg; 1996; 10(2):93-103; discussion 103-4. PubMed ID: 8664012
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The risk of ischemic spinal cord injury in patients undergoing graft replacement for thoracoabdominal aortic aneurysms.
    Grabitz K; Sandmann W; Stühmeier K; Mainzer B; Godehardt E; Ohle B; Hartwich U
    J Vasc Surg; 1996 Feb; 23(2):230-40. PubMed ID: 8637100
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sensitivity, specificity, and surgical impact of somatosensory evoked potentials in descending aorta surgery.
    Guerit JM; Witdoeckt C; Verhelst R; Matta AJ; Jacquet LM; Dion RA
    Ann Thorac Surg; 1999 Jun; 67(6):1943-6; discussion 1953-8. PubMed ID: 10391345
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Upper and lower extremity somatosensory evoked potential recording during surgery for aneurysms of the descending thoracic aorta.
    Shahin GM; Hamerlijnck RP; Schepens MA; Ter Beek HT; Vermeulen FE; Boezeman EH
    Eur J Cardiothorac Surg; 1996; 10(5):299-304. PubMed ID: 8737684
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Somatosensory evoked potentials during exclusion and reperfusion of critical aortic segments in thoracoabdominal aortic aneurysm surgery.
    Schepens MA; Boezeman EH; Hamerlijnck RP; ter Beek H; Vermeulen FE
    J Card Surg; 1994 Nov; 9(6):692-702. PubMed ID: 7841650
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monitoring for spinal cord ischemia by use of the evoked spinal cord potentials during aortic aneurysm surgery.
    Yamamoto N; Takano H; Kitagawa H; Kawaguchi Y; Tsuji H; Uozaki Y
    J Vasc Surg; 1994 Nov; 20(5):826-33. PubMed ID: 7966819
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of somatosensory evoked potentials for thoracic and thoracoabdominal aortic resections.
    Galla JD; Ergin MA; Lansman SL; McCullough JN; Nguyen KH; Spielvogel D; Klein JJ; Griepp RB
    Ann Thorac Surg; 1999 Jun; 67(6):1947-52; discussion 1953-8. PubMed ID: 10391346
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of spinal cord ischemia during operations upon the thoracic aorta: initial clinical experience.
    Cunningham JN; Laschinger JC; Merkin HA; Nathan IM; Colvin S; Ransohoff J; Spencer FC
    Ann Surg; 1982 Sep; 196(3):285-96. PubMed ID: 7114935
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prevention of spinal cord ischemia in surgery of thoraco-abdominal aneurysms. The Bio Medicus pump, the recording of somatosensory evoked potentials and the impact on surgical strategy.
    de Mol B; Hamerlijnck R; Boezeman E; Vermeulen FE
    Eur J Cardiothorac Surg; 1990; 4(12):658-64. PubMed ID: 2288746
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental and clinical use of somatosensory evoked potentials in surgery of aneurysms of the descending thoracic aorta.
    de Mol BA; Boezeman EH; Hamerlijnck RP; de Geest R
    Thorac Cardiovasc Surg; 1990 Jun; 38(3):146-50. PubMed ID: 2375029
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. IV. Clinical observations and results.
    Cunningham JN; Laschinger JC; Spencer FC
    J Thorac Cardiovasc Surg; 1987 Aug; 94(2):275-85. PubMed ID: 3613628
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prevention of spinal cord ischemia by monitoring spinal cord perfusion pressure and somatosensory evoked potentials.
    Maeda S; Miyamoto T; Murata H; Yamashita K
    J Cardiovasc Surg (Torino); 1989; 30(4):565-71. PubMed ID: 2777863
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Protection of the spinal cord during surgery of thoraco-abdominal aortic aneurysms.
    Bachet J; Guilmet D; Rosier J; Cron C; Dreyfus G; Goudot B; Piquois A; Brodaty D; Dubois C; de Lentdecker P
    Eur J Cardiothorac Surg; 1996; 10(10):817-25. PubMed ID: 8911833
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Prevention of spinal cord ischemia after cross-clamping of the thoracic aorta--monitoring of spinal cord perfusion pressure and somatosensory evoked potentials].
    Maeda S; Miyamoto T; Murata H; Yamashita K; Iwaoka S; Yasuoka T; Hara Y; Ueda T
    Nihon Kyobu Geka Gakkai Zasshi; 1989 Sep; 37(9):1923-31. PubMed ID: 2600466
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical application of evoked spinal cord potentials elicited by direct stimulation of the cord during temporary occlusion of the thoracic aorta.
    Matsui Y; Goh K; Shiiya N; Murashita T; Miyama M; Ohba J; Gohda T; Sakuma M; Yasuda K; Tanabe T
    J Thorac Cardiovasc Surg; 1994 Jun; 107(6):1519-27. PubMed ID: 8196398
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental and clinical assessment of the adequacy of partial bypass in maintenance of spinal cord blood flow during operations on the thoracic aorta.
    Laschinger JC; Cunningham JN; Nathan IM; Knopp EA; Cooper MM; Spencer FC
    Ann Thorac Surg; 1983 Oct; 36(4):417-26. PubMed ID: 6625737
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Surgical treatment of thoraco-abdominal aneurysm. Indications and results].
    Sandmann W; Grabitz K; Torsello G; Kniemeyer HW; Stühmeier K; Mainzer B
    Chirurg; 1995 Sep; 66(9):845-56. PubMed ID: 7587556
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intraoperative adjuncts of spinal cord protection.
    Robertazzi RR; Cunningham JN
    Semin Thorac Cardiovasc Surg; 1998 Jan; 10(1):29-34. PubMed ID: 9469775
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Monitoring of somatosensory evoked potentials: a primer on the intraoperative detection of spinal cord ischemia during aortic reconstructive surgery.
    Robertazzi RR; Cunningham JN
    Semin Thorac Cardiovasc Surg; 1998 Jan; 10(1):11-7. PubMed ID: 9469772
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of the electrospinogram for predicting harmful spinal cord ischemia during repair of thoracic or thoracoabdominal aortic aneurysms.
    Stühmeier KD; Grabitz K; Mainzer B; Sandmann W; Tarnow J
    Anesthesiology; 1993 Dec; 79(6):1170-6; discussion 27A-28A. PubMed ID: 8267191
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.