4. Ascorbate interferences in common clinical assays performed on three analyzers. Freemantle J; Freemantle MJ; Badrick T Clin Chem; 1994 Jun; 40(6):950-1. PubMed ID: 8087995 [No Abstract] [Full Text] [Related]
5. Eliminating bilirubin interference in Cobas MIRA assay of creatinine in serum. Moshkin AV Clin Chem; 1994 Aug; 40(8):1600-1. PubMed ID: 8045010 [No Abstract] [Full Text] [Related]
6. National Cholesterol Education Program recommendations for measurement of low-density lipoprotein cholesterol: executive summary. The National Cholesterol Education Program Working Group on Lipoprotein Measurement. Bachorik PS; Ross JW Clin Chem; 1995 Oct; 41(10):1414-20. PubMed ID: 7586510 [No Abstract] [Full Text] [Related]
8. The status of bilirubin measurements in U.S. laboratories: why is accuracy elusive? Lo SF; Doumas BT Semin Perinatol; 2011 Jun; 35(3):141-7. PubMed ID: 21641487 [TBL] [Abstract][Full Text] [Related]
11. Functional sensitivity of thyrotropin assays. Williams JS; Jackson TM Clin Chem; 1995 Mar; 41(3):474-7. PubMed ID: 7882531 [No Abstract] [Full Text] [Related]
12. The power (sensitivity) of quality control plans in clinical chemistry. Saracci R Am J Clin Pathol; 1974 Sep; 62(3):398-406. PubMed ID: 4416421 [No Abstract] [Full Text] [Related]
13. A study of interferences in routine methods for creatinine measurement. Kenny D Scand J Clin Lab Invest Suppl; 1993; 212():43-7. PubMed ID: 8465153 [TBL] [Abstract][Full Text] [Related]
14. European specifications for imprecision and inaccuracy compared with US CLIA proficiency-testing criteria. Stöckl D Clin Chem; 1995 Jan; 41(1):120-1. PubMed ID: 7813063 [No Abstract] [Full Text] [Related]
15. Development of criteria for the evaluation of reference method values. Stöckl D; Reinauer H Scand J Clin Lab Invest Suppl; 1993; 212():16-8. PubMed ID: 8465146 [TBL] [Abstract][Full Text] [Related]
16. The errors of our ways. Blumenthal D Clin Chem; 1997 Aug; 43(8 Pt 1):1305. PubMed ID: 9267304 [No Abstract] [Full Text] [Related]
17. Evaluation of new oxidation methods for the measurement of bilirubin on the aeroset clinical chemistry analyzer and comparison with methods on the Hitachi 717. Sturm E; Albrecht-Groos R; Seyfarth M Clin Lab; 2002; 48(7-8):401-5. PubMed ID: 12146574 [TBL] [Abstract][Full Text] [Related]
19. Commutability of reference materials in clinical chemistry. Franzini C J Int Fed Clin Chem; 1993 Sep; 5(4):169-73. PubMed ID: 10146393 [TBL] [Abstract][Full Text] [Related]
20. The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods. Ross JW; Miller WG; Myers GL; Praestgaard J Arch Pathol Lab Med; 1998 Jul; 122(7):587-608. PubMed ID: 9674541 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]