These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 8665679)

  • 21. Specific heparin preparations interfere with the simultaneous measurement of ionized magnesium and ionized calcium.
    Lyon ME; Bremner D; Laha T; Malik S; Henderson PJ; Kenny MA
    Clin Biochem; 1995 Feb; 28(1):79-84. PubMed ID: 7720231
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [The ionized calcium fraction of the blood: dependence on different methodical factors].
    Kölling K
    Zentralbl Veterinarmed A; 1991 Oct; 38(8):629-38. PubMed ID: 1771985
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Neutral ionophore-based selective electrode for assaying the activity of magnesium in undiluted blood serum.
    Rouilly M; Rusterholz B; Spichiger UE; Simon W
    Clin Chem; 1990 Mar; 36(3):466-9. PubMed ID: 2311214
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Serum ionized magnesium and other electrolytes in the antenatal period of human pregnancy.
    Handwerker SM; Altura BT; Altura BM
    J Am Coll Nutr; 1996 Feb; 15(1):36-43. PubMed ID: 8632112
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Analytical evaluation of Kone Microlyte determination of ionized magnesium.
    van Ingen HE; Huijgen HJ; Kok WT; Sanders GT
    Clin Chem; 1994 Jan; 40(1):52-5. PubMed ID: 8287544
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Evaluation of two Mg2+-selective electrodes by means of a flow-through device.
    Boguschewski FH; Seyfarth M; Heidrich JP
    Clin Chem Lab Med; 2002 Mar; 40(3):308-11. PubMed ID: 12005223
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Concentrations of ionized and total magnesium and calcium in healthy horses: effects of age, pregnancy, lactation, pH and sample type.
    Berlin D; Aroch I
    Vet J; 2009 Sep; 181(3):305-11. PubMed ID: 18467135
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Determination of electrolytes in serum and plasma].
    Külpmann WR
    Wien Klin Wochenschr Suppl; 1992; 192():37-41. PubMed ID: 1502823
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Comparative evaluation of two calcium ion-selective electrode systems, and their utility for monitoring steady-state changes in [Ca2+].
    Drop LJ; Tochka LN; Misiano DR
    Clin Chem; 1982 Jan; 28(1):129-33. PubMed ID: 7055896
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Relationship between ionized and total magnesium in serum.
    Külpmann WR; Gerlach M
    Scand J Clin Lab Invest Suppl; 1996; 224():251-8. PubMed ID: 8865441
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of an ion-selective electrolyte analyzer: Microlyte 6.
    Markova V; Sirakova I; Tsvetkova T; Nikolov R
    Folia Med (Plovdiv); 1997; 39(1):34-8. PubMed ID: 9141789
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of pH and NaCl on measurements of ionized calcium in matrices of serum and human albumin with a new calcium-selective electrode.
    Rehfeld SJ; Barkeley J; Loken HF
    Clin Chem; 1984 Feb; 30(2):304-7. PubMed ID: 6692542
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ion effects in measurement of ionized calcium with a calcium-selective electrode.
    Kaufman RA; Tietz NW
    Clin Chem; 1980 Apr; 26(5):640-4. PubMed ID: 6266696
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Circulating divalent cations in asymptomatic ovarian hyperstimulation and in vitro fertilization patients.
    O'Shaughnessy A; Muneyyirci-Delale O; Nacharaju VL; Dalloul M; Altura BM; Altura BT
    Gynecol Obstet Invest; 2001; 52(4):237-42. PubMed ID: 11729336
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Ionized magnesium in serum and ultrafiltrate: pH and bicarbonate effect on measurements with the AVL 988-4 electrolyte analyzer.
    Zoppi F; Cristalli C
    Clin Chem; 1998 Mar; 44(3):668-71. PubMed ID: 9510881
    [No Abstract]   [Full Text] [Related]  

  • 36. Measurement of ionized magnesium in whole blood, plasma and serum with a new ion-selective electrode in healthy and diseased human subjects.
    Altura BT; Altura BM
    Magnes Trace Elem; 1991-1992; 10(2-4):90-8. PubMed ID: 1844565
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Measurement of serum ionized versus total levels of magnesium and calcium in hemodialysis patients.
    Saha H; Harmoinen A; Pietilä K; Mörsky P; Pasternack A
    Clin Nephrol; 1996 Nov; 46(5):326-31. PubMed ID: 8953122
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Clinical findings on human blood with the KONE ISE for Mg2+.
    Maj-Zurawska M
    Scand J Clin Lab Invest Suppl; 1994; 217():69-76. PubMed ID: 7939387
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Factors affecting the determination of ionized calcium in blood.
    Brauman J; Delvigne C; Deconinck I; Willems D
    Scand J Clin Lab Invest Suppl; 1983; 165():27-31. PubMed ID: 6578571
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Serum ionized magnesium changes during and immediately after liver transplantation.
    Douzdjian V; Filos D; Okorodudu AO
    Ann Clin Lab Sci; 1995; 25(4):297-305. PubMed ID: 7668814
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.