These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 8669603)

  • 21. Quantifying ventilator unloading in CPAP ventilation.
    Guy EFS; Chase JG; Knopp JL; Shaw GM
    Comput Biol Med; 2022 Mar; 142():105225. PubMed ID: 35032739
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Changes in work of breathing during continuous positive airway pressure with increased airway resistance.
    Yamazaki Y; Yamakage M; Ujike Y; Namiki A
    Chest; 1994 Mar; 105(3):860-3. PubMed ID: 8131552
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing.
    Aerts JG; van den Berg B; Bogaard JM
    Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of total resistive work of breathing in two generations of ventilators in an animal model.
    Heulitt MJ; Torres A; Anders M; Wilson SW; Carmack J
    Pediatr Pulmonol; 1996 Jul; 22(1):58-66. PubMed ID: 8856804
    [TBL] [Abstract][Full Text] [Related]  

  • 25. An in vitro evaluation of the influence of neonatal endotracheal tube diameter and length on the work of breathing.
    Miyake F; Suga R; Akiyama T; Namba F
    Paediatr Anaesth; 2018 May; 28(5):458-462. PubMed ID: 29633434
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of Heat Moisture Exchanger on Aerosol Drug Delivery and Airway Resistance in Simulated Ventilator-Dependent Adults Using Jet and Mesh Nebulizers.
    Ari A; Dang T; Al Enazi FH; Alqahtani MM; Alkhathami A; Qoutah R; Almamary AS; Fink JB
    J Aerosol Med Pulm Drug Deliv; 2018 Feb; 31(1):42-48. PubMed ID: 28829202
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Humidification performance of humidifying devices for tracheostomized patients with spontaneous breathing: a bench study.
    Chikata Y; Oto J; Onodera M; Nishimura M
    Respir Care; 2013 Sep; 58(9):1442-8. PubMed ID: 23386732
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Site of pressure measurement during spontaneous breathing with continuous positive airway pressure: effect on calculating imposed work of breathing.
    Banner MJ; Kirby RR; Blanch PB
    Crit Care Med; 1992 Apr; 20(4):528-33. PubMed ID: 1559368
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Prediction of minimal pressure support during weaning from mechanical ventilation.
    Nathan SD; Ishaaya AM; Koerner SK; Belman MJ
    Chest; 1993 Apr; 103(4):1215-9. PubMed ID: 8131468
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Impact of heat and moisture exchangers on ventilatory pattern and respiratory mechanics in spontaneously breathing patients.
    Natalini G; Bardini P; Latronico N; Candiani A
    Monaldi Arch Chest Dis; 1994 Dec; 49(6):561-4. PubMed ID: 7711718
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Potential inadequacy of automatic tube compensation to decrease inspiratory work load after at least 48 hours of endotracheal tube use in the clinical setting.
    Oto J; Imanaka H; Nakataki E; Ono R; Nishimura M
    Respir Care; 2012 May; 57(5):697-703. PubMed ID: 22153219
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The effects of pressure- versus volume-controlled ventilation on ventilator work of breathing.
    Monjezi M; Jamaati H
    Biomed Eng Online; 2020 Sep; 19(1):72. PubMed ID: 32933529
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In vitro and in vivo evaluation of a new active heat moisture exchanger.
    Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M
    Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Home versus intensive care pressure support devices. Experimental and clinical comparison.
    Lofaso F; Brochard L; Hang T; Lorino H; Harf A; Isabey D
    Am J Respir Crit Care Med; 1996 May; 153(5):1591-9. PubMed ID: 8630607
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Additional work of breathing imposed by endotracheal tubes, breathing circuits, and intensive care ventilators.
    Bersten AD; Rutten AJ; Vedig AE; Skowronski GA
    Crit Care Med; 1989 Jul; 17(7):671-7. PubMed ID: 2736929
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings.
    Unal N; Kanhai JK; Buijk SL; Pompe JC; Holland WP; Gültuna I; Ince C; Saygin B; Bruining HA
    Intensive Care Med; 1998 Feb; 24(2):138-46. PubMed ID: 9539071
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Pressure stability with CPAP devices: A bench evaluation.
    Louis B; Leroux K; Boucherie M; Isabey D; Grillier-Lanoir V; Fauroux B; Lofaso F
    Sleep Med; 2010 Jan; 11(1):96-9. PubMed ID: 19892594
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Spontaneous Breathing and Imposed Work During Pediatric Mechanical Ventilation: A Bench Study.
    van Dijk J; Blokpoel RGT; Koopman AA; Brandsema R; Newth CJL; Kneyber MCJ
    Pediatr Crit Care Med; 2020 Jul; 21(7):e449-e455. PubMed ID: 32427436
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
    Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L
    Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.