232 related articles for article (PubMed ID: 8671824)
1. Iohexol clearance for GFR-determination in renal failure--single or multiple plasma sampling?
Sterner G; Frennby B; Hultberg B; Almen T
Nephrol Dial Transplant; 1996 Mar; 11(3):521-5. PubMed ID: 8671824
[TBL] [Abstract][Full Text] [Related]
2. [Validity of iohexol clearance in patients with chronic renal failure and normal renal function in comparison to (99m)Tc-DTPA-clearance].
Wiendieck E; Hartung R; Fünfstück R; Keil E; Gottschild D; Stein G
Dtsch Med Wochenschr; 2003 Jan; 128(3):76-80. PubMed ID: 12529836
[TBL] [Abstract][Full Text] [Related]
3. The use of iohexol clearance to determine GFR in patients with severe chronic renal failure--a comparison between different clearance techniques.
Frennby B; Sterner G; Almén T; Hagstam KE; Hultberg B; Jacobsson L
Clin Nephrol; 1995 Jan; 43(1):35-46. PubMed ID: 7697934
[TBL] [Abstract][Full Text] [Related]
4. Comparison of serum iohexol clearance and plasma creatinine clearance in clinically normal horses.
Wilson KE; Wilcke JR; Crisman MV; Ward DL; McKenzie HC; Scarratt WK
Am J Vet Res; 2009 Dec; 70(12):1545-50. PubMed ID: 19951127
[TBL] [Abstract][Full Text] [Related]
5. GFR determination in adults with a single-sample iohexol plasma clearance method based on the mean sojourn time.
Gref M; Karp K
Nephrol Dial Transplant; 2007 Nov; 22(11):3166-73. PubMed ID: 17675331
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of a single injection method, using iohexol, for estimating glomerular filtration rate in cats and dogs.
Brown SA; Finco DR; Boudinot FD; Wright J; Taver SL; Cooper T
Am J Vet Res; 1996 Jan; 57(1):105-10. PubMed ID: 8720247
[TBL] [Abstract][Full Text] [Related]
7. Estimation of glomerular filtration rate via 2- and 4-sample plasma clearance of iohexol and creatinine in clinically normal cats.
Heiene R; Reynolds BS; Bexfield NH; Larsen S; Gerritsen RJ
Am J Vet Res; 2009 Feb; 70(2):176-85. PubMed ID: 19231948
[TBL] [Abstract][Full Text] [Related]
8. Validation of a new plasma cystatin C-based formula and the Modification of Diet in Renal Disease creatinine-based formula for determination of glomerular filtration rate.
Sterner G; Björk J; Carlson J; Grubb A; Nyman U
Scand J Urol Nephrol; 2009; 43(3):242-9. PubMed ID: 19291590
[TBL] [Abstract][Full Text] [Related]
9. Plasma clearance of iodine contrast media as a measure of glomerular filtration rate in critically ill patients.
Erley CM; Bader BD; Berger ED; Vochazer A; Jorzik JJ; Dietz K; Risler T
Crit Care Med; 2001 Aug; 29(8):1544-50. PubMed ID: 11505124
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of sample bias for measuring plasma iohexol clearance in kidney transplantation.
Stolz A; Hoizey G; Toupance O; Lavaud S; Vitry F; Chanard J; Rieu P
Transplantation; 2010 Feb; 89(4):440-5. PubMed ID: 20177346
[TBL] [Abstract][Full Text] [Related]
11. Correct evaluation of renal glomerular filtration rate requires clearance assays.
Hjorth L; Wiebe T; Karpman D
Pediatr Nephrol; 2002 Oct; 17(10):847-51. PubMed ID: 12376815
[TBL] [Abstract][Full Text] [Related]
12. Clearance of iohexol, chromium-51-ethylenediaminetetraacetic acid, and creatinine for determining the glomerular filtration rate in pigs with normal renal function: comparison of different clearance techniques.
Frennby B; Sterner G; Almén T; Chai CM; Jönsson BA; Månsson S
Acad Radiol; 1996 Aug; 3(8):651-9. PubMed ID: 8796729
[TBL] [Abstract][Full Text] [Related]
13. Relationship between plasma iohexol clearance and urinary exogenous creatinine clearance in dogs.
Finco DR; Braselton WE; Cooper TA
J Vet Intern Med; 2001; 15(4):368-73. PubMed ID: 11467595
[TBL] [Abstract][Full Text] [Related]
14. Estimated glomerular filtration rate (eGFRCystC) from serum cystatin C shows strong agreement with iohexol clearance in patients with low GFR.
Jonsson AS; Flodin M; Hansson LO; Larsson A
Scand J Clin Lab Invest; 2007; 67(8):801-9. PubMed ID: 17852801
[TBL] [Abstract][Full Text] [Related]
15. Suitability of a simplified technique based on iohexol for decentralized measurement of glomerular filtration rate.
Bird NJ; Peters C; Michell AR; Peters AM
Scand J Urol Nephrol; 2008; 42(5):472-80. PubMed ID: 18609287
[TBL] [Abstract][Full Text] [Related]
16. Comparison between slope-intercept and slope-only techniques for measuring glomerular filtration rate: use of two independent markers and an independent arbiter.
Bird NJ; Peters C; Michell AR; Peters AM
Nucl Med Commun; 2007 Sep; 28(9):711-8. PubMed ID: 17667750
[TBL] [Abstract][Full Text] [Related]
17. Comparison of plasma clearance of iohexol and urinary clearance of inulin for measurement of GFR in children.
Berg UB; Bäck R; Celsi G; Halling SE; Homberg I; Krmar RT; Monemi KÅ; Oborn H; Herthelius M
Am J Kidney Dis; 2011 Jan; 57(1):55-61. PubMed ID: 20870329
[TBL] [Abstract][Full Text] [Related]
18. Accuracy of iohexol plasma clearance for GFR-determination: a comparison between single and dual sampling.
Zhang Y; Sui Z; Yu Z; Li TF; Feng WY; Zuo L
BMC Nephrol; 2018 Jul; 19(1):174. PubMed ID: 29996810
[TBL] [Abstract][Full Text] [Related]
19. New sampling strategy using a Bayesian approach to assess iohexol clearance in kidney transplant recipients.
Benz-de Bretagne I; Le Guellec C; Halimi JM; Gatault P; Barbet C; Alnajjar A; Büchler M; Lebranchu Y; Andres CR; Vourcʼh P; Blasco H
Ther Drug Monit; 2012 Jun; 34(3):289-97. PubMed ID: 22585184
[TBL] [Abstract][Full Text] [Related]
20. Glomerular filtration rate estimated after multiple injections of contrast medium during angiography.
Boijsen M; Granerus G; Jacobsson L; Björneld L; Aurell M; Tylén U
Acta Radiol; 1988; 29(6):669-74. PubMed ID: 3142507
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]