These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
151 related articles for article (PubMed ID: 8672320)
21. Radial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery. Wagner JY; Sarwari H; Schön G; Kubik M; Kluge S; Reichenspurner H; Reuter DA; Saugel B Crit Care Med; 2015 Jul; 43(7):1423-8. PubMed ID: 25844700 [TBL] [Abstract][Full Text] [Related]
22. Calculated versus measured oxygen consumption during aortic surgery: reliability of the Fick method. Pestaña D; Garcia-de-Lorenzo A Anesth Analg; 1994 Feb; 78(2):253-6. PubMed ID: 8311276 [TBL] [Abstract][Full Text] [Related]
23. Reliability of cardiac output calculation by the fick principle and central venous oxygen saturation in emergency conditions. Weinbroum AA; Biderman P; Soffer D; Klausner JM; Szold O J Clin Monit Comput; 2008 Oct; 22(5):361-6. PubMed ID: 18946716 [TBL] [Abstract][Full Text] [Related]
24. Comparison between measured and fick-derived values of hemodynamic and oxymetric variables in patients with acute myocardial infarction. Pomés Iparraguirre H; Giniger R; Garber VA; Quiroga E; Jorge MA Am J Med; 1988 Sep; 85(3):349-52. PubMed ID: 3414730 [TBL] [Abstract][Full Text] [Related]
25. Cardiac output measurement by pulse dye densitometry: a comparison with the Fick's principle and thermodilution method. Bremer F; Schiele A; Tschaikowsky K Intensive Care Med; 2002 Apr; 28(4):399-405. PubMed ID: 11967592 [TBL] [Abstract][Full Text] [Related]
26. Comparison of oxygen consumption measurements: indirect calorimetry versus the reversed Fick method. Smithies MN; Royston B; Makita K; Konieczko K; Nunn JF Crit Care Med; 1991 Nov; 19(11):1401-6. PubMed ID: 1935161 [TBL] [Abstract][Full Text] [Related]
27. Indirect Calorimetry Overestimates Oxygen Consumption in Young Children: Caution is Advised Using Direct Fick Method as a Reference Method in Cardiac Output Comparison Studies. Sigurdsson TS; Lindberg L Pediatr Cardiol; 2020 Jan; 41(1):149-154. PubMed ID: 31741015 [TBL] [Abstract][Full Text] [Related]
28. Comparison of indirect calorimetry and thermodilution cardiac output measurement in children. Capderou A; Douguet D; Losay J; Zelter M Am J Respir Crit Care Med; 1997 Jun; 155(6):1930-4. PubMed ID: 9196098 [TBL] [Abstract][Full Text] [Related]
29. Feasibility of continuous oxygen delivery and cardiac output measurement by application of the Fick principle. Feustel PJ; Perkins RJ; Oppenlander JE; Stratton HH; Cohen IL Am J Respir Crit Care Med; 1994 Mar; 149(3 Pt 1):751-8. PubMed ID: 8118646 [TBL] [Abstract][Full Text] [Related]
30. Comparison of a modified Fick method with thermodilution for determining cardiac output in critically ill patients on mechanical ventilation. Lynch J; Kaemmerer H Intensive Care Med; 1990; 16(4):248-51. PubMed ID: 2358558 [TBL] [Abstract][Full Text] [Related]
31. Measured Oxygen Consumption During Pediatric Cardiac Catheterization is More Accurate than Assumed Oxygen Consumption. Ralston BH; Waberski AT; Kanter JP; Schick JW; Downing TE Pediatr Cardiol; 2024 Oct; 45(7):1466-1474. PubMed ID: 37243747 [TBL] [Abstract][Full Text] [Related]
32. Perioperative estimations of oxygen consumption from LiDCO™plus-derived cardiac output and Ca-cvO2 difference: Relationship with measurements by indirect calorimetry in elderly patients undergoing major abdominal surgery. Jakobsson J; Norén C; Hagel E; Backheden M; Kalman S; Bartha E PLoS One; 2024; 19(7):e0272239. PubMed ID: 39052563 [TBL] [Abstract][Full Text] [Related]
33. O2 consumption by the fick method. Methodologic factors. Chioléro R; Mavrocordatos P; Bracco D; Schutz Y; Cayeux C; Revelly JP Am J Respir Crit Care Med; 1994 May; 149(5):1118-22. PubMed ID: 8173750 [TBL] [Abstract][Full Text] [Related]
34. [Measuring cardiac output in infants with the Fick principle via oxygen consumption: animal experiment and clinical results]. Pscheidl E; Buheitel G; Schywalsky M; Braun GG Klin Padiatr; 1994; 206(2):86-91. PubMed ID: 8196312 [TBL] [Abstract][Full Text] [Related]
35. Oxygen consumption after cardiopulmonary bypass--implications of different measuring methods. Oudemans-van Straaten HM; Scheffer GJ; Eysman L; Wildevuur CR Intensive Care Med; 1993; 19(2):105-10. PubMed ID: 8486864 [TBL] [Abstract][Full Text] [Related]
36. Cardiac output measurement by bioimpedance and noninvasive pulse contour analysis compared with the continuous pulmonary artery thermodilution technique. Maass SW; Roekaerts PM; Lancé MD J Cardiothorac Vasc Anesth; 2014 Jun; 28(3):534-9. PubMed ID: 24746334 [TBL] [Abstract][Full Text] [Related]
37. [Measurement of cardiac output after cardiac surgery: validation of a partial carbon dioxide rebreathing (NICO) system in comparison with continuous thermodilution with a pulmonary artery catheter]. Jover JL; Soro M; Belda FJ; Aguilar G; Caro P; Ferrandis R Rev Esp Anestesiol Reanim; 2005 May; 52(5):256-62. PubMed ID: 15968903 [TBL] [Abstract][Full Text] [Related]
38. Measurement of cardiac output by automated single-breath technique, and comparison with thermodilution and Fick methods in patients with cardiac disease. Zenger MR; Brenner M; Haruno M; Mahon D; Wilson AF Am J Cardiol; 1993 Jan; 71(1):105-9. PubMed ID: 8420224 [TBL] [Abstract][Full Text] [Related]
39. Continuous Fick cardiac output compared to thermodilution cardiac output. Davies GG; Jebson PJ; Glasgow BM; Hess DR Crit Care Med; 1986 Oct; 14(10):881-5. PubMed ID: 3757528 [TBL] [Abstract][Full Text] [Related]
40. Cardiac output determination in children: equivalence of the transpulmonary thermodilution method to the direct Fick principle. Pauli C; Fakler U; Genz T; Hennig M; Lorenz HP; Hess J Intensive Care Med; 2002 Jul; 28(7):947-52. PubMed ID: 12122535 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]