76 related articles for article (PubMed ID: 8672662)
21. Range of motion in total knee arthroplasty. A computer analysis.
Walker PS; Garg A
Clin Orthop Relat Res; 1991 Jan; (262):227-35. PubMed ID: 1984921
[TBL] [Abstract][Full Text] [Related]
22. In vivo kinematics of mobile-bearing knee arthroplasty in deep knee bending motion.
Watanabe T; Yamazaki T; Sugamoto K; Tomita T; Hashimoto H; Maeda D; Tamura S; Ochi T; Yoshikawa H
J Orthop Res; 2004 Sep; 22(5):1044-9. PubMed ID: 15304277
[TBL] [Abstract][Full Text] [Related]
23. EOS orthopaedic imaging system to study patellofemoral kinematics: assessment of uncertainty.
Azmy C; Guérard S; Bonnet X; Gabrielli F; Skalli W
Orthop Traumatol Surg Res; 2010 Feb; 96(1):28-36. PubMed ID: 20170853
[TBL] [Abstract][Full Text] [Related]
24. Is greater than 145{degrees} of deep knee flexion under weight-bearing conditions safe after total knee arthroplasty?: a fluoroscopic analysis of Japanese-style deep knee flexion.
Niki Y; Takeda Y; Udagawa K; Enomoto H; Toyama Y; Suda Y
Bone Joint J; 2013 Jun; 95-B(6):782-7. PubMed ID: 23723272
[TBL] [Abstract][Full Text] [Related]
25. The morphology of the articular surfaces of biological knee joints provides essential guidance for the construction of functional knee endoprostheses.
Nägerl H; Dathe H; Fiedler C; Gowers L; Kirsch S; Kubein-Meesenburg D; Dumont C; Wachowski MM
Acta Bioeng Biomech; 2015; 17(2):45-53. PubMed ID: 26400423
[TBL] [Abstract][Full Text] [Related]
26. Fluoroscopic analyses of cruciate-retaining and medial pivot knee implants.
Schmidt R; Komistek RD; Blaha JD; Penenberg BL; Maloney WJ
Clin Orthop Relat Res; 2003 May; (410):139-47. PubMed ID: 12771824
[TBL] [Abstract][Full Text] [Related]
27. Optimization of the geometry of total knee implant in the sagittal plane using FEA.
Dargahi J; Najarian S; Amiri S
Biomed Mater Eng; 2003; 13(4):439-49. PubMed ID: 14646058
[TBL] [Abstract][Full Text] [Related]
28. The effects of patellar thickness on patellofemoral forces after resurfacing.
Star MJ; Kaufman KR; Irby SE; Colwell CW
Clin Orthop Relat Res; 1996 Jan; (322):279-84. PubMed ID: 8542705
[TBL] [Abstract][Full Text] [Related]
29. [Bone morphing system for rotational alignment in total knee arthroplasty].
Wu H; van Driessche S; Goutallier D
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jan; 22(1):12-5. PubMed ID: 18361228
[TBL] [Abstract][Full Text] [Related]
30. Knee motion in total knee arthroplasty. A roentgen stereophotogrammetric analysis of the kinematics of the Tricon-M knee prosthesis.
Nilsson KG; Kärrholm J; Ekelund L
Clin Orthop Relat Res; 1990 Jul; (256):147-61. PubMed ID: 2364604
[TBL] [Abstract][Full Text] [Related]
31. [Fabrication of custom-made artificial semi-knee joint based on rapid prototyping technique: computer-assisted design and manufacturing].
Wang Z; Teng Y; Li D
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2004 Sep; 18(5):347-51. PubMed ID: 15460040
[TBL] [Abstract][Full Text] [Related]
32. 2-D-3-D frequency registration using a low-dose radiographic system for knee motion estimation.
Jerbi T; Burdin V; Leboucher J; Stindel E; Roux C
IEEE Trans Biomed Eng; 2013 Mar; 60(3):813-20. PubMed ID: 22361657
[TBL] [Abstract][Full Text] [Related]
33. Personalised pose estimation from single-plane moving fluoroscope images using deep convolutional neural networks.
Vogl F; Schütz P; Postolka B; List R; Taylor W
PLoS One; 2022; 17(6):e0270596. PubMed ID: 35749482
[TBL] [Abstract][Full Text] [Related]
34. Kinematics of mobile-bearing total knee arthroplasty.
Dennis DA; Komistek RD
Instr Course Lect; 2005; 54():207-20. PubMed ID: 15948448
[TBL] [Abstract][Full Text] [Related]
35. Accuracy of a contour-based biplane fluoroscopy technique for tracking knee joint kinematics of different speeds.
Giphart JE; Zirker CA; Myers CA; Pennington WW; LaPrade RF
J Biomech; 2012 Nov; 45(16):2935-8. PubMed ID: 23021610
[TBL] [Abstract][Full Text] [Related]
36. In vivo comparison of knee kinematics before and after high-flexion posterior cruciate-retaining total knee arthroplasty.
Kitagawa A; Tsumura N; Chin T; Gamada K; Banks SA; Kurosaka M
J Arthroplasty; 2010 Sep; 25(6):964-9. PubMed ID: 19729277
[TBL] [Abstract][Full Text] [Related]
37. Influence of post-cam design of posterior stabilized knee prosthesis on tibiofemoral motion during high knee flexion.
Lin KJ; Huang CH; Liu YL; Chen WC; Chang TW; Yang CT; Lai YS; Cheng CK
Clin Biomech (Bristol, Avon); 2011 Oct; 26(8):847-52. PubMed ID: 21546143
[TBL] [Abstract][Full Text] [Related]
38. Fully automated software to monitor wear in prosthetic knees using fluoroscopic images.
Duryea J; Grainger AJ; Hide IG; Genant HK; Campbell RS
Eur Radiol; 2001; 11(11):2184-7. PubMed ID: 11702158
[TBL] [Abstract][Full Text] [Related]
39. Error performances of a model-based biplane fluoroscopic system for tracking knee prosthesis during treadmill gait task.
Barré A; Aminian K
Med Biol Eng Comput; 2018 Feb; 56(2):307-316. PubMed ID: 28726074
[TBL] [Abstract][Full Text] [Related]
40. Precision assessment of model-based RSA for a total knee prosthesis in a biplanar set-up.
Trozzi C; Kaptein BL; Garling EH; Shelyakova T; Russo A; Bragonzoni L; Martelli S
Knee; 2008 Oct; 15(5):396-402. PubMed ID: 18635360
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]