These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 8676231)

  • 1. Analysis of reconstruction of mandibular defects using single stainless steel A-O reconstruction plates.
    Ueyama Y; Naitoh R; Yamagata A; Matsumura T
    J Oral Maxillofac Surg; 1996 Jul; 54(7):858-62; discussion 862-3. PubMed ID: 8676231
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Primary mandibular reconstruction: analysis of 64 cases and evaluation of interface radiation dosimetry on bridging plates.
    Gullane PJ
    Laryngoscope; 1991 Jun; 101(6 Pt 2 Suppl 54):1-24. PubMed ID: 2041453
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The use of stabilization plates in the immediate repair of defects following mandibular resection.
    Murphy JB; Weisman RA; Kent K
    Oral Surg Oral Med Oral Pathol; 1989 Oct; 68(4):380-4. PubMed ID: 2797734
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fracture of mandibular reconstruction plates used after tumor resection.
    Shibahara T; Noma H; Furuya Y; Takaki R
    J Oral Maxillofac Surg; 2002 Feb; 60(2):182-5. PubMed ID: 11815918
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Analysis of complications after reconstruction of bone defects involving complete mandibular resection using finite element modelling.
    Markwardt J; Pfeifer G; Eckelt U; Reitemeier B
    Onkologie; 2007 Mar; 30(3):121-6. PubMed ID: 17341898
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Experience with AO reconstruction plates after partial mandibular resection involving its continuity.
    Freitag V; Hell B; Fischer H
    J Craniomaxillofac Surg; 1991 Jul; 19(5):191-8. PubMed ID: 1894736
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rigid fixation of vascularized bone grafts in mandibular reconstruction.
    Futran ND; Urken ML; Buchbinder D; Moscoso JF; Biller HF
    Arch Otolaryngol Head Neck Surg; 1995 Jan; 121(1):70-6. PubMed ID: 7803025
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Assessment of plate use for mandibular reconstruction: has changing technology made a difference?
    Klotch DW; Gal TJ; Gal RL
    Otolaryngol Head Neck Surg; 1999 Oct; 121(4):388-92. PubMed ID: 10504593
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Volume-length impact of lateral jaw resections on complication rates.
    Arden RL; Rachel JD; Marks SC; Dang K
    Arch Otolaryngol Head Neck Surg; 1999 Jan; 125(1):68-72. PubMed ID: 9932591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mandibular reconstruction using a titanium plate: the impact of radiation therapy on plate preservation.
    Ryu JK; Stern RL; Robinson MG; Bowers MK; Kubo HD; Donald PJ; Rosenthal SA; Fu KK
    Int J Radiat Oncol Biol Phys; 1995 Jun; 32(3):627-34. PubMed ID: 7790248
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Advantages of mandibular reconstruction with the titanium hollow screw osseointegrating reconstruction plate (THORP).
    Koch WM; Yoo GH; Goodstein ML; Eisele DW; Richtsmeier WJ; Price JC
    Laryngoscope; 1994 May; 104(5 Pt 1):545-52. PubMed ID: 8189984
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Factors involved in long- and short-term mandibular plate exposure.
    Nicholson RE; Schuller DE; Forrest LA; Mountain RE; Ali T; Young D
    Arch Otolaryngol Head Neck Surg; 1997 Feb; 123(2):217-22. PubMed ID: 9046293
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Long-term stability of two different mandibular bridging systems.
    Söderholm AL; Hallikainen D; Lindqvist C
    Arch Otolaryngol Head Neck Surg; 1993 Sep; 119(9):1031-6. PubMed ID: 8357585
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Plate related complication after mandibular reconstruction].
    Liu SP; Cai ZG; Zhang J; Zhang JG; Zhang Y
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2013 Oct; 48(10):586-90. PubMed ID: 24438564
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical Study of Reconstruction Plates Used in the Surgery for Mandibular Discontinuity Defect.
    Kawasaki G; Imayama N; Yoshitomi I; Furukawa K; Umeda M
    In Vivo; 2019; 33(1):191-194. PubMed ID: 30587622
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Long-term complications associated with immediate plate reconstruction for mandibular defect following tumor-surgery].
    Zhang Y; Zhang J; Yu G
    Zhonghua Kou Qiang Yi Xue Za Zhi; 1999 Jul; 34(4):205-7. PubMed ID: 11776905
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Mandibular reconstruction with the titanium hollow screw reconstruction plate (THORP) system: evaluation of 62 cases.
    Vuillemin T; Raveh J; Sutter F
    Plast Reconstr Surg; 1988 Nov; 82(5):804-14. PubMed ID: 3174870
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rigid reconstruction plates for immediate reconstruction following mandibular resection for malignant tumors.
    Lindqvist C; Söderholm AL; Laine P; Paatsama J
    J Oral Maxillofac Surg; 1992 Nov; 50(11):1158-63. PubMed ID: 1403270
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study of locking plates in mandibular reconstruction after ablative tumor surgery: THORP versus UniLOCK system.
    Gellrich NC; Suarez-Cunqueiro MM; Otero-Cepeda XL; Schön R; Schmelzeisen R; Gutwald R
    J Oral Maxillofac Surg; 2004 Feb; 62(2):186-93. PubMed ID: 14762751
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A small number of residual teeth after the mandibular resection of oral cancer is associated with titanium reconstruction plate exposure.
    Hirohata H; Yanagawa T; Takaoka S; Yamagata K; Sasaki K; Shibuya Y; Uchida F; Fukuzawa S; Tabuchi K; Hasegawa S; Ishibashi-Kanno N; Sekido M; Bukawa H
    Clin Exp Dent Res; 2019 Oct; 5(5):469-475. PubMed ID: 31687179
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.