These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

179 related articles for article (PubMed ID: 8678248)

  • 1. A comparison of the stress response to laryngoscopy. The Macintosh versus the McCoy blade.
    McCoy EP; Mirakhur RK; McCloskey BV
    Anaesthesia; 1995 Nov; 50(11):943-6. PubMed ID: 8678248
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Which laryngoscope is the most stressful in laryngoscopy; Macintosh, Miller, or McCoy?].
    Nishiyama T; Higashizawa T; Bito H; Konishi A; Sakai T
    Masui; 1997 Nov; 46(11):1519-24. PubMed ID: 9404140
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Opioid sparing during endotracheal intubation using McCoy laryngoscope in neurosurgical patients: the comparison of haemodynamic changes with Macintosh blade in a randomized trial.
    Tewari P; Gupta D; Kumar A; Singh U
    J Postgrad Med; 2005; 51(4):260-4; discussion 264-5. PubMed ID: 16388166
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of the forces exerted during laryngoscopy. The Macintosh versus the McCoy blade.
    McCoy EP; Mirakhur RK; Rafferty C; Bunting H; Austin BA
    Anaesthesia; 1996 Oct; 51(10):912-5. PubMed ID: 8984862
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison between the Macintosh and the McCoy laryngoscope blades.
    Cook TM; Tuckey JP
    Anaesthesia; 1996 Oct; 51(10):977-80. PubMed ID: 8984878
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Skin vasomotor reflex induced by laryngoscopy: comparison of the McCoy and Macintosh blades.
    Shimoda O; Ikuta Y; Isayama S; Sakamoto M; Terasaki H
    Br J Anaesth; 1997 Dec; 79(6):714-8. PubMed ID: 9496201
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Hemodynamic response to intubation with Macintosh and McCoy blades].
    Román J; Beltrán de Heredia B; García-Velasco P; Parramón F; García R; Vilaplana J; Villalonga A
    Rev Esp Anestesiol Reanim; 1996 May; 43(5):177-9. PubMed ID: 8753922
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Determination of the distance between the upper incisors and the laryngoscope blade during laryngoscopy: comparisons of the McCoy, the Macintosh, the Miller, and the Belscope blades].
    Bito H; Nishiyama T; Higarhizawa T; Sakai T; Konishi A
    Masui; 1998 Oct; 47(10):1257-61. PubMed ID: 9834604
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of tracheal intubation with the McCoy or Macintosh laryngoscope on the blood pressure and heart rate during propofol-remifentanil induction.
    Shin HJ; Shin YD; Kim ST
    Korean J Anesthesiol; 2009 Apr; 56(4):387-391. PubMed ID: 30625758
    [TBL] [Abstract][Full Text] [Related]  

  • 10. View of the larynx obtained using the Miller blade and paraglossal approach, compared to that with the Macintosh blade.
    Achen B; Terblanche OC; Finucane BT
    Anaesth Intensive Care; 2008 Sep; 36(5):717-21. PubMed ID: 18853593
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The McCoy straight blade does not improve laryngoscopy and intubation in normal infants.
    Iohom G; Franklin R; Casey W; Lyons B
    Can J Anaesth; 2004 Feb; 51(2):155-9. PubMed ID: 14766692
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new mirrored laryngoscope.
    McMorrow RC; Mirakhur RK
    Anaesthesia; 2003 Oct; 58(10):998-1002. PubMed ID: 12969041
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A randomised comparative study of the effect of Airtraq optical laryngoscope vs. Macintosh laryngoscope on intraocular pressure in non-ophthalmic surgery.
    Das B; Samal RK; Ghosh A; Kundu R
    Braz J Anesthesiol; 2016; 66(1):19-23. PubMed ID: 26768925
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation.
    Shribman AJ; Smith G; Achola KJ
    Br J Anaesth; 1987 Mar; 59(3):295-9. PubMed ID: 3828177
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Tracheal intubation with the PENTAX-AWS (airway scope) reduces changes of hemodynamic responses and bispectral index scores compared with the Macintosh laryngoscope.
    Nishikawa K; Matsuoka H; Saito S
    J Neurosurg Anesthesiol; 2009 Oct; 21(4):292-6. PubMed ID: 19955890
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of two Macintosh laryngoscope blades in 300 patients.
    Asai T; Matsumoto S; Fujise K; Johmura S; Shingu K
    Br J Anaesth; 2003 Apr; 90(4):457-60. PubMed ID: 12644417
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of laryngoscope types on hemodynamic response and optic nerve sheath diameter. McCoy, Macintosh, and C-MAC video-laryngoscope.
    Küçükosman G; Aydın BG; Gülçek N; Okyay RD; Pişkin Ö; Ayoğlu H
    Saudi Med J; 2020 Sep; 41(9):930-937. PubMed ID: 32893274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes.
    Haidry MA; Khan FA
    J Anaesthesiol Clin Pharmacol; 2013 Apr; 29(2):196-9. PubMed ID: 23878441
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Cardio-circulatory response to laryngoscopy. Comparative study between Macintosh and McCoy laryngoscopes].
    Castillo J; Castaño J; Escolano F; Arilla M
    Rev Esp Anestesiol Reanim; 1996; 43(6):219-21. PubMed ID: 8756238
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparison of the Truview blade with the Macintosh blade in adult patients.
    Barak M; Philipchuck P; Abecassis P; Katz Y
    Anaesthesia; 2007 Aug; 62(8):827-31. PubMed ID: 17635433
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.