These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 8678359)

  • 1. Dynamic model of oxygen transport for transcutaneous PO2 analysis.
    Talbot A; Neuman MR; Saidel GM; Jacobsen E
    Ann Biomed Eng; 1996; 24(2):294-304. PubMed ID: 8678359
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimation of the determinants of transcutaneous oxygen tension using a dynamic computer model.
    Talbot-Pedersen A; Neuman MR; Saidel GM; Jacobsen E
    Adv Exp Med Biol; 1987; 220():269-73. PubMed ID: 3673772
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Blood flow rate, temperature, oxygen tension and consumption in the skin of adults measured by a heated microcathode oxygen electrode.
    Jaszczak P
    Dan Med Bull; 1988 Aug; 35(4):322-34. PubMed ID: 3048920
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A topical metabolic inhibitor to improve transcutaneous estimation of arterial oxygen tension in adults.
    Patel BT; Delpy DT; Hillson PJ; Parker D
    J Biomed Eng; 1989 Sep; 11(5):381-3. PubMed ID: 2796316
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The use of the Hellige Oxymonitor to study skin blood flow changes.
    Gaylarde PM; Sarkany I
    Adv Exp Med Biol; 1987; 220():241-6. PubMed ID: 3673769
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous monitoring of interstitial tissue oxygen using subcutaneous oxygen microsensors: In vivo characterization in healthy volunteers.
    Kanick SC; Schneider PA; Klitzman B; Wisniewski NA; Rebrin K
    Microvasc Res; 2019 Jul; 124():6-18. PubMed ID: 30742844
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Wearable, Luminescent Oxygen Sensor for Transcutaneous Oxygen Monitoring.
    Lim CJ; Lee S; Kim JH; Kil HJ; Kim YC; Park JW
    ACS Appl Mater Interfaces; 2018 Dec; 10(48):41026-41034. PubMed ID: 30404434
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Evaluation of transcutaneous oxygen pressure in adults with respiratory pathology].
    Herrejón A; Simó M; Chiner E; Pérez ME; Marín J
    Rev Esp Fisiol; 1989 Jun; 45(2):123-6. PubMed ID: 2772389
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evaluation of factors affecting relationship between transcutaneous PO2 and probe temperature.
    Grønlund J
    J Appl Physiol (1985); 1985 Oct; 59(4):1117-27. PubMed ID: 4055591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is transcutaneous PO2 monitoring during exercise a reliable alternative to arterial PO2 measurements?
    Brudin L; Berg S; Ekberg P; Castenfors J
    Clin Physiol; 1994 Jan; 14(1):47-52. PubMed ID: 8149709
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Examinations on the blood flow dependence of tcPO2 using the model of the "circulatory hyperbola".
    Steinacker JM; Spittelmeister W; Wodick R
    Adv Exp Med Biol; 1987; 220():263-8. PubMed ID: 2960140
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia.
    Nishiyama T; Nakamura S; Yamashita K
    Eur J Anaesthesiol; 2006 Dec; 23(12):1049-54. PubMed ID: 16824244
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Age-related changes in microvascular blood flow and transcutaneous oxygen tension under Basal and stimulated conditions.
    Ogrin R; Darzins P; Khalil Z
    J Gerontol A Biol Sci Med Sci; 2005 Feb; 60(2):200-6. PubMed ID: 15814863
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Transcutaneous PO2 measurement.
    Tremper KK
    Can Anaesth Soc J; 1984 Nov; 31(6):664-77. PubMed ID: 6388743
    [TBL] [Abstract][Full Text] [Related]  

  • 15. In vivo calibration of a transcutaneous oxygen electrode in adult patients.
    Gray BJ; Heaton RW; Henderson A; Hutchison DC
    Adv Exp Med Biol; 1987; 220():75-7. PubMed ID: 3673788
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Long-term transcutaneous monitoring of oxygen tension and carbon dioxide at 42 degrees C in critically ill neonates: improved performance of the tcpo2 monitor with topical metabolic inhibition.
    Fanconi S; Tschupp A; Molinari L
    Eur J Pediatr; 1996 Dec; 155(12):1043-6. PubMed ID: 8956942
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transcutaneous pO2 imaging during tourniquet-induced forearm ischemia using planar optical oxygen sensors.
    Babilas P; Lamby P; Prantl L; Schreml S; Jung EM; Liebsch G; Wolfbeis OS; Landthaler M; Szeimies RM; Abels C
    Skin Res Technol; 2008 Aug; 14(3):304-11. PubMed ID: 19159376
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The validity of the transcutaneous oxygen tension method in adults.
    Rooth G; Hedstrand U; Tydén H; Ogren C
    Crit Care Med; 1976; 4(3):162-5. PubMed ID: 939109
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transcutaneous oxygen tension during exercise in patients with pulmonary emphysema.
    Hutchison DC; Gray BJ; Callaghan JM; Heaton RW
    Adv Exp Med Biol; 1987; 220():67-70. PubMed ID: 3673786
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous monitoring of oxygen tension with a transcutaneous sensor during hypotensive anesthesia.
    Megerman J; Mihelakos PT; Katsamouris AN; Fahmy NR; Lappas DG; Abbott WM
    Acta Anaesthesiol Scand; 1987 Jan; 31(1):25-9. PubMed ID: 3103366
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.