These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
108 related articles for article (PubMed ID: 8685322)
1. Diffuse infiltrative lung disease: clinical value of sliding-thin-slab maximum intensity projection CT scans in the detection of mild micronodular patterns. Remy-Jardin M; Remy J; Artaud D; Deschildre F; Duhamel A Radiology; 1996 Aug; 200(2):333-9. PubMed ID: 8685322 [TBL] [Abstract][Full Text] [Related]
2. Can maximum intensity projection images with multidetector-row computed tomography help to differentiate between the micronodular distribution of focal and diffuse infiltrative lung diseases? Sakai M; Murayama S; Gibo M; Akamine T; Yoshinaga M; Iraha S; Nagata O J Comput Assist Tomogr; 2005; 29(5):588-91. PubMed ID: 16163024 [TBL] [Abstract][Full Text] [Related]
3. Sliding thin slab, minimum intensity projection technique in the diagnosis of emphysema: histopathologic-CT correlation. Remy-Jardin M; Remy J; Gosselin B; Copin MC; Wurtz A; Duhamel A Radiology; 1996 Sep; 200(3):665-71. PubMed ID: 8756912 [TBL] [Abstract][Full Text] [Related]
4. CT angiography for evaluation of living renal donors: comparison of four reconstruction methods. Kim JK; Kim JH; Bae SJ; Cho KS AJR Am J Roentgenol; 2004 Aug; 183(2):471-7. PubMed ID: 15269043 [TBL] [Abstract][Full Text] [Related]
5. Diffuse lung disease: assessment with helical CT--preliminary observations of the role of maximum and minimum intensity projection images. Bhalla M; Naidich DP; McGuinness G; Gruden JF; Leitman BS; McCauley DI Radiology; 1996 Aug; 200(2):341-7. PubMed ID: 8685323 [TBL] [Abstract][Full Text] [Related]
7. Assessment of diffuse infiltrative lung disease: comparison of conventional CT and high-resolution CT. Remy-Jardin M; Remy J; Deffontaines C; Duhamel A Radiology; 1991 Oct; 181(1):157-62. PubMed ID: 1887026 [TBL] [Abstract][Full Text] [Related]
8. Effect of slab thickness on the CT detection of pulmonary nodules: use of sliding thin-slab maximum intensity projection and volume rendering. Kawel N; Seifert B; Luetolf M; Boehm T AJR Am J Roentgenol; 2009 May; 192(5):1324-9. PubMed ID: 19380557 [TBL] [Abstract][Full Text] [Related]
9. Low grade coal worker's pneumoconiosis. Comparison of CT and chest radiography. Gevenois PA; Pichot E; Dargent F; Dedeire S; Vande Weyer R; De Vuyst P Acta Radiol; 1994 Jul; 35(4):351-6. PubMed ID: 8011384 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of respiratory bronchiolitis nodules with maximum intensity projection images. Kızıloğlu HA; Beyhan M; Gökçe E Rev Assoc Med Bras (1992); 2023; 69(12):e20230297. PubMed ID: 37971118 [TBL] [Abstract][Full Text] [Related]
11. [Image analysis in multislice spiral CT of the lung with MPR and MIP reconstructions]. Eibel R; Brüning R; Schöpf UJ; Leimeister P; Stadie A; Reiser MF Radiologe; 1999 Nov; 39(11):952-7. PubMed ID: 10602800 [TBL] [Abstract][Full Text] [Related]
12. [Exploration of the early detection of lung parenchyma micronodules, nodule coalescence and emphysema by CT and HRCT in coal miners with and without coal-worker's pneumoconiosis evidence]. Ren HM; Xing JC; Yang LJ; Han WH; Yi WJ; Chen WH Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2012 Jan; 30(1):13-6. PubMed ID: 22730681 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of small pulmonary arteries by 16-slice multidetector computed tomography: Optimum slab thickness in condensing transaxial images converted into maximum intensity projection images. Jeong YJ; Lee KS; Yoon YC; Kim TS; Chung MJ; Kim S J Comput Assist Tomogr; 2004; 28(2):195-203. PubMed ID: 15091123 [TBL] [Abstract][Full Text] [Related]
14. Multi-detector row CT and postprocessing techniques in the assessment of diffuse lung disease. Beigelman-Aubry C; Hill C; Guibal A; Savatovsky J; Grenier PA Radiographics; 2005; 25(6):1639-52. PubMed ID: 16284140 [TBL] [Abstract][Full Text] [Related]
15. [Contribution of high-resolution volume computed tomography (HRVCT) for the exploration of diffuse pulmonary infiltrative disorders]. Vernhet H; Bousquet C; Vergnes C; Thiebault C; Lesnik A; Durand G; Giron J; Senac JP Rev Mal Respir; 1999 Apr; 16(2):188-97. PubMed ID: 10339762 [TBL] [Abstract][Full Text] [Related]
16. [High-resolution volumetric computerized tomography of the lung: optimization of technique and image quality as a function of its clinical-diagnostic use and dose to the patient]. Gavelli G; Giampalma E; Cenni M; Pierotti L; Cavina M; Bergamini C Radiol Med; 1998 Apr; 95(4):322-8. PubMed ID: 9676210 [TBL] [Abstract][Full Text] [Related]
17. STS-MIP: a new reconstruction technique for CT of the chest. Napel S; Rubin GD; Jeffrey RB J Comput Assist Tomogr; 1993; 17(5):832-8. PubMed ID: 8370848 [TBL] [Abstract][Full Text] [Related]
18. Detection of pulmonary nodules at spiral CT: comparison of maximum intensity projection sliding slabs and single-image reporting. Diederich S; Lentschig MG; Overbeck TR; Wormanns D; Heindel W Eur Radiol; 2001; 11(8):1345-50. PubMed ID: 11519541 [TBL] [Abstract][Full Text] [Related]
19. Multidetector CT detection of peritoneal metastases: evaluation of sensitivity between standard 2.5 mm axial imaging and maximum-intensity-projection (MIP) reconstructions. Jensen CT; Vicens-Rodriguez RA; Wagner-Bartak NA; Fox PS; Faria SC; Carrion I; Qayyum A; Tamm EP Abdom Imaging; 2015 Oct; 40(7):2167-72. PubMed ID: 25666971 [TBL] [Abstract][Full Text] [Related]
20. Value of sliding-thin-slab maximum intensity projections in imaging of the auditory ossicles. Jingzhen H; Cheng L; Bin Z; Guangbin W; Daocai W; Junping Z J Comput Assist Tomogr; 2008; 32(1):141-5. PubMed ID: 18303303 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]