These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
102 related articles for article (PubMed ID: 8687305)
1. A proposal for a theory and detection method of cavitation potential of mitral bileaflet heart valve. Zhang Z; Ye CX; Wang YS Artif Organs; 1995 Sep; 19(9):952-4. PubMed ID: 8687305 [TBL] [Abstract][Full Text] [Related]
2. Effect of structural compliance on cavitation threshold measurement of mechanical heart valves. Guo GX; Adlparvar P; Howanec M; Roy J; Kafesjian R; Kingsbury C J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S77-83; discussion S83-4. PubMed ID: 8061872 [TBL] [Abstract][Full Text] [Related]
3. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity. Lee H; Homma A; Taenaka Y Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477 [TBL] [Abstract][Full Text] [Related]
4. In vitro observations of mechanical heart valve cavitation. Shu MC; Leuer LH; Armitage TL; Schneider TE; Christiansen DR J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S85-92; discussion S92-3. PubMed ID: 8061874 [TBL] [Abstract][Full Text] [Related]
5. Pressure field in the vicinity of mechanical valve occluders at the instant of valve closure: correlation with cavitation initiation. Chandran KB; Lee CS; Chen LD J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S65-75; discussion S75-6. PubMed ID: 8061871 [TBL] [Abstract][Full Text] [Related]
7. In-vivo prediction of cavitation near a Medtronic Hall valve. Johansen P; Andersen TS; Hasenkam JM; Nygaard H J Heart Valve Dis; 2004 Jul; 13(4):651-8. PubMed ID: 15311874 [TBL] [Abstract][Full Text] [Related]
8. Estimation of mechanical heart valve cavitation in a pneumatic ventricular assist device. Lee H; Akagawa E; Homma A; Tsukiya T; Tatsumi E; Taenaka Y J Artif Organs; 2007; 10(3):181-5. PubMed ID: 17846718 [TBL] [Abstract][Full Text] [Related]
9. In vivo demonstration of cavitation potential of a mechanical heart valve. Dexter EU; Aluri S; Radcliffe RR; Zhu H; Carlson DD; Heilman TE; Chandran KB; Richenbacher WE ASAIO J; 1999; 45(5):436-41. PubMed ID: 10503622 [TBL] [Abstract][Full Text] [Related]
10. Cavitation potential of mechanical heart valve prostheses. Graf T; Fischer H; Reul H; Rau G Int J Artif Organs; 1991 Mar; 14(3):169-74. PubMed ID: 2045192 [TBL] [Abstract][Full Text] [Related]
11. A squeeze flow phenomenon at the closing of a bileaflet mechanical heart valve prosthesis. Bluestein D; Einav S; Hwang NH J Biomech; 1994 Nov; 27(11):1369-78. PubMed ID: 7798287 [TBL] [Abstract][Full Text] [Related]
12. Hydrodynamic function of tilting disc prostheses and bileaflet valves in double valve replacement. StrĂ¼ber M; Campbell A; Richard G; Laas J Eur J Cardiothorac Surg; 1996; 10(6):422-7. PubMed ID: 8817137 [TBL] [Abstract][Full Text] [Related]
13. Mechanism for cavitation of monoleaflet and bileaflet valves in an artificial heart. Lee H; Tatsumi E; Homma A; Tsukiya T; Taenaka Y J Artif Organs; 2006; 9(3):154-60. PubMed ID: 16998700 [TBL] [Abstract][Full Text] [Related]
14. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model. He Z; Xi B; Zhu K; Hwang NH J Heart Valve Dis; 2001 Sep; 10(5):666-74. PubMed ID: 11603607 [TBL] [Abstract][Full Text] [Related]
15. Cavitation damage of pyrolytic carbon in mechanical heart valves. Kafesjian R; Howanec M; Ward GD; Diep L; Wagstaff LS; Rhee R J Heart Valve Dis; 1994 Apr; 3 Suppl 1():S2-7. PubMed ID: 8061867 [TBL] [Abstract][Full Text] [Related]