These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 869157)

  • 1. Technical considerations in the use of the membrane oxygenator (Lande'-Edwards) for open heart surgery.
    Stacey RB; Wright JS; Fisk GC
    Anaesth Intensive Care; 1977 May; 5(2):134-9. PubMed ID: 869157
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Use of lande-edwards membrane oxygenators as artificial lungs].
    Vanderhoeft P; Derks C; de Francquen P; Sarezky M; Simpson R
    Acta Chir Belg; 1975 Jan; 74(1):82-5. PubMed ID: 1114875
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Total cardiopulmonary bypass with the Lande-Edwards membrane oxygenator.
    Baffes T; Patel K; Jegathesan S
    Am J Cardiol; 1972 May; 29(5):672-7. PubMed ID: 5021497
    [No Abstract]   [Full Text] [Related]  

  • 4. Some advantages of the membrane oxygenator for open-heart surgery.
    Wright JS; Fisk GC; Torda TA; Stacey RB; Hicks RG
    J Thorac Cardiovasc Surg; 1975 Jun; 69(6):884-90. PubMed ID: 1134114
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Landé-Edwards membrane oxygenator for heart surgery: method and oxygen transfer.
    Carlson RG; Landé AJ; Bailey C; Lillehei CW
    Mt Sinai J Med; 1973; 40(2):153-9. PubMed ID: 4540366
    [No Abstract]   [Full Text] [Related]  

  • 6. Clinical comparison between membrane and bubble oxygenators in cardiopulmonary bypass.
    Fenchel G; Seybold-Epting W; Schmidt K; Stunkat R; Hoffmeister HE
    J Cardiovasc Surg (Torino); 1979; 20(4):419-22. PubMed ID: 479280
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Landé-Edwards membrane oxygenator for total cardiopulmonary support in 110 patients during heart surgery.
    Carlson RG; Landé AJ; Ivey LA; Subramanian VA; Bloch JH; Rogos B; Landis B; Baxter J; Patterson RH; Lillehei CW
    Surgery; 1972 Dec; 72(6):913-9. PubMed ID: 4539001
    [No Abstract]   [Full Text] [Related]  

  • 8. Proceedings: Landé-Edwards membrane oxygenator for heart surgery and prolonged lung or heart support.
    Carlson RG
    N Y State J Med; 1973 Oct; 73(19):2351-8. PubMed ID: 4518791
    [No Abstract]   [Full Text] [Related]  

  • 9. A comparison of membrane and bubble oxygenation as used in cardiopulmonary bypass in patients. The importance of pericardial blood as a source of hemolysis.
    Siderys H; Herod GT; Halbrook H; Pittman JN; Rubush JL; Kasebaker V; Berry GR
    J Thorac Cardiovasc Surg; 1975 May; 69(5):708-12. PubMed ID: 1079293
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Landé-Edwards membrane oxygenator during heart surgery. Oxygen transfer, microemboli counts, and Bender-Gestalt visual motor test scores.
    Carlson RG; Landé AJ; Landis B; Rogoz B; Baxter J; Patterson RH; Stenzel K; Lillehei CW
    J Thorac Cardiovasc Surg; 1973 Dec; 66(6):894-905. PubMed ID: 4586304
    [No Abstract]   [Full Text] [Related]  

  • 11. High risk of intraoperative awareness during cardiopulmonary bypass with isoflurane administration via diffusion membrane oxygenators.
    Philipp A; Wiesenack C; Behr R; Schmid FX; Birnbaum DE
    Perfusion; 2002 May; 17(3):175-8. PubMed ID: 12017384
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Clinical use of membrane oxygenators for extended extracroporal circulation].
    Hoffmeister HE; Schorer R; Stunkat R
    Thoraxchir Vask Chir; 1975 Feb; 23(1):49-57. PubMed ID: 1079646
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pediatric application of Landé-Edwards membrane oxygenator. Continuous perfusion and hypothermic arrest techniques.
    Wright JS; McCulloch CH; Torda TA; Stacey R; Hicks RG
    J Thorac Cardiovasc Surg; 1973 Apr; 65(4):503-10. PubMed ID: 4697438
    [No Abstract]   [Full Text] [Related]  

  • 14. [Experimental evaluation of assisted extracorporeal circulation using Landé-Edwards membrane oxygenator for induced acute pulmonary insufficiency (author's transl)].
    Kaku R
    Nihon Geka Hokan; 1976 Mar; 45(2):123-33. PubMed ID: 988799
    [No Abstract]   [Full Text] [Related]  

  • 15. Use of a membrane oxygenator for open-heart surgery in infants.
    Murphy DA; Gillis DA; Lau H
    Can J Surg; 1976 Mar; 19(2):103-7. PubMed ID: 1260550
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effects of oxygenator and pumping devices on blood parameters in open heart surgery: a clinical study.
    Barlas S; Tireli E; Tekinalp H; Dayioğlu E; Sevgenay L; Barlas C
    Adv Exp Med Biol; 1996; 388():617-23. PubMed ID: 8798867
    [No Abstract]   [Full Text] [Related]  

  • 17. Elimination of sevoflurane is reduced in plasma-tight compared to conventional membrane oxygenators.
    Prasser C; Zelenka M; Gruber M; Philipp A; Keyser A; Wiesenack C
    Eur J Anaesthesiol; 2008 Feb; 25(2):152-7. PubMed ID: 17655810
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Extracorporeal membrane oxygenation treatment of a neonate with severe low cardiac output syndrome following open heart surgery].
    Lin R; Tan LH; Zhang ZW; Sun MY; Du LZ
    Zhonghua Er Ke Za Zhi; 2008 Jan; 46(1):26-9. PubMed ID: 18353234
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Landé-Edwards membrane oxygenator for heart surgery and respiratory support.
    Carlson RG; Landé AJ; Gannon P; Lillehei CW
    Nihon Kyobu Geka Gakkai Zasshi; 1973 May; 21(5):468-78. PubMed ID: 4737771
    [No Abstract]   [Full Text] [Related]  

  • 20. [Hemolysis caused by the Landé-Edwards membrane oxygenator].
    Horiuchi A
    Nihon Kyobu Geka Gakkai Zasshi; 1975 Sep; 23(9):1064-79. PubMed ID: 1238468
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.