These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 8694331)

  • 1. Obstruction due to retained carbon dioxide absorber canister wrapping.
    Norman PH; Daley MD; Walker JR; Fusetti S
    Anesth Analg; 1996 Aug; 83(2):425-6. PubMed ID: 8694331
    [No Abstract]   [Full Text] [Related]  

  • 2. Carbon dioxide absorber as a cause of high airway pressures.
    Bagdasarian LA; Shah NK; Sharif MK
    J Clin Anesth; 2008 Feb; 20(1):48-9. PubMed ID: 18346610
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Obstruction due to retained carbon dioxide absorber canister wrapping.
    Ransom ES; Norfleet EA
    Anesth Analg; 1997 Mar; 84(3):703. PubMed ID: 9052335
    [No Abstract]   [Full Text] [Related]  

  • 4. Bicycle tire inflator as carbon dioxide source for anesthesia apparatus checkout.
    Smith SE
    Anesth Analg; 2010 Mar; 110(3):974. PubMed ID: 20185677
    [No Abstract]   [Full Text] [Related]  

  • 5. Inadvertent disconnection of the carbon dioxide absorber canister of a Blease Frontline anaesthetic machine.
    Jeganathan C; Chandradeva K
    Anaesthesia; 2007 Jun; 62(6):638-9. PubMed ID: 17506760
    [No Abstract]   [Full Text] [Related]  

  • 6. Massive leak during manual ventilation: adjustable pressure limiting valve malfunction not detected by pre-anesthetic checkout.
    Vijayakumar A; Saxena DK; Sivan Pillay A; Darsow R
    Anesth Analg; 2010 Aug; 111(2):579-80; author reply 580. PubMed ID: 20664101
    [No Abstract]   [Full Text] [Related]  

  • 7. A potential hazard involving the gas sampling line and the adjustable pressure limiting valve on the Drager Apollo Anesthesia Workstation.
    Robards C; Corda D
    Anesth Analg; 2010 Aug; 111(2):578-9; author reply 580. PubMed ID: 20664099
    [No Abstract]   [Full Text] [Related]  

  • 8. [Cleft in carbon dioxide absorber. Intraoperative problems with ventilation due to a leak in the breathing circuit].
    Paul C; Böttiger BW
    Anaesthesist; 2010 Jul; 59(7):652-4. PubMed ID: 20574760
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Circuit leak from capnograph sampling line lodged under adjustable pressure limiting valve.
    Hennenfent S; Suslowicz B
    Anesth Analg; 2010 Aug; 111(2):578; author reply 580. PubMed ID: 20664100
    [No Abstract]   [Full Text] [Related]  

  • 10. Humphrey ADE disposable carbon dioxide absorber.
    Scott PV
    Anaesthesia; 1998 Aug; 53(8):829-30. PubMed ID: 9797543
    [No Abstract]   [Full Text] [Related]  

  • 11. Gas leak due to a damaged GE Disposable Multi Absorber Canister used with an EZchange Module following its reinstallation during anesthesia.
    Sano H; Suzuki T; Kaneda Y
    Can J Anaesth; 2015 Jan; 62(1):96-7. PubMed ID: 25326266
    [No Abstract]   [Full Text] [Related]  

  • 12. Pre-use testing of coaxial circuits: the perils of Pethick.
    Beauprie IG; Clark AG; Keith IC; Spence D
    Can J Anaesth; 1990 May; 37(4 Pt 2):S103. PubMed ID: 2113836
    [No Abstract]   [Full Text] [Related]  

  • 13. Detection of faulty CO2 absorber by capnography.
    Riley RH; Harris LA; Hale AP; Dockar G
    Anaesth Intensive Care; 1992 May; 20(2):246. PubMed ID: 1595865
    [No Abstract]   [Full Text] [Related]  

  • 14. Baby EAR circuit: a clinical determination of optimal fresh gas flow in spontaneous breathing anesthesia.
    Theerapongpakdee S; Bunsangjaroen P; Horatanaruang D; Phanpanusit T; Asava-aree C; Uppan K
    J Med Assoc Thai; 2010 Nov; 93(11):1284-7. PubMed ID: 21114207
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance characteristics of a 'to and fro' disposable soda lime canister.
    Shaw M; Scott DH
    Anaesthesia; 1998 May; 53(5):454-60. PubMed ID: 9659018
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High flow closed circuit anaesthesia.
    Verkaaik AP; Van Dijk G
    Anaesth Intensive Care; 1994 Aug; 22(4):426-34. PubMed ID: 7978208
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Elevated inspiratory CO2 concentrations caused by the design of an anesthesia machine.
    Sperl K; Jöhr M
    Acta Anaesthesiol Scand; 2003 Apr; 47(4):496. PubMed ID: 12694161
    [No Abstract]   [Full Text] [Related]  

  • 18. An unusual anesthesia machine leak.
    Mark D
    J Clin Anesth; 2000 Feb; 12(1):87. PubMed ID: 10785878
    [No Abstract]   [Full Text] [Related]  

  • 19. Cardiogenic oscillations may be masked by the breathing system configuration.
    Haridas RP; Murray WB; Bhimsan NR
    J Clin Monit; 1997 Jul; 13(4):269-72. PubMed ID: 9269621
    [No Abstract]   [Full Text] [Related]  

  • 20. Back to basics--a simplified non-mathematical approach to low flow techniques in anaesthesia.
    Baker AB
    Anaesth Intensive Care; 1994 Aug; 22(4):394-5. PubMed ID: 7978203
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 7.