BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 8696888)

  • 1. Hydrostatic systolic toe pressure for diagnosis of peripheral ischaemic vessel disease in diabetes mellitus.
    Chantelau E; Sambraus HW
    Eur J Vasc Endovasc Surg; 1996 Jul; 12(1):125-6. PubMed ID: 8696888
    [No Abstract]   [Full Text] [Related]  

  • 2. Hydrostatic toe-pressure measurement for assessment of limb ischaemia.
    Chantelau E; Sambraus HW
    Lancet; 1995 Sep; 346(8978):854. PubMed ID: 7674791
    [No Abstract]   [Full Text] [Related]  

  • 3. Bioelectrical impedance sphygmography for hydrostatic toe pressure measurement: a new non-invasive method to assess limb ischaemia.
    Beyenal-Ogmen B
    Vasa; 1999 Feb; 28(1):15-8. PubMed ID: 10191701
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Skin perfusion pressure of the foot is a good substitute for toe pressure in the assessment of limb ischemia.
    Tsai FW; Tulsyan N; Jones DN; Abdel-Al N; Castronuovo JJ; Carter SA
    J Vasc Surg; 2000 Jul; 32(1):32-6. PubMed ID: 10876204
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Functional diagnosis of peripheral artery diseases].
    Kubota Y
    Nihon Naika Gakkai Zasshi; 2008 Feb; 97(2):309-16. PubMed ID: 18404843
    [No Abstract]   [Full Text] [Related]  

  • 6. The definition of critical ischemia of the lower limb and distal systolic pressures.
    Carter SA
    Br J Surg; 1983 Mar; 70(3):188-9. PubMed ID: 6831167
    [No Abstract]   [Full Text] [Related]  

  • 7. Value of toe pulse waves in addition to systolic pressures in the assessment of the severity of peripheral arterial disease and critical limb ischemia.
    Carter SA; Tate RB
    J Vasc Surg; 1996 Aug; 24(2):258-65. PubMed ID: 8752037
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A prospective comparison of bilateral photoplethysmography versus the ankle-brachial pressure index for detecting and quantifying lower limb peripheral arterial disease.
    Allen J; Overbeck K; Nath AF; Murray A; Stansby G
    J Vasc Surg; 2008 Apr; 47(4):794-802. PubMed ID: 18381141
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The validity and reliability of automated and manually measured toe blood pressure in ischemic legs of diabetic patients.
    Påhlsson HI; Lund K; Jörneskog G; Gush R; Wahlberg E
    Eur J Vasc Endovasc Surg; 2008 Nov; 36(5):576-81. PubMed ID: 18801666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Indirect measurement of systolic blood pressure in the lower limb using a mercury in rubber strain gauge.
    Bell G; Nielsen PE; Lassen NA; Wolfson B
    Cardiovasc Res; 1973 Mar; 7(2):282-9. PubMed ID: 4694112
    [No Abstract]   [Full Text] [Related]  

  • 11. The hydrostatic measurement of systolic toe blood pressure: a preliminary validation of the method.
    Hiller B
    Vasa; 1998 Nov; 27(4):229-32. PubMed ID: 9859743
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Hydrostatic toe pressure measurement: a noninvasive screening method in the diagnosis of arterial occlusive diseases in diabetics and nondiabetics].
    Sambraus HW
    Dtsch Med Wochenschr; 1996 Mar; 121(12):364-8. PubMed ID: 8815014
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Painful black toe - a case study.
    Leung L
    Aust Fam Physician; 2012 Sep; 41(9):704-6. PubMed ID: 22962648
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measurement of blood pressure in all toes in arterial occlusive disease of the leg.
    Hirai M; Kawai S; Ohta T; Seko T; Shionoya S
    Angiology; 1982 Jun; 33(6):418-26. PubMed ID: 7091772
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Toe pressure measurements compared to ankle artery pressure measurements.
    Kröger K; Stewen C; Santosa F; Rudofsky G
    Angiology; 2003 Jan; 54(1):39-44. PubMed ID: 12593494
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The ischaemic leg: a long-term follow-up with special reference to the predictive value of the systolic digital blood pressure. Part II: After arterial reconstruction.
    Nielsen PH; Andersen HJ; Bille S; Holstein P; Egeblad K
    Thorac Cardiovasc Surg; 1989 Dec; 37(6):351-4. PubMed ID: 2617500
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new automated toe blood pressure monitor for assessment of limb ischemia.
    Wahlberg E; Gush R
    Eur J Vasc Endovasc Surg; 2002 Oct; 24(4):304-8. PubMed ID: 12323172
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive vascular laboratory for evaluation of peripheral arterial occlusive disease: Part II--clinical applications: chronic, usually atherosclerotic, lower extremity ischemia.
    Rose SC
    J Vasc Interv Radiol; 2000; 11(10):1257-75. PubMed ID: 11099236
    [No Abstract]   [Full Text] [Related]  

  • 19. Second Toe Systolic Pressure Measurements are Valid Substitutes for First Toe Systolic Pressure Measurements in Diabetic Patients: A Prospective Study.
    Bhamidipaty V; Dean A; Yap SL; Firth J; Barron M; Allard B; Chan ST
    Eur J Vasc Endovasc Surg; 2015 Jan; 49(1):77-82. PubMed ID: 25453237
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Digital blood pressure in normal subjects and patients with peripheral arterial disease.
    Nielsen PE
    Scand J Clin Lab Invest; 1976 Dec; 36(8):725-30. PubMed ID: 1031484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.