BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 870610)

  • 21. [A new enzymatic determination of cholesterol and comparison of various cholesterol oxidases (author's transl)].
    Nakayama K; Okabe H; Noma A
    Rinsho Byori; 1976; 24(11):921-5. PubMed ID: 1034784
    [No Abstract]   [Full Text] [Related]  

  • 22. Amperometric determination of total cholesterol in serum, with use of immobilized cholesterol ester hydrolase and cholesterol oxidase.
    Huang HS; Kuan SS; Guilbault GG
    Clin Chem; 1977; 23(4):671-6. PubMed ID: 14793
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Effects of the activators on enzymatic determination of total serum cholesterol (author's transl)].
    Kasahara Y; Sugiyama M; Saito Y; Yamada N
    Rinsho Byori; 1979; 27(1):51-6. PubMed ID: 430875
    [No Abstract]   [Full Text] [Related]  

  • 24. Enzymatic rate method for measuring cholesterol in serum.
    Pesce MA; Bodourian SH
    Clin Chem; 1976 Dec; 22(12):2042-5. PubMed ID: 11901
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Enzymic assay of plasma cholesterol: a comparison of analytical variations found using the Greiner GSA II and the Technicon SMA 12/60 and SMA II.
    Steinmetz J; Panek E; Gaspart E
    J Clin Chem Clin Biochem; 1979 Aug; 17(8):547-51. PubMed ID: 501301
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Multicentre study of a new enzymatic method of cholesterol determination.
    Kattermann R; Jaworek D; Möller G; Assmann G; Björkhem I; Svensson L; Borner K; Boerma G; Leijnse B; Desager JP
    J Clin Chem Clin Biochem; 1984 Mar; 22(3):245-51. PubMed ID: 6327876
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Enzymatic methods for quantitative determination of total cholesterol in blood serum].
    Pedchenko VV; Malakhov VN
    Vopr Med Khim; 1991; 37(4):85-91. PubMed ID: 1750219
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Studies on determination of cholesterol using enzyme method (author's transl)].
    Maeda H; Nakamura N; Uzawa H
    Rinsho Byori; 1976 Feb; 24(2):159-61. PubMed ID: 944317
    [No Abstract]   [Full Text] [Related]  

  • 29. [The determination of bilirubin as azobilirubin in plasma and serum with the Greiner electronic selective analyzer GSA II (author's transl)].
    Küffer H; Richterich R; Peheim E; Colombo JP
    Z Klin Chem Klin Biochem; 1974 Jun; 12(6):294-302. PubMed ID: 4428842
    [No Abstract]   [Full Text] [Related]  

  • 30. [Emerson-Trinder reaction: study of various chromogens and analyses of the principle interferences (author's transl)].
    Fossati P; Prencipe L
    Quad Sclavo Diagn; 1978 Jun; 14(2):164-77. PubMed ID: 751094
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Enzymatic determination of total cholesterol in serum: accuracy and comparison with other methods (author's transl)].
    Stähler F; Munz E; Kattermann R
    Dtsch Med Wochenschr; 1975 Apr; 100(16):876-80, 885-7. PubMed ID: 1122846
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Estimation of serum lipids: method without extraction adapted to autoanalysis (author's transl)].
    Tallet F; Raichvarg D; Didry JR; Caillens H
    Ann Biol Clin (Paris); 1979; 37(6):355-60. PubMed ID: 547761
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [The determination of glucose in plasma and serum (hexokinase-glucose-6-phosphate dehydrogenase method) with the Greiner electronic selective analyzer GSA II (author's transl)].
    Richterich R; Küffer H; Lorenz E; Colombo JP
    Z Klin Chem Klin Biochem; 1974 Jan; 12(1):5-13. PubMed ID: 4819716
    [No Abstract]   [Full Text] [Related]  

  • 34. Microenzymatic fluorescence assay for serum cholesterol.
    Gray MC; Plant AL; Nicholson JM; May WE
    Anal Biochem; 1995 Jan; 224(1):286-92. PubMed ID: 7710084
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Letter: Enzymatic determination of total serum cholesterol with the Vickers D-300 analyzer.
    Zoppi F; Fenili D
    Clin Chem; 1976 May; 22(5):690-1. PubMed ID: 1261022
    [No Abstract]   [Full Text] [Related]  

  • 36. Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.
    Cherian AG; Soldin SJ; Hill JG
    Clin Chem; 1981 May; 27(5):748-52. PubMed ID: 7226499
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Kinetic enzymatic method for automated determination of glucose in blood and serum.
    Ziegenhorn J; Neumann U; Hagen A; Bablok W; Strinshoff K
    J Clin Chem Clin Biochem; 1977 Jan; 15(1):13-9. PubMed ID: 839160
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Multicentre evaluation of the Boehringer Mannheim/Hitachi 747 analysis system.
    Bonini P; Ceriotti F; Keller F; Brauer P; Stolz H; Pascual C; García Beltrán L; Vonderschmitt DJ; Pei P
    Eur J Clin Chem Clin Biochem; 1992 Dec; 30(12):881-99. PubMed ID: 1489865
    [TBL] [Abstract][Full Text] [Related]  

  • 39. [Enzymatic estimation of cholesterol (author's transl)].
    Homolka J
    Cas Lek Cesk; 1977 Nov; 116(45):1387-9. PubMed ID: 603884
    [No Abstract]   [Full Text] [Related]  

  • 40. Automated measurement of total cholesterol and triglycerides, in "tandem," on the discrete sample analyzer, Gilford System 3500.
    Smith L; Lucas D; Lehnus G
    Clin Chem; 1979 Mar; 25(3):439-42. PubMed ID: 262187
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.