These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 8707787)

  • 1. A three-dimensional, time-dependent analysis of flow through a bileaflet mechanical heart valve: comparison of experimental and numerical results.
    King MJ; Corden J; David T; Fisher J
    J Biomech; 1996 May; 29(5):609-18. PubMed ID: 8707787
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical analysis of the hemodynamic performance of bileaflet mechanical heart valves at different implantation angles.
    Kuan YH; Nguyen VT; Kabinejadian F; Su B; Kim S; Yoganathan AP; Leo HL
    J Heart Valve Dis; 2014 Sep; 23(5):642-50. PubMed ID: 25799715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve.
    King MJ; David T; Fisher J
    Med Eng Phys; 1997 Apr; 19(3):235-41. PubMed ID: 9239642
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Three-dimensional numeric simulation of flow through an aortic bileaflet valve in a realistic model of aortic root.
    Grigioni M; Daniele C; Del Gaudio C; Morbiducci U; Balducci A; D'Avenio G; Barbaro V
    ASAIO J; 2005; 51(3):176-83. PubMed ID: 15968945
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of hinge microflow fields of bileaflet mechanical heart valves implanted in different sinus shape and downstream geometry.
    Kuan YH; Kabinejadian F; Nguyen VT; Su B; Yoganathan AP; Leo HL
    Comput Methods Biomech Biomed Engin; 2015; 18(16):1785-96. PubMed ID: 25343223
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dynamic particle image velocimetry study of the aortic flow field of contemporary mechanical bileaflet prostheses.
    Akutsu T; Saito J; Imai R; Suzuki T; Cao XD
    J Artif Organs; 2008; 11(2):75-90. PubMed ID: 18604612
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation technique for bileaflet mechanical valves.
    Shipkowitz T; Ambrus J; Kurk J; Wickramasinghe K
    J Heart Valve Dis; 2002 Mar; 11(2):275-82. PubMed ID: 12000172
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An in vitro comparative study of St. Jude Medical and Edwards-Duromedics bileaflet valves using laser anemometry.
    Fatemi R; Chandran KB
    J Biomech Eng; 1989 Nov; 111(4):298-302. PubMed ID: 2486368
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fluid-structure interaction of deformable aortic prostheses with a bileaflet mechanical valve.
    de Tullio MD; Afferrante L; Demelio G; Pascazio G; Verzicco R
    J Biomech; 2011 Jun; 44(9):1684-90. PubMed ID: 21496823
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.
    Ellis JT; Healy TM; Fontaine AA; Weston MW; Jarret CA; Saxena R; Yoganathan AP
    J Heart Valve Dis; 1996 Nov; 5(6):600-6. PubMed ID: 8953437
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of the sinus of valsalva on the closing motion of bileaflet prosthetic heart valves.
    Ohta Y; Kikuta Y; Shimooka T; Mitamura Y; Yuhta T; Dohi T
    Artif Organs; 2000 Apr; 24(4):309-12. PubMed ID: 10816206
    [TBL] [Abstract][Full Text] [Related]  

  • 12. CFD simulation of a novel bileaflet mechanical heart valve prosthesis: an estimation of the Venturi passage formed by the leaflets.
    Yokoyama Y; Medart D; Hormes M; Schmitz C; Hamilton K; Kwant PB; Takatani S; Schmitz-Rode T; Steinseifer U
    Int J Artif Organs; 2006 Dec; 29(12):1132-9. PubMed ID: 17219353
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hydrodynamic evaluation of three artificial aortic valve chambers.
    Morsi YS; Sakhaeimanesh A; Clayton BR
    Artif Organs; 2000 Jan; 24(1):57-63. PubMed ID: 10677158
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Computational Hemodynamic Investigation of Bileaflet and Trileaflet Mechanical Heart Valves.
    Kuan YH; Nguyen VT; Kabinejadian F; Leo HL
    J Heart Valve Dis; 2015 May; 24(3):393-403. PubMed ID: 26901919
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow in a mechanical bileaflet heart valve at laminar and near-peak systole flow rates: CFD simulations and experiments.
    Ge L; Leo HL; Sotiropoulos F; Yoganathan AP
    J Biomech Eng; 2005 Oct; 127(5):782-97. PubMed ID: 16248308
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computational fluid dynamics insights in the design of mechanical heart valves.
    Kelly SG
    Artif Organs; 2002 Jul; 26(7):608-13. PubMed ID: 12081519
    [TBL] [Abstract][Full Text] [Related]  

  • 17. In vitro fluid dynamic evaluation of the Carbomedics bileaflet heart valve prosthesis in the aortic and mitral positions.
    Sung HW; Cape EG; Yoganathan AP
    J Heart Valve Dis; 1994 Nov; 3(6):673-83. PubMed ID: 8000612
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow.
    Subramanian A; Mu H; Kadambi JR; Wernet MP; Brendzel AM; Harasaki H
    J Heart Valve Dis; 2000 Sep; 9(5):721-31. PubMed ID: 11041190
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve design.
    Leo HL; He Z; Ellis JT; Yoganathan AP
    J Thorac Cardiovasc Surg; 2002 Sep; 124(3):561-74. PubMed ID: 12202873
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Numerical simulation of opening process in a bileaflet mechanical heart valve under pulsatile flow condition.
    Shi Y; Zhao Y; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Mar; 12(2):245-55. PubMed ID: 12701798
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.