188 related articles for article (PubMed ID: 8718946)
21. Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis.
Zhang M; Turner-Smith AR; Tanner A; Roberts VC
Med Eng Phys; 1998 Apr; 20(3):188-98. PubMed ID: 9690489
[TBL] [Abstract][Full Text] [Related]
22. A comparison of pressure distributions between two types of sockets in a bulbous stump.
Gholizadeh H; Abu Osman NA; Eshraghi A; Arifin N; Chung TY
Prosthet Orthot Int; 2016 Aug; 40(4):509-16. PubMed ID: 25583929
[TBL] [Abstract][Full Text] [Related]
23. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.
Portnoy S; Yarnitzky G; Yizhar Z; Kristal A; Oppenheim U; Siev-Ner I; Gefen A
Ann Biomed Eng; 2007 Jan; 35(1):120-35. PubMed ID: 17120139
[TBL] [Abstract][Full Text] [Related]
24. Interface Pressure System to Compare the Functional Performance of Prosthetic Sockets during the Gait in People with Trans-Tibial Amputation.
Ibarra Aguila S; Sánchez GJ; Sauvain EE; Alemon B; Fuentes-Aguilar RQ; Huegel JC
Sensors (Basel); 2020 Dec; 20(24):. PubMed ID: 33317006
[TBL] [Abstract][Full Text] [Related]
25. Interface load analysis for computer-aided design of below-knee prosthetic sockets.
Reynolds DP; Lord M
Med Biol Eng Comput; 1992 Jul; 30(4):419-26. PubMed ID: 1487943
[TBL] [Abstract][Full Text] [Related]
26. [Inertial effects on interface pressure between prosthetic socket and residual limb].
Jia X; Zhang M; Wang R; Fan Y
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Jun; 22(3):468-71. PubMed ID: 16013238
[TBL] [Abstract][Full Text] [Related]
27. Interface pressures and shear stresses at thirteen socket sites on two persons with transtibial amputation.
Sanders JE; Lam D; Dralle AJ; Okumura R
J Rehabil Res Dev; 1997 Jan; 34(1):19-43. PubMed ID: 9021623
[TBL] [Abstract][Full Text] [Related]
28. Generic, geometric finite element analysis of the transtibial residual limb and prosthetic socket.
Silver-Thorn MB; Childress DS
J Rehabil Res Dev; 1997 Apr; 34(2):171-86. PubMed ID: 9108344
[TBL] [Abstract][Full Text] [Related]
29. Normal and shear stresses on a residual limb in a prosthetic socket during ambulation: comparison of finite element results with experimental measurements.
Sanders JE; Daly CH
J Rehabil Res Dev; 1993; 30(2):191-204. PubMed ID: 8035348
[TBL] [Abstract][Full Text] [Related]
30. Finite element estimates of interface stress in the trans-tibial prosthesis using gap elements are different from those using automated contact.
Zachariah SG; Sanders JE
J Biomech; 2000 Jul; 33(7):895-9. PubMed ID: 10831765
[TBL] [Abstract][Full Text] [Related]
31. Techniques for Interface Stress Measurements within Prosthetic Sockets of Transtibial Amputees: A Review of the Past 50 Years of Research.
Al-Fakih EA; Abu Osman NA; Mahmad Adikan FR
Sensors (Basel); 2016 Jul; 16(7):. PubMed ID: 27447646
[TBL] [Abstract][Full Text] [Related]
32. Finite element analysis of donning procedure of a prosthetic transfemoral socket.
Lacroix D; Patiño JF
Ann Biomed Eng; 2011 Dec; 39(12):2972-83. PubMed ID: 21887588
[TBL] [Abstract][Full Text] [Related]
33. Interface mechanics in external prosthetics: review of interface stress measurement techniques.
Sanders JE
Med Biol Eng Comput; 1995 Jul; 33(4):509-16. PubMed ID: 7475380
[TBL] [Abstract][Full Text] [Related]
34. Method for the design and analysis of a non-linear anisotropic lower limb prosthetic socket.
Soh AK; Soh CK; Lau WS
J Biomed Eng; 1990 Nov; 12(6):470-6. PubMed ID: 2266742
[TBL] [Abstract][Full Text] [Related]
35. COMBINED EFFECT OF THERMAL LOAD AND MECHANICAL LOAD IN TRANSTIBIAL PROSTHESIS. AN EMPIRICAL STUDY.
Filep R; Ilea M; Turnea M; Arotăriţei D; Rotariu M; Popescu M
Rev Med Chir Soc Med Nat Iasi; 2016; 120(1):186-91. PubMed ID: 27125094
[TBL] [Abstract][Full Text] [Related]
36. Stump-socket interface pressure as an aid to socket design in prostheses for trans-femoral amputees--a preliminary study.
Lee VS; Solomonidis SE; Spence WD
Proc Inst Mech Eng H; 1997; 211(2):167-80. PubMed ID: 9184457
[TBL] [Abstract][Full Text] [Related]
37. Effects of liner stiffness for trans-tibial prosthesis: a finite element contact model.
Lin CC; Chang CH; Wu CL; Chung KC; Liao IC
Med Eng Phys; 2004 Jan; 26(1):1-9. PubMed ID: 14644593
[TBL] [Abstract][Full Text] [Related]
38. Measurement of biomechanical interactions at the stump-socket interface in lower limb prostheses.
Noll V; Wojtusch J; Schuy J; Grimmer M; Beckerle P; Rinderknecht S
Annu Int Conf IEEE Eng Med Biol Soc; 2015 Aug; 2015():5517-20. PubMed ID: 26737541
[TBL] [Abstract][Full Text] [Related]
39. Study on friction behavior at the interface between prosthetic socket and liner.
Xie J; Liu X; Tang J; Li XI; Li W
Acta Bioeng Biomech; 2021; 23(1):83-93. PubMed ID: 34846045
[TBL] [Abstract][Full Text] [Related]
40. Key considerations for finite element modelling of the residuum-prosthetic socket interface.
Steer JW; Worsley PR; Browne M; Dickinson A
Prosthet Orthot Int; 2021 Apr; 45(2):138-146. PubMed ID: 33176573
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]