These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

80 related articles for article (PubMed ID: 8721704)

  • 1. Maintenance of coronary guidewire position during guide catheter exchange.
    Azrin MA; Fram DB; Hirst JA; Mitchel JF; Mckay RG
    Cathet Cardiovasc Diagn; 1996 Apr; 37(4):453-4. PubMed ID: 8721704
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Successful crossing of an angulated lesion using a new deflectable-tip guidewire (Steer-IT).
    Barlis P; Tanigawa J; Di Mario C
    J Invasive Cardiol; 2007 Jun; 19(6):E154-5. PubMed ID: 17541136
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Percutaneous retrieval of transsected rotablator coronary guidewire using Amplatz "Goose-Neck snare".
    Pande AK; Doucet S
    Indian Heart J; 1998; 50(4):439-42. PubMed ID: 9835207
    [No Abstract]   [Full Text] [Related]  

  • 4. The steerable guidewire: a simple method to recross deployed stents.
    Chen JP
    J Invasive Cardiol; 2006 Nov; 18(11):575. PubMed ID: 17090826
    [No Abstract]   [Full Text] [Related]  

  • 5. [Coaxial catheterization with an ultra-flexible catheter (Tracker) in coronary angioplasty].
    Brenot P; Riou JY; Angel CY; Leriche H
    Arch Mal Coeur Vaiss; 1990 Jun; 83(7):983-8. PubMed ID: 2114859
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The use of the Tracker catheter as a guidewire support device in angioplasty of angulated and tortuous circumflex coronary arteries.
    Pimentel CX; Schreiter SW; Gurbel PA
    J Invasive Cardiol; 1995 Apr; 7(3):66-71. PubMed ID: 10155365
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Percutaneous transluminal coronary angioplasty hardware entrapment: guidewire entrapment.
    Capuano F; Simon C; Roscitano A; Sinatra R
    J Cardiovasc Med (Hagerstown); 2008 Nov; 9(11):1140-1. PubMed ID: 18852589
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Comment on K. Kröger, G. Görge, R. Erbel and G. Rudolfsky, "Radial artery as approach to diagnostic coronary angiography"].
    Kindel M
    Z Kardiol; 1997 Oct; 86(10):877-8. PubMed ID: 9454456
    [No Abstract]   [Full Text] [Related]  

  • 9. Extreme coronary guide catheter support: a case of a novel telescopic guide catheter system with a contralateral aortic wall support.
    Stys AT; Lawson W; Brown D
    J Invasive Cardiol; 2007 Apr; 19(4):E107-10. PubMed ID: 17404415
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The Ultra-Select guidewire: a new nitinol guidewire for coronary angioplasty.
    Mooney MR; Mooney JF; Pedersen WR; Goldenberg IF; Gobel FL
    J Invasive Cardiol; 1991; 3(5):242-5. PubMed ID: 10149107
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Successful use of the frontrunner catheter in the treatment of in-stent coronary chronic total occlusions.
    Yang YM; Mehran R; Dangas G; Reyes A; Qin J; Stone GW; Leon MB; Moses JW
    Catheter Cardiovasc Interv; 2004 Dec; 63(4):462-8. PubMed ID: 15558776
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Total occlusion: old vs. new technology.
    Turi ZG
    Catheter Cardiovasc Interv; 2003 Jun; 59(2):259-60. PubMed ID: 12772254
    [No Abstract]   [Full Text] [Related]  

  • 13. Effects of diagnostic guidewire catheter presence on translesional hemodynamic measurements across significant coronary artery stenoses.
    Banerjee RK; Back LH; Back MR
    Biorheology; 2003; 40(6):613-35. PubMed ID: 14610312
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Initial characterization of Ikari Guide catheter for transradial coronary intervention.
    Ikari Y; Nakajima H; Iijima R; Aoki J; Tanabe K; Nakayama T; Miyazawa A; Hatori M; Kyouno H; Tanimoto S; Amiya E; Nakazawa G; Onuma Y; Hara K
    J Invasive Cardiol; 2004 Feb; 16(2):65-8. PubMed ID: 14760193
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [De-novo reversible stenoses in tortuous arteries during coronary angioplasty due to the accordion effect. A clinical case and review of the literature].
    Gouveia D; Escudero J; Domingo E; Anivarro I; Angel J; Soler JS
    Rev Port Cardiol; 1997 Dec; 16(12):1037-42, 957. PubMed ID: 9522627
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Primer on consensus in guide selection for performance of transradial coronary angioplasty.
    Hilton D
    J Indian Med Assoc; 2009 Sep; 107(9):595-6. PubMed ID: 20337235
    [No Abstract]   [Full Text] [Related]  

  • 17. Straightening a kinked guidewire extension.
    Koh TH
    Cathet Cardiovasc Diagn; 1996 Nov; 39(3):300-1. PubMed ID: 8933978
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Enhanced manipulation of directional coronary atherectomy and coronary angioplasty guide catheters.
    Ormiston JA; Ng K; Webster MW
    Cathet Cardiovasc Diagn; 1996 Apr; 37(4):425-7. PubMed ID: 8721698
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The fracture, dislodgement and retrieval of a probe III balloon-on-a-wire catheter.
    Hwang MH; Hsieh AA; Silverman P; Loeb HS
    J Invasive Cardiol; 1994 Jun; 6(5):154-6. PubMed ID: 10155063
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [1st heart catheter, 1st coronary dilatation, 1st resorbable stent. Renewed breakthroughs in German research].
    MMW Fortschr Med; 2005 Apr; 147(15):16. PubMed ID: 15884497
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 4.