These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

226 related articles for article (PubMed ID: 8722819)

  • 1. Removal of lipid artifacts in 1H spectroscopic imaging by data extrapolation.
    Haupt CI; Schuff N; Weiner MW; Maudsley AA
    Magn Reson Med; 1996 May; 35(5):678-87. PubMed ID: 8722819
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of methods for reduction of lipid contamination for in vivo proton MR spectroscopic imaging of the brain.
    Ebel A; Maudsley AA
    Magn Reson Med; 2001 Oct; 46(4):706-12. PubMed ID: 11590647
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Reduction of lipid contamination in MR spectroscopy imaging using signal space projection.
    Tsai SY; Lin YR; Lin HY; Lin FH
    Magn Reson Med; 2019 Mar; 81(3):1486-1498. PubMed ID: 30277271
    [TBL] [Abstract][Full Text] [Related]  

  • 4. MRS imaging using anatomically based k-space sampling and extrapolation.
    Plevritis SK; Macovski A
    Magn Reson Med; 1995 Nov; 34(5):686-93. PubMed ID: 8544688
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reduced phase encoding in spectroscopic imaging.
    Maudsley AA; Matson GB; Hugg JW; Weiner MW
    Magn Reson Med; 1994 Jun; 31(6):645-51. PubMed ID: 8057817
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Compartmentalized low-rank recovery for high-resolution lipid unsuppressed MRSI.
    Bhattacharya I; Jacob M
    Magn Reson Med; 2017 Oct; 78(4):1267-1280. PubMed ID: 27851875
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Three-dimensional MR spectroscopic imaging using adiabatic spin echo and hypergeometric dual-band suppression for metabolic mapping over the entire brain.
    Esmaeili M; Bathen TF; Rosen BR; Andronesi OC
    Magn Reson Med; 2017 Feb; 77(2):490-497. PubMed ID: 26840906
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Lipid suppression via double inversion recovery with symmetric frequency sweep for robust 2D-GRAPPA-accelerated MRSI of the brain at 7 T.
    Hangel G; Strasser B; Považan M; Gruber S; Chmelík M; Gajdošík M; Trattnig S; Bogner W
    NMR Biomed; 2015 Nov; 28(11):1413-25. PubMed ID: 26370781
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High-resolution (1) H-MRSI of the brain using SPICE: Data acquisition and image reconstruction.
    Lam F; Ma C; Clifford B; Johnson CL; Liang ZP
    Magn Reson Med; 2016 Oct; 76(4):1059-70. PubMed ID: 26509928
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Narrow band deformable registration of prostate magnetic resonance imaging, magnetic resonance spectroscopic imaging, and computed tomography studies.
    Schreibmann E; Xing L
    Int J Radiat Oncol Biol Phys; 2005 Jun; 62(2):595-605. PubMed ID: 15890605
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Truncation artifact reduction in spectroscopic imaging using a dual-density spiral k-space trajectory.
    Sarkar S; Heberlein K; Hu X
    Magn Reson Imaging; 2002 Dec; 20(10):743-57. PubMed ID: 12591570
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Investigation of the PSF-choice method for reduced lipid contamination in prostate MR spectroscopic imaging.
    Panych LP; Roebuck JR; Chen NK; Tang Y; Madore B; Tempany CM; Mulkern RV
    Magn Reson Med; 2012 Nov; 68(5):1376-82. PubMed ID: 22648701
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of inversion recovery preparation schemes for lipid suppression in 1H MRSI of human brain.
    Ebel A; Govindaraju V; Maudsley AA
    Magn Reson Med; 2003 May; 49(5):903-8. PubMed ID: 12704773
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Improved reconstruction for MR spectroscopic imaging.
    Bao Y; Maudsley AA
    IEEE Trans Med Imaging; 2007 May; 26(5):686-95. PubMed ID: 17518063
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultrafast magnetic resonance spectroscopic imaging using SPICE with learned subspaces.
    Lam F; Li Y; Guo R; Clifford B; Liang ZP
    Magn Reson Med; 2020 Feb; 83(2):377-390. PubMed ID: 31483526
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Method for fast lipid reconstruction and removal processing in
    Adany P; Choi IY; Lee P
    Magn Reson Med; 2021 Dec; 86(6):2930-2944. PubMed ID: 34337788
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Lipid suppression in CSI with spatial priors and highly undersampled peripheral k-space.
    Bilgic B; Gagoski B; Kok T; Adalsteinsson E
    Magn Reson Med; 2013 Jun; 69(6):1501-11. PubMed ID: 22807147
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reduced lipid contamination in in vivo 1H MRSI using time-domain fitting and neural network classification.
    de Beer R; Michels F; van Ormondt D; van Tongeren BP; Luyten PR; van Vroonhoven H
    Magn Reson Imaging; 1993; 11(7):1019-26. PubMed ID: 8231665
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Retrospective motion compensation for edited MR spectroscopic imaging.
    Chan KL; Barker PB
    Neuroimage; 2019 Nov; 202():116141. PubMed ID: 31479753
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Removal of nuisance signals from limited and sparse 1H MRSI data using a union-of-subspaces model.
    Ma C; Lam F; Johnson CL; Liang ZP
    Magn Reson Med; 2016 Feb; 75(2):488-97. PubMed ID: 25762370
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.