170 related articles for article (PubMed ID: 8725411)
1. The agreement between ventricular volumes and ejection fraction by transesophageal echocardiography or a combined radionuclear and thermodilution technique in patients after coronary artery surgery.
Ryan T; Burwash I; Lu J; Otto C; Graham M; Verrier E; Spiess BD
J Cardiothorac Vasc Anesth; 1996 Apr; 10(3):323-8. PubMed ID: 8725411
[TBL] [Abstract][Full Text] [Related]
2. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.
Graeser K; Zemtsovski M; Kofoed KF; Winther-Jensen M; Nilsson JC; Kjaergaard J; Møller-Sørensen H
Anesth Analg; 2018 Aug; 127(2):399-407. PubMed ID: 29324489
[TBL] [Abstract][Full Text] [Related]
3. Quantification of left ventricular ejection fraction and cardiac output using a novel semi-automated echocardiographic method: a prospective observational study in coronary artery bypass patients.
Komanek T; Rabis M; Omer S; Peters J; Frey UH
BMC Anesthesiol; 2023 Feb; 23(1):65. PubMed ID: 36855077
[TBL] [Abstract][Full Text] [Related]
4. The discrepancy between echocardiography, cineventriculography and thermodilution. Evaluation of left ventricular volume and ejection fraction.
Takenaka A; Iwase M; Sobue T; Yokota M
Int J Card Imaging; 1995 Dec; 11(4):255-62. PubMed ID: 8596064
[TBL] [Abstract][Full Text] [Related]
5. Intraoperative three-dimensional versus two-dimensional echocardiography for left ventricular assessment.
Meris A; Santambrogio L; Casso G; Mauri R; Engeler A; Cassina T
Anesth Analg; 2014 Apr; 118(4):711-20. PubMed ID: 24651224
[TBL] [Abstract][Full Text] [Related]
6. Quantitation of right ventricular volumes and ejection fraction by three-dimensional echocardiography in patients: comparison with magnetic resonance imaging and radionuclide ventriculography.
Nesser HJ; Tkalec W; Patel AR; Masani ND; Niel J; Markt B; Pandian NG
Echocardiography; 2006 Sep; 23(8):666-80. PubMed ID: 16970718
[TBL] [Abstract][Full Text] [Related]
7. Transesophageal echocardiographic area and Doppler flow velocity measurements: comparison with hemodynamic changes in coronary artery bypass surgery.
Schmidlin D; Jenni R; Schmid ER
J Cardiothorac Vasc Anesth; 1999 Apr; 13(2):143-9. PubMed ID: 10230946
[TBL] [Abstract][Full Text] [Related]
8. Left ventricular ejection fraction: single-plane and multiplanar transesophageal echocardiography versus equilibrium gated-pool scintigraphy.
Nessly ML; Bashein G; Detmer PR; Graham MM; Kao R; Martin RW
J Cardiothorac Vasc Anesth; 1991 Feb; 5(1):40-5. PubMed ID: 1868183
[TBL] [Abstract][Full Text] [Related]
9. Clinical estimation of left and right ventricular volume with open chest compared with transesophageal echocardiography and fast-response thermodilution.
Samuelsson S; Ehrenberg J; Settergren G
J Cardiothorac Vasc Anesth; 1995 Dec; 9(6):670-5. PubMed ID: 8664458
[TBL] [Abstract][Full Text] [Related]
10. Comparison between radionuclide ejection fraction and fractional area changes derived from transesophageal echocardiography using automated border detection.
Liu N; Darmon PL; Saada M; Catoire P; Rosso J; Berger G; Bonnet F
Anesthesiology; 1996 Sep; 85(3):468-74. PubMed ID: 8853075
[TBL] [Abstract][Full Text] [Related]
11. Comparison of Cardiac Output of Both 2-Dimensional and 3-Dimensional Transesophageal Echocardiography With Transpulmonary Thermodilution During Cardiac Surgery.
Canty DJ; Kim M; Guha R; Pham T; Royse AG; Errey-Clarke S; Smith JA; Royse CF
J Cardiothorac Vasc Anesth; 2020 Jan; 34(1):77-86. PubMed ID: 31375406
[TBL] [Abstract][Full Text] [Related]
12. Three-dimensional echocardiographic determination of left ventricular volumes and function by multiplane transesophageal transducer: dynamic in vitro validation and in vivo comparison with angiography and thermodilution.
Kühl HP; Franke A; Janssens U; Merx M; Graf J; Krebs W; Reul H; Rau G; Hoffmann R; Klues HG; Hanrath P
J Am Soc Echocardiogr; 1998 Dec; 11(12):1113-24. PubMed ID: 9923991
[TBL] [Abstract][Full Text] [Related]
13. Comparison of left ventricular ejection fraction and volumes in heart failure by echocardiography, radionuclide ventriculography and cardiovascular magnetic resonance; are they interchangeable?
Bellenger NG; Burgess MI; Ray SG; Lahiri A; Coats AJ; Cleland JG; Pennell DJ
Eur Heart J; 2000 Aug; 21(16):1387-96. PubMed ID: 10952828
[TBL] [Abstract][Full Text] [Related]
14. Value and limitations of transesophageal echocardiography in determination of left ventricular volumes and ejection fraction.
Smith MD; MacPhail B; Harrison MR; Lenhoff SJ; DeMaria AN
J Am Coll Cardiol; 1992 May; 19(6):1213-22. PubMed ID: 1564222
[TBL] [Abstract][Full Text] [Related]
15. Comparison of different echocardiographic methods with radionuclide imaging for measuring left ventricular ejection fraction during acute myocardial infarction treated by thrombolytic therapy.
Jensen-Urstad K; Bouvier F; Höjer J; Ruiz H; Hulting J; Samad B; Thorstrand C; Jensen-Urstad M
Am J Cardiol; 1998 Mar; 81(5):538-44. PubMed ID: 9514446
[TBL] [Abstract][Full Text] [Related]
16. Determination of right ventricular function by transesophageal echocardiography: impact of proximal right coronary artery stenosis.
Niimi Y; Hiki M; Ishiguro Y; Goto T; Morita S
J Clin Anesth; 2004 Mar; 16(2):104-10. PubMed ID: 15110371
[TBL] [Abstract][Full Text] [Related]
17. Comparison of transesophageal echocardiographic and scintigraphic estimates of left ventricular end-diastolic volume index and ejection fraction in patients following coronary artery bypass grafting.
Urbanowicz JH; Shaaban MJ; Cohen NH; Cahalan MK; Botvinick EH; Chatterjee K; Schiller NB; Dae MW; Matthay MA
Anesthesiology; 1990 Apr; 72(4):607-12. PubMed ID: 2321775
[TBL] [Abstract][Full Text] [Related]
18. Right ventricular function during orthotopic liver transplantation: three-dimensional transesophageal echocardiography and thermodilution.
Rosendal C; Almamat Uulu K; De Simone R; Wolf I; Deckert A; Martin EO; Böttiger BW; Rauch H
Ann Transplant; 2012; 17(1):21-30. PubMed ID: 22466905
[TBL] [Abstract][Full Text] [Related]
19. Reproducibility of left ventricular volume measurements at rest and during bicycle exercise in patients with congestive heart failure: a combined radionuclide and haemodynamic study.
Wieshammer S; Hetzel M; Hetzel J; Henze E; Clausen M; Hombach V
Nucl Med Commun; 1996 Jul; 17(7):591-5. PubMed ID: 8843118
[TBL] [Abstract][Full Text] [Related]
20. Measurement of left ventricular ejection fraction and volumes with three-dimensional reconstructed transesophageal ultrasound scans: comparison to radionuclide and thermal dilution measurements.
Martin RW; Graham MM; Kao R; Bashein G
J Cardiothorac Anesth; 1989 Jun; 3(3):260-8. PubMed ID: 2562480
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]