These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 87288)

  • 21. Evaluation of enzyme-multiplied immunoassay technique (EMIT) for determination of serum digoxin.
    Rosenthal AF; Vargas MG; Klass CS
    Clin Chem; 1976 Nov; 22(11):1899-902. PubMed ID: 184987
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Spironolactone-associated digoxin radioimmunoassay interference.
    Silber B; Sheiner LB; Powers JL; Winter ME; Sadée W
    Clin Chem; 1979 Jan; 25(1):48-50. PubMed ID: 761378
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Variability among commercially available digoxin radioimmunoassay kits in cross reactivity to dihydrodigoxin.
    Kramer WG; Kinnear NL; Morgan HK
    Clin Chem; 1978 Jan; 24(1):155-7. PubMed ID: 618648
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Factors affecting the radioimmunoassay of digoxin.
    Cerceo E; Elloso CA
    Clin Chem; 1972 Jun; 18(6):539-43. PubMed ID: 5063621
    [No Abstract]   [Full Text] [Related]  

  • 25. Emergency procedure for digoxin radioassay.
    Chen IW; Sperling M; Volle C; Maxon HR
    Clin Chem; 1978 Sep; 24(9):1564-7. PubMed ID: 688618
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Reduced variation of tracer binding in digoxin radioimmunoassay by use of (125I)-labeled tyrosine-methyl-ester derivative: relation of thyroxine concentration to binding.
    Kroening BH; Weintraub M
    Clin Chem; 1976 Oct; 22(10):1732-4. PubMed ID: 975522
    [TBL] [Abstract][Full Text] [Related]  

  • 27. [Sources of error in the radioimmunochemical determination of digoxin in serum].
    Müller H; Graul EH
    Nucl Med (Stuttg); 1975 Dec; 14(4):381-9. PubMed ID: 1215215
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A routine method for the determination of digoxin in urine by radioimmunoassay.
    Christenson RH; Hammond JE; Hull JH; Bustrack JA
    Clin Chim Acta; 1982 Mar; 120(1):13-9. PubMed ID: 7067133
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Radioimmunoassay of serum digoxin levels. Technical aspects (author's transl)].
    Galland F; Gallois Y; Jallet P
    Pathol Biol (Paris); 1981 Oct; 29(8):486-90. PubMed ID: 7029427
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An interlaboratory study of the determination of digoxin by immunoassay.
    Fast DM; Hannon WH; Burtis CA; Bayse DD
    Clin Chem; 1980 Mar; 26(3):480-6. PubMed ID: 6988112
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Sensitive radioimmunoassay for digoxin in plasma and urine.
    Wagner JG; Hallmark MR; Sakmar E; Ayres JW
    Steroids; 1977 Jun; 29(6):787-807. PubMed ID: 910251
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Economical modification of a radioimmunoassay of digoxin with negligible interference from cord and neonatal sera.
    Lee HS; Yeoh TS; Lee AS; Ho NK; Ti TY
    Ther Drug Monit; 1986; 8(3):377-9. PubMed ID: 3750379
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Improvements to the SYVA fluorescence energy transfer immunoassay for digoxin.
    Lehmann DR
    Clin Biochem; 1985 Oct; 18(5):300-3. PubMed ID: 3902286
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Highly specific radioimmunoassay for digoxin using a monoclonal antibody selected for lack of interference by digoxin-like immunoreactive substances in cord blood sera.
    Wahyono D; Piechaczyk M; Scherrmann JM; Girard C; Grenier J; Mani JC; Bastide JM; Pau B
    Ther Drug Monit; 1991 Mar; 13(2):113-9. PubMed ID: 2053117
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Adaptation of the Syva EMIT-cad digoxin enzyme immunoassay technique on the Instrumentation Laboratory Multistat-III microcentrifugal analyzer.
    Alain J; Forest JC
    Ther Drug Monit; 1984; 6(4):489-92. PubMed ID: 6393465
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Combined liquid chromatography/radioimmunoassay with improved specificity for serum digoxin.
    Gault MH; Longerich L; Dawe M; Vasdev SC
    Clin Chem; 1985 Aug; 31(8):1272-7. PubMed ID: 4017230
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of protein concentration on the determination of digoxin in serum by fluorescence polarization immunoassay.
    Porter WH; Haver VM; Bush BA
    Clin Chem; 1984 Nov; 30(11):1826-9. PubMed ID: 6207958
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Development of radioimmunoassay for measurement of serum digoxin in digitalized patients using novel anti-digoxin antiserum.
    Ikeda Y; Araki T; Takimoto H; Fujii Y
    Biol Pharm Bull; 2002 Apr; 25(4):422-5. PubMed ID: 11995917
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Three-years' experience in interlaboratory testing of commercial digoxin kits.
    Hansell JR
    Am J Clin Pathol; 1976 Jul; 66(1):234-7. PubMed ID: 937266
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The inhibition of the primary interaction between 125I-labeled human hemoglobin and rabbit anti-human hemoglobin sera: a sensitive radioimmunoassay technique.
    Garver FA
    J Immunol Methods; 1975 Jun; 7(2-3):271-82. PubMed ID: 1170236
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.