These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

146 related articles for article (PubMed ID: 8735090)

  • 1. Flow cytometric immunofluorescence assay for detection of antibodies to human immunodeficiency virus type 1 using insoluble precursor forms of recombinant polyproteins as carriers and antigens.
    Hu YW; Birch P; Balaskas E; Zeibdawi A; Scalia V; Thériault-Valin SA; Gill P; Aye MT
    J Clin Microbiol; 1996 Jun; 34(6):1412-9. PubMed ID: 8735090
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Early detection of antibodies against rDNA-produced HIV proteins with a flow cytometric assay.
    Scillian JJ; McHugh TM; Busch MP; Tam M; Fulwyler MJ; Chien DY; Vyas GN
    Blood; 1989 May; 73(7):2041-8. PubMed ID: 2540862
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Detection of binding antibodies to native and recombinant human immunodeficiency virus type 1 envelope glycoproteins following recombinant gp160 immunization measured by flow cytometry and enzyme immunoassays. The AIDS Vaccine Clinical Trials Network.
    Gorse GJ; Frey SE; Newman FK; Belshe RB
    J Clin Microbiol; 1992 Oct; 30(10):2606-12. PubMed ID: 1400960
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Earlier detection of human immunodeficiency virus type 1 p24 antigen and immunoglobulin G and M antibodies to p17 antigen in seroconversion serum panels by immune complex transfer enzyme immunoassays.
    Hashida S; Ishikawa S; Hashinaka K; Nishikata I; Oka S; Ishikawa E
    Clin Diagn Lab Immunol; 2000 Nov; 7(6):872-81. PubMed ID: 11063490
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Enzyme immunoassay using native envelope glycoprotein (gp160) for detection of human immunodeficiency virus type 1 antibodies.
    Nair BC; Ford G; Kalyanaraman VS; Zafari M; Fang C; Sarngadharan MG
    J Clin Microbiol; 1994 Jun; 32(6):1449-56. PubMed ID: 8077388
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bacterially expressed core and envelope proteins of human immunodeficiency virus type-1 (HIV-1): comparative evaluation in detection of type-specific antibodies.
    Kovác J; Zachar V; Brůcková M; Ujhélyi E; Füst G; Mayer V; Zajac V
    Acta Virol; 1992 Aug; 36(4):337-46. PubMed ID: 1282776
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flow cytometric indirect immunofluorescence assay with high sensitivity and specificity for detection of antibodies to human immunodeficiency virus (HIV).
    Sligh JM; Roodman ST; Tsai CC
    Am J Clin Pathol; 1989 Feb; 91(2):210-4. PubMed ID: 2644808
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance characteristics of recombinant enzyme immunoassay to detect antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 and to measure early antibody responses in seroconverting patients.
    Galli RA; Castriciano S; Fearon M; Major C; Choi KW; Mahony J; Chernesky M
    J Clin Microbiol; 1996 Apr; 34(4):999-1002. PubMed ID: 8815130
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a flow cytometric assay for the detection and measurement of neutralizing antibodies against human immunodeficiency virus.
    Folghera S; Fiorentini S; Martinelli F; Ravizzola G; Gargiulo F; Terlenghi L; De Francesco M; Caruso A; Turano A
    New Microbiol; 1994 Jan; 17(1):21-8. PubMed ID: 8127226
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Vaccine-induced antibodies to native and recombinant human immunodeficiency virus type 1 envelope glycoproteins. NIAID AIDS Vaccine Clinical Trials Network.
    Gorse GJ; Frey SE; Patel G; Newman FK; Belshe RB
    Vaccine; 1994 Aug; 12(10):912-8. PubMed ID: 7975833
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a new combined antigen and antibody human immunodeficiency virus screening assay, VIDAS HIV DUO Ultra.
    Weber B; Berger A; Rabenau H; Doerr HW
    J Clin Microbiol; 2002 Apr; 40(4):1420-6. PubMed ID: 11923367
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sensitivity of HIV-antibody assays determined by seroconversion panels.
    Constantine NT; van der Groen G; Belsey EM; Tamashiro H
    AIDS; 1994 Dec; 8(12):1715-20. PubMed ID: 7888121
    [TBL] [Abstract][Full Text] [Related]  

  • 13. More reliable diagnosis of infection with human immunodeficiency virus type 1 (HIV-1) by detection of antibody IgGs to pol and gag proteins of HIV-1 and p24 antigen of HIV-1 in urine, saliva, and/or serum with highly sensitive and specific enzyme immunoassay (immune complex transfer enzyme immunoassay): a review.
    Hashida S; Hashinaka K; Ishikawa S; Ishikawa E
    J Clin Lab Anal; 1997; 11(5):267-86. PubMed ID: 9292394
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of a rapid immunochromatographic test for detection of antibodies to human immunodeficiency virus.
    Arai H; Petchclai B; Khupulsup K; Kurimura T; Takeda K
    J Clin Microbiol; 1999 Feb; 37(2):367-70. PubMed ID: 9889220
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Serum antibodies to HIV-1 in recombinant vaccinia virus recipients boosted with purified recombinant gp160. NIAID AIDS Vaccine Clinical Trials Network.
    Montefiori DC; Graham BS; Kliks S; Wright PF
    J Clin Immunol; 1992 Nov; 12(6):429-39. PubMed ID: 1287035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reactivity of a new HIV-1 group O third generation A-HIV-1/-2 assay with an unusual HIV-1 seroconversion panel and HIV-1 group O/group M subtyped samples.
    van Binsbergen J; Keur W; vd Graaf M; Siebelink A; Jacobs A; de Rijk D; Toonen J; Zekeng L; Afane Ze E; Gürtler LG
    J Virol Methods; 1997 Dec; 69(1-2):29-37. PubMed ID: 9504748
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Radioimmune western blotting in comparison with conventional western blotting, second and third generation ELISA assays for the serodiagnosis of HIV-1 infection.
    Portincasa P; Conti G; Zannino T; Visalli S; Chezzi C
    New Microbiol; 1994 Jul; 17(3):169-76. PubMed ID: 7968651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A combined HIV-1 protein bead array for serology assay and T-cell subset immunophenotyping with a hybrid flow cytometer: a step in the direction of a comprehensive multitasking instrument platform for infectious disease diagnosis and monitoring.
    Faucher S; Martel A; Sherring A; Bogdanovic D; Malloch L; Kim JE; Bergeron M; Sandstrom P; Mandy FF
    Cytometry B Clin Cytom; 2006 May; 70(3):179-88. PubMed ID: 16615079
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Recombinant p51 as antigen in an immune complex transfer enzyme immunoassay of immunoglobulin G antibody to human immunodeficiency virus type 1.
    Hashinaka K; Hashida S; Nishikata I; Adachi A; Oka S; Ishikawa E
    Clin Diagn Lab Immunol; 2000 Nov; 7(6):967-76. PubMed ID: 11063508
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative detection of human immunodeficiency virus (HIV) antigen by the Enzymun-Test: comparison with alternative assays and nucleic acid sequence-based amplification of HIV type 1 RNA.
    Weber B; Melchior W; Preiser W; Hess G; Wahl M; Braner J; Doerr HW
    J Clin Microbiol; 1996 Jun; 34(6):1440-7. PubMed ID: 8735095
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.