3. Tachycardia detection in modern implantable cardioverter-defibrillators. Brüggemann T; Dahlke D; Chebbo A; Neumann I Herzschrittmacherther Elektrophysiol; 2016 Sep; 27(3):171-85. PubMed ID: 27576695 [TBL] [Abstract][Full Text] [Related]
4. Clinical relevance of stored electrograms for implantable cardioverter-defibrillator (ICD) troubleshooting and understanding of mechanisms for ventricular tachyarrhythmias. Auricchio A; Hartung W; Geller C; Klein H Am J Cardiol; 1996 Sep; 78(5A):33-41. PubMed ID: 8820834 [TBL] [Abstract][Full Text] [Related]
8. Discrimination between ventricular and supraventricular tachycardia by dual chamber cardioverter defibrillators: importance of the atrial sensing function. Israel CW; Grönefeld G; Iscolo N; Stöppler C; Hohnloser SH Pacing Clin Electrophysiol; 2001 Feb; 24(2):183-90. PubMed ID: 11270697 [TBL] [Abstract][Full Text] [Related]
9. Sensing and detection in Medtronic implantable cardioverter defibrillators. Brown ML; Swerdlow CD Herzschrittmacherther Elektrophysiol; 2016 Sep; 27(3):193-212. PubMed ID: 27624809 [TBL] [Abstract][Full Text] [Related]
10. Underdetection of ventricular tachycardia by algorithms to enhance specificity in a tiered-therapy cardioverter-defibrillator. Swerdlow CD; Ahern T; Chen PS; Hwang C; Gang E; Mandel W; Kass RM; Peter CT J Am Coll Cardiol; 1994 Aug; 24(2):416-24. PubMed ID: 8034878 [TBL] [Abstract][Full Text] [Related]
11. Avoiding inappropriate ventricular tachycardia detection due to T-wave oversensing in an implantable cardioverter defibrillator: a novel application of the electrogram width criterion. Duru F; Bauersfeld U; Candinas R Europace; 2001 Jan; 3(1):80-4. PubMed ID: 11271957 [TBL] [Abstract][Full Text] [Related]
12. Undersensing during ventricular tachyarrhythmias in a third-generation implantable cardioverter defibrillator: diagnosis using stored electrograms and correction with programming. Mann DE; Kelly PA; Damle RS; Reiter MJ Pacing Clin Electrophysiol; 1994 Sep; 17(9):1525-30. PubMed ID: 7991424 [TBL] [Abstract][Full Text] [Related]
13. Prevention of inappropriate therapy in implantable cardioverter-defibrillators: results of a prospective, randomized study of tachyarrhythmia detection algorithms. Theuns DA; Klootwijk AP; Goedhart DM; Jordaens LJ J Am Coll Cardiol; 2004 Dec; 44(12):2362-7. PubMed ID: 15607399 [TBL] [Abstract][Full Text] [Related]
14. Detection and discrimination of tachycardia in ICDs manufactured by St. Jude Medical. Zdarek J; Israel CW Herzschrittmacherther Elektrophysiol; 2016 Sep; 27(3):226-39. PubMed ID: 27605236 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators. Theuns DA; Rivero-Ayerza M; Goedhart DM; van der Perk R; Jordaens LJ Heart Rhythm; 2006 Nov; 3(11):1332-8. PubMed ID: 17074640 [TBL] [Abstract][Full Text] [Related]
16. Is inappropriate therapy a resolved issue with current implantable cardioverter defibrillators? Brugada J Am J Cardiol; 1999 Mar; 83(5B):40D-44D. PubMed ID: 10089838 [TBL] [Abstract][Full Text] [Related]
17. Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis. Hook BG; Callans DJ; Kleiman RB; Flores BT; Marchlinski FE Circulation; 1993 Jun; 87(6):1897-906. PubMed ID: 8504502 [TBL] [Abstract][Full Text] [Related]
18. Inappropriate disabling of an ICD noise-detection algorithm in pacemaker-dependent patients. Welte N; Gang ES; Swerdlow CD; Strik M; Bordachar P; Ploux S Pacing Clin Electrophysiol; 2019 Apr; 42(4):478-482. PubMed ID: 30515880 [TBL] [Abstract][Full Text] [Related]
19. Inappropriate discharge by an implantable cardioverter defibrillator: recognition of myopotential sensing using telemetered intracardiac electrograms. Sandler MJ; Kutalek SP Pacing Clin Electrophysiol; 1994 Apr; 17(4 Pt 1):665-71. PubMed ID: 7516548 [TBL] [Abstract][Full Text] [Related]
20. Sensing and Detection Functions in Implantable Cardioverter Defibrillators: The Good, the Bad and the Ugly. Kossaify A Acta Cardiol Sin; 2020 Jul; 36(4):308-317. PubMed ID: 32675922 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]