129 related articles for article (PubMed ID: 8748734)
1. Sample self-stacking and sample stacking in zone electrophoresis with major sample components of like charge: general model and scheme of possible modes.
Gebauer P; Thormann W; Bocek P
Electrophoresis; 1995 Nov; 16(11):2039-50. PubMed ID: 8748734
[TBL] [Abstract][Full Text] [Related]
2. Sample self-stacking in capillary zone electrophoresis: behavior of samples containing multiple major coionic components.
Gebauer P; Krivánková L; Pantůcková P; Bocek P; Thormann W
Electrophoresis; 2000 Aug; 21(14):2797-808. PubMed ID: 11001286
[TBL] [Abstract][Full Text] [Related]
3. System peaks in capillary zone electrophoresis. 3. Practical rules for predicting the existence of system peaks in capillary zone electrophoresis of anions using indirect spectrophotometric detection.
Macka M; Haddad PR; Gebauer P; Bocek P
Electrophoresis; 1997 Oct; 18(11):1998-2007. PubMed ID: 9420159
[TBL] [Abstract][Full Text] [Related]
4. Scaling behavior in on-chip field-amplified sample stacking.
Dubey K; Gupta A; Bahga SS
Electrophoresis; 2019 Mar; 40(5):730-739. PubMed ID: 30628102
[TBL] [Abstract][Full Text] [Related]
5. Change of migration time and separation window accompanied by field-enhanced sample stacking in capillary zone electrophoresis.
Hirokawa T; Ikuta N; Yoshiyama T; Okamoto H
Electrophoresis; 2001 Oct; 22(16):3444-8. PubMed ID: 11669524
[TBL] [Abstract][Full Text] [Related]
6. Eigenmobilities in background electrolytes for capillary zone electrophoresis: II. Eigenpeaks in univalent weak electrolytes.
Stedrý M; Jaros M; Vceláková K; Gas B
Electrophoresis; 2003 Jan; 24(3):536-47. PubMed ID: 12569543
[TBL] [Abstract][Full Text] [Related]
7. Influence of ignored and well-known zone distortions on the separation performance of proteins in capillary free zone electrophoresis with special reference to analysis in polyacrylamide-coated fused silica capillaries in various buffers. I. Theoretical studies.
Hjertén S; Mohabbati S; Westerlund D
J Chromatogr A; 2004 Oct; 1053(1-2):181-99. PubMed ID: 15543984
[TBL] [Abstract][Full Text] [Related]
8. Chloride present in biological samples as a tool for enhancement of sensitivity in capillary zone electrophoretic analysis of anionic trace analytes.
Krivánková L; Pantůcková P; Gebauer P; Bocek P; Caslavska J; Thormann W
Electrophoresis; 2003 Jan; 24(3):505-17. PubMed ID: 12569541
[TBL] [Abstract][Full Text] [Related]
9. Sample stacking of cationic and anionic analytes in capillary electrophoresis.
Quirino JP; Terabe S
J Chromatogr A; 2000 Dec; 902(1):119-35. PubMed ID: 11192151
[TBL] [Abstract][Full Text] [Related]
10. Unusual stacking with electrokinetic injection of cationic analytes from micellar solutions in capillary zone electrophoresis.
Wuethrich A; Quirino JP
Anal Bioanal Chem; 2016 Dec; 408(30):8663-8668. PubMed ID: 27372717
[TBL] [Abstract][Full Text] [Related]
11. A new type of migrating zone boundary in electrophoresis: 3. The hybrid boundary and stacking criteria.
Gebauer P; Malá Z; Bocek P
Electrophoresis; 2006 Mar; 27(5-6):962-7. PubMed ID: 16470780
[TBL] [Abstract][Full Text] [Related]
12. Theory of zone separation in isotachophoresis: a diffusional approach.
Gebauer P; Bocek P
Electrophoresis; 1995 Nov; 16(11):1999-2007. PubMed ID: 8748729
[TBL] [Abstract][Full Text] [Related]
13. Three-step stacking by field-enhanced sample injection, sweeping, and micelle to solvent stacking in capillary electrophoresis: Anionic analytes.
Grochocki W; Markuszewski MJ; Quirino JP
J Chromatogr A; 2016 Apr; 1442():140-3. PubMed ID: 27000740
[TBL] [Abstract][Full Text] [Related]
14. Sample stacking in CZE using dynamic thermal junctions II: analytes with high dpKa/dT crossing a single thermal junction in a BGE with low dpH/dT.
Mandaji M; Rübensam G; Hoff RB; Hillebrand S; Carrilho E; Kist TL
Electrophoresis; 2009 May; 30(9):1510-5. PubMed ID: 19350542
[TBL] [Abstract][Full Text] [Related]
15. Conductivity detection in capillary zone electrophoresis: inspection by PeakMaster.
Jaros M; Soga T; van de Goor T; Gas B
Electrophoresis; 2005 May; 26(10):1948-53. PubMed ID: 15818577
[TBL] [Abstract][Full Text] [Related]
16. Sample stacking in CZE using dynamic thermal junctions I. Analytes with low dpKa/dT crossing a single thermally induced pH junction in a BGE with high dpH/dT.
Mandaji M; Rübensam G; Hoff RB; Hillebrand S; Carrilho E; Kist TL
Electrophoresis; 2009 May; 30(9):1501-9. PubMed ID: 19350541
[TBL] [Abstract][Full Text] [Related]
17. Quantitation of trace analytes in capillary zone electrophoresis with UV-absorbance detection: a critical study of approaches based on peak height.
Krivánková L; Gebauer P; Pantůcková P; Bocek P
Electrophoresis; 2002 Jun; 23(12):1833-43. PubMed ID: 12116126
[TBL] [Abstract][Full Text] [Related]
18. Investigation of the mechanism of pH-mediated stacking of anions for the analysis of physiological samples by capillary electrophoresis.
Arnett SD; Lunte CE
Electrophoresis; 2003 Jun; 24(11):1745-52. PubMed ID: 12783451
[TBL] [Abstract][Full Text] [Related]
19. The preparation of background electrolytes in capillary zone electrophoresis: golden rules and pitfalls.
Beckers JL; Bocek P
Electrophoresis; 2003 Jan; 24(3):518-35. PubMed ID: 12569542
[TBL] [Abstract][Full Text] [Related]
20. Anionic microemulsion to solvent stacking for on-line sample concentration of cationic analytes in capillary electrophoresis.
Kukusamude C; Srijaranai S; Quirino JP
Electrophoresis; 2014 May; 35(10):1478-83. PubMed ID: 24519645
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]