These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 8750128)

  • 1. Superimposed inspiratory work of the Siemens Servo 300 ventilator during continuous positive airway pressure.
    Tan IK; Bhatt SB; Tam YH; Buckley TA; Oh TE
    Intensive Care Med; 1995 Dec; 21(12):1023-6. PubMed ID: 8750128
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Respiratory muscle performance, pulmonary mechanics, and gas exchange between the BiPAP S/T-D system and the Servo Ventilator 900C with bilevel positive airway pressure ventilation following gradual pressure support weaning.
    Patel RG; Petrini MF
    Chest; 1998 Nov; 114(5):1390-6. PubMed ID: 9824020
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ventilator-CPAP with the Siemens Servo 900C compared with continuous flow-CPAP in intubated patients: effect on work of breathing.
    Aerts JG; van den Berg B; Bogaard JM
    Anaesth Intensive Care; 1997 Oct; 25(5):487-92. PubMed ID: 9352760
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of different triggering systems and external PEEP on trigger capability of the ventilator.
    Konyukov YA; Kuwayama N; Fukuoka T; Takahashi T; Mayumi T; Hotta T; Takezawa J
    Intensive Care Med; 1996 Apr; 22(4):363-8. PubMed ID: 8708177
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Work of breathing, inspiratory flow response, and expiratory resistance during continuous positive airway pressure with the ventilators EVITA-2, EVITA-4 and SV 300.
    Calzia E; Lindner KH; Stahl W; Martin A; Radermacher P; Georgieff M
    Intensive Care Med; 1998 Sep; 24(9):931-8. PubMed ID: 9803329
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Characteristics of the ventilator pressure- and flow-trigger variables.
    Sassoon CS; Gruer SE
    Intensive Care Med; 1995 Feb; 21(2):159-68. PubMed ID: 7775698
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved flow and pressure capabilities of the Datex-Ohmeda SmartVent anesthesia ventilator.
    Katz JA; Kallet RH; Alonso JA; Marks JD
    J Clin Anesth; 2000 Feb; 12(1):40-7. PubMed ID: 10773507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. An evaluation of Automode, a computer-controlled ventilator mode, with the Siemens Servo 300A ventilator, using a porcine model.
    Holt SJ; Sanders RC; Thurman TL; Heulitt MJ
    Respir Care; 2001 Jan; 46(1):26-36. PubMed ID: 11175235
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Quantitative comparison of ventilator-induced work during simulated CPAP in eight demand-flow valve ventilators].
    Nishimura M; Imanaka H; Taenaka N; Yoshiya I; Takezawa J
    Masui; 1989 Aug; 38(8):1017-29. PubMed ID: 2681861
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Adapting the Bird Mark 7 to deliver noninvasive continuous positive airway pressure: a bench study.
    Kikuti BM; Utsunomia K; Colaneri RP; Carvalho CR; Caruso P
    J Bras Pneumol; 2008 Mar; 34(3):167-72. PubMed ID: 18392465
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of total resistive work of breathing in two generations of ventilators in an animal model.
    Heulitt MJ; Torres A; Anders M; Wilson SW; Carmack J
    Pediatr Pulmonol; 1996 Jul; 22(1):58-66. PubMed ID: 8856804
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Tracheal pressure triggering a demand-flow continuous positive airway pressure system decreases patient work of breathing.
    Messinger G; Banner MJ
    Crit Care Med; 1996 Nov; 24(11):1829-34. PubMed ID: 8917033
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effect of ventilator performance on airway pressure release ventilation: a model lung study.
    Yoshida T; Uchiyama A; Mashimo T; Fujino Y
    Anesth Analg; 2011 Sep; 113(3):529-33. PubMed ID: 21519042
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of pressure support ventilation with seven different ventilators using Active Servo Lung 5000.
    Terado M; Ichiba S; Nagano O; Ujike Y
    Acta Med Okayama; 2008 Apr; 62(2):127-33. PubMed ID: 18464889
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative bench study of triggering, pressurization, and cycling between the home ventilator VPAP II and three ICU ventilators.
    Tassaux D; Strasser S; Fonseca S; Dalmas E; Jolliet P
    Intensive Care Med; 2002 Sep; 28(9):1254-61. PubMed ID: 12209273
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Total inspiratory work with modern demand valve devices compared to continuous flow CPAP.
    Samodelov LF; Falke KJ
    Intensive Care Med; 1988; 14(6):632-9. PubMed ID: 3053843
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pressure support and pressure assist/control: are there differences? An evaluation of the newest intensive care unit ventilators.
    Williams P; Kratohvil J; Ritz R; Hess DR; Kacmarek RM
    Respir Care; 2000 Oct; 45(10):1169-81. PubMed ID: 11054896
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical ventilators optimized for pediatric use decrease work of breathing and oxygen consumption during pressure-support ventilation.
    el-Khatib MF; Chatburn RL; Potts DL; Blumer JL; Smith PG
    Crit Care Med; 1994 Dec; 22(12):1942-8. PubMed ID: 7988130
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Flow-triggering reduces inspiratory effort during weaning from mechanical ventilation.
    Polese G; Massara A; Poggi R; Brandolese R; Brandi G; Rossi A
    Intensive Care Med; 1995 Aug; 21(8):682-6. PubMed ID: 8522675
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Imposed work of breathing and methods of triggering a demand-flow, continuous positive airway pressure system.
    Banner MJ; Blanch PB; Kirby RR
    Crit Care Med; 1993 Feb; 21(2):183-90. PubMed ID: 8428467
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.