BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

119 related articles for article (PubMed ID: 8751416)

  • 1. A simple and generally applicable method to estimate the peripheral dose in radiation teletherapy with high energy x-rays or gamma radiation.
    Van der Giessen PH
    Int J Radiat Oncol Biol Phys; 1996 Jul; 35(5):1059-68. PubMed ID: 8751416
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Collimator-related radiation dose for different cobalt machines and linear accelerators.
    van der Giessen PH
    Int J Radiat Oncol Biol Phys; 1996 May; 35(2):399-405. PubMed ID: 8635949
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Peripheral dose from megavolt beams.
    Fraass BA; van de Geijn J
    Med Phys; 1983; 10(6):809-18. PubMed ID: 6419031
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Clinic based transfer of the N(D,W)(60Co) calibration coefficient using a linear accelerator.
    Abdel-Rahman W; Evans MD; Serré L; McCaffrey JP; Podgorsak EB; Seuntjens JP
    Med Phys; 2009 Mar; 36(3):929-38. PubMed ID: 19378753
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dose in the buildup region outside the primary beam.
    Horton JL
    Med Phys; 1984; 11(3):331-4. PubMed ID: 6429500
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Peripheral dose measurements for 6 and 18 MV photon beams on a linear accelerator with multileaf collimator.
    Mazonakis M; Zacharopoulou F; Varveris H; Damilakis J
    Med Phys; 2008 Oct; 35(10):4396-403. PubMed ID: 18975685
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Impact of Radiation Energy on Dose Homogeneity and Organ Dose in the Göttingen Minipig Total-Body Irradiation Model.
    Poirier Y; Becker S; Decesaris C; Culberson W; Draeger E; Gerry AJ; Johnstone CD; Gibbs A; Vujaskovic Z; Jackson IL
    Radiat Res; 2020 Nov; 194(5):544-556. PubMed ID: 33045066
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A Monte Carlo study on internal wedges using BEAM.
    van der Zee W; Welleweerd J
    Med Phys; 2002 May; 29(5):876-85. PubMed ID: 12033584
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Calculation and measurement of the dose at points outside the primary beam for photon energies of 6, 10, and 23 MV.
    van der Giessen PH
    Int J Radiat Oncol Biol Phys; 1994 Dec; 30(5):1239-46. PubMed ID: 7961034
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Modeling scatter-to-primary dose ratio for megavoltage photon beams.
    Wang KK; Zhu TC
    Med Phys; 2010 Oct; 37(10):5270-8. PubMed ID: 21089761
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A study of dose distribution patterns from cobalt-60 and Varian Clinac-4 beams.
    Nair R; Kartha M
    AJR Am J Roentgenol; 1978 Jan; 130(1):150-3. PubMed ID: 413401
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Interface dose perturbation as a measure of megavoltage photon beam energy.
    Das IJ; Khan FM; Gerbi BJ
    Med Phys; 1988; 15(1):78-81. PubMed ID: 3127666
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Physical characterization of single convergent beam device for teletherapy: theoretical and Monte Carlo approach.
    Figueroa RG; Valente M
    Phys Med Biol; 2015 Sep; 60(18):7191-206. PubMed ID: 26348025
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An equivalent square method for irregular photon fields.
    Monti AF; Ostinelli A; Frigerio M; Gelosa S
    Med Dosim; 1995; 20(4):275-7. PubMed ID: 8703323
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation-induced hemopoietic death in mice as a function of photon energy and dose rate.
    Gengozian N; Taylor T; Jameson H; Lee ET; Good RA; Epstein RB
    Radiat Res; 1986 Mar; 105(3):320-7. PubMed ID: 3961097
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Peak scatter factors for high energy photon beams.
    Li XA
    Med Phys; 1999 Jun; 26(6):962-6. PubMed ID: 10436898
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Surface dose for megavoltage photon beams outside the treatment field.
    Starkschall G; St George FJ; Zellmer DL
    Med Phys; 1983; 10(6):906-10. PubMed ID: 6419036
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experimental determination of beam quality conversion factors k(Q) in clinical photon beams using ferrous sulphate (Fricke) dosimetry.
    Palm A; Mattsson O
    Med Phys; 2002 Dec; 29(12):2756-62. PubMed ID: 12512708
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measurement of the peripheral dose for the tangential breast treatment technique with Co-60 gamma radiation and high energy X-rays.
    Van der Giessen PH
    Radiother Oncol; 1997 Mar; 42(3):257-64. PubMed ID: 9155075
    [TBL] [Abstract][Full Text] [Related]  

  • 20. "Zero-field" dose data for 60Co and other high-energy photon beams in water.
    Nizin P; Qian GX; Rashid H
    Med Phys; 1993; 20(5):1353-60. PubMed ID: 8289716
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.