These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

89 related articles for article (PubMed ID: 875430)

  • 1. Implantable artificial lung. Preliminary report.
    Morin PJ; Gosselin C; Picard R; Vincent M; Guidoin R; Nicholl CI
    J Thorac Cardiovasc Surg; 1977 Jul; 74(1):130-6. PubMed ID: 875430
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Landé-Edwards membrane oxygenator without pump as total lung prosthesis.
    Vanderhoeft P; Derks C; de Francquen P; Rozencwajg J
    J Thorac Cardiovasc Surg; 1975 Feb; 69(2):196-202. PubMed ID: 234555
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Artificial "membranous lung"].
    Pisarevskiĭ AA; Doletskiĭ AS; Kutepov PV; Karasev AB
    Med Tekh; 1976; (4):44-50. PubMed ID: 799747
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Development of an implantable artificial lung.
    Palmer AS; Collins J; Head LR
    J Thorac Cardiovasc Surg; 1973 Oct; 66(4):521-5. PubMed ID: 4755443
    [No Abstract]   [Full Text] [Related]  

  • 5. Development of an intravenous membrane oxygenator: a new concept in mechanical support for the failing lung.
    Hattler BG; Reeder GD; Sawzik PJ; Walters FR; Pham SM; Kormos RL; Keenan RJ; Griffith BP; Armitage JM; Hardesty RL
    J Heart Lung Transplant; 1994; 13(6):1003-8. PubMed ID: 7865505
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Use of a membrane oxygenator in respiratory assistance. I. Evaluation of the in vitro characteristics of the apparatus before use with blood].
    Gille JP; Baillot M
    Bull Physiopathol Respir (Nancy); 1972; 8(1):7-28. PubMed ID: 4559557
    [No Abstract]   [Full Text] [Related]  

  • 7. The toroidal membrane oxygenator: design, performance, and prolonged bypass testing of a clinical model.
    Bartlett RH; Drinker PA; Burns NE; Fong SW; Hyans T
    Trans Am Soc Artif Intern Organs; 1972; 18(0):369-74. PubMed ID: 4679890
    [No Abstract]   [Full Text] [Related]  

  • 8. Bridge to lung transplantation through a pulmonary artery to left atrial oxygenator circuit.
    Schmid C; Philipp A; Hilker M; Arlt M; Trabold B; Pfeiffer M; Schmid FX
    Ann Thorac Surg; 2008 Apr; 85(4):1202-5. PubMed ID: 18355495
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies.
    Zierenberg JR; Fujioka H; Cook KE; Grotberg JB
    J Biomech Eng; 2008 Jun; 130(3):031019. PubMed ID: 18532868
    [TBL] [Abstract][Full Text] [Related]  

  • 10. First experience with a paracorporeal artificial lung in humans.
    Camboni D; Philipp A; Arlt M; Pfeiffer M; Hilker M; Schmid C
    ASAIO J; 2009; 55(3):304-6. PubMed ID: 19282751
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of an implantable oxygenator with cross-flow pump.
    Asakawa Y; Funakubo A; Fukunaga K; Taga I; Higami T; Kawamura T; Fukui Y
    ASAIO J; 2006; 52(3):291-5. PubMed ID: 16760718
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Development of a novel artificial heart-lung system for long-term cardiopulmonary support--experimental evaluation in goats with total cardiopulmonary bypass].
    Eya K
    Hokkaido Igaku Zasshi; 1999 Sep; 74(5):395-404. PubMed ID: 10495854
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of a MedArray silicone hollow fiber oxygenator.
    LaFayette NG; Schewe RE; Montoya JP; Cook KE
    ASAIO J; 2009; 55(4):382-7. PubMed ID: 19381081
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [The use of a membrane oxygenator in respiratory assistance. II. Animal experiments and therapeutic trials of CO 2 removal in respiratory insufficiency].
    Gille JP; Gautier P; Horsky P; Sadoul P
    Bull Physiopathol Respir (Nancy); 1972; 8(1):29-48. PubMed ID: 5052520
    [No Abstract]   [Full Text] [Related]  

  • 15. Development of a new silicone membrane oxygenator for ECMO.
    Nakata K; Maeda T; Murabayashi S; Yoshikawa M; Takano T; Iwasaki A; Nonaka K; Linneweber J; Kawahito S; Glueck J; Sato K; Kuwana J; Nosé Y
    Ann Thorac Cardiovasc Surg; 2000 Dec; 6(6):373-7. PubMed ID: 11173351
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A microfluidic respiratory assist device with high gas permeance for artificial lung applications.
    Kniazeva T; Hsiao JC; Charest JL; Borenstein JT
    Biomed Microdevices; 2011 Apr; 13(2):315-23. PubMed ID: 21113664
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new gas permeable membrane for blood oxygenators.
    Eiseman B; Birnbaum D; Leonard R; Martinez FJ
    Surg Gynecol Obstet; 1972 Nov; 135(5):732-6. PubMed ID: 5084244
    [No Abstract]   [Full Text] [Related]  

  • 18. Comparing oxygen transfer performance between three membrane oxygenators: effect of temperature changes during cardiopulmonary bypass.
    Jegger D; Tevaearai HT; Mallabiabarrena I; Horisberger J; Seigneul I; von Segesser LK
    Artif Organs; 2007 Apr; 31(4):290-300. PubMed ID: 17437498
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Artificial lung: current perspectives.
    Go T; Macchiarini P
    Minerva Chir; 2008 Oct; 63(5):363-72. PubMed ID: 18923347
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Functional and biocompatibility performances of an integrated Maglev pump-oxygenator.
    Zhang T; Cheng G; Koert A; Zhang J; Gellman B; Yankey GK; Satpute A; Dasse KA; Gilbert RJ; Griffith BP; Wu ZJ
    Artif Organs; 2009 Jan; 33(1):36-45. PubMed ID: 19178439
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.