These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 8760514)

  • 1. [Use of low temperature methods with optically stimulated luminescence for measuring ionizing radiation doses].
    Jankowski J; Błaszczyk M
    Med Pr; 1996; 47(3):293-302. PubMed ID: 8760514
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Blue light stimulated luminescence in calcium fluoride, its characteristics and implications in radiation dosimetry.
    Chougaonkar MP; Bhatt BC
    Radiat Prot Dosimetry; 2004; 112(2):311-21. PubMed ID: 15353604
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optically stimulated luminescence dosimetry performance of natural Brazilian topaz exposed to beta radiation.
    Bernal R; Souza DN; Valerio ME; Cruz-Vázquez C; Barboza-Flores M
    Radiat Prot Dosimetry; 2006; 119(1-4):161-3. PubMed ID: 16735557
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intercomparison of dosimetry systems based on CaF2:Mn TL detectors.
    Zorko B; Miljanić S; Vekić B; Stuhec M; Gobec S; Ranogajec-Komor M
    Radiat Prot Dosimetry; 2006; 119(1-4):300-5. PubMed ID: 16735564
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Independent evaluation of optically stimulated luminescence (OSL) 'dot' dosemeters for environmental monitoring.
    Timilsina B; Gesell TF
    Radiat Prot Dosimetry; 2011 Jan; 143(1):27-32. PubMed ID: 20947590
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [New dosimetry system based on the thermoluminescence method for evaluation of ionizing radiation doses to workers of the health centers].
    Urban P; Skubacz K
    Wiad Lek; 2015; 68(1):71-8. PubMed ID: 26094337
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Identification of static exposure of standard dosimetric badge with thermoluminescent detectors.
    Budzanowski M; Olko P; Kopeć R; Obryk B; Dzikiewicz-Sapiecha H; Siwicki R
    Radiat Prot Dosimetry; 2007; 125(1-4):213-6. PubMed ID: 17038405
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Performance of CVD diamond as an optically and thermally stimulated luminescence dosemeter.
    Preciado-Flores S; Schreck M; Meléndrez R; Chernov V; Bernal R; Cruz-Vázquez C; Cruz-Zaragoza E; Barboza-Flores M
    Radiat Prot Dosimetry; 2006; 119(1-4):226-9. PubMed ID: 16585260
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ionisation density dependence of the optically and thermally stimulated luminescence from Al2O3:C.
    Yukihara EG; McKeever SW
    Radiat Prot Dosimetry; 2006; 119(1-4):206-17. PubMed ID: 16585262
    [TBL] [Abstract][Full Text] [Related]  

  • 10. High-precision dosimetry for radiotherapy using the optically stimulated luminescence technique and thin Al2O3:C dosimeters.
    Yukihara EG; Yoshimura EM; Lindstrom TD; Ahmad S; Taylor KK; Mardirossian G
    Phys Med Biol; 2005 Dec; 50(23):5619-28. PubMed ID: 16306656
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thermoluminescence glow curves and optical stimulated luminescence of undoped alpha-Al2O3 crystals.
    Zhang CX; Tang Q; Lin LB; Luo DL
    Radiat Prot Dosimetry; 2006; 119(1-4):402-7. PubMed ID: 16644982
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:C.
    Marckmann CJ; Andersen CE; Aznar MC; Bøtter-Jensen L
    Radiat Prot Dosimetry; 2006; 120(1-4):28-32. PubMed ID: 16762966
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optical and dosimetric properties of zircon.
    Kristianpoller N; Weiss D; Chen R
    Radiat Prot Dosimetry; 2006; 119(1-4):267-70. PubMed ID: 16702245
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preliminary OSL studies on beige sepiolites.
    Bulur E
    Radiat Prot Dosimetry; 2008; 131(3):390-3. PubMed ID: 18583371
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The use of computerised glow curve analysis will optimise personal thermoluminescence dosimetry measurements. Opposing the proposition.
    Pradhan AS; Yoder RC
    Radiat Prot Dosimetry; 2002; 102(3):274-7. PubMed ID: 12430967
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thermally stimulated luminescence and EPR studies on topaz.
    Souza DN; de Lima JF; Valerio ME; Caldas LV
    Appl Radiat Isot; 2006 Aug; 64(8):906-9. PubMed ID: 16701998
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optically and thermally stimulated luminescence characteristics of MgO:Tb3+.
    Bos AJ; Prokić M; Brouwer JC
    Radiat Prot Dosimetry; 2006; 119(1-4):130-3. PubMed ID: 16644952
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Preliminary thermoluminescence and optically stimulated luminescence investigation of commercial pharmaceutical preparations towards the drug sterilization dosimetry.
    Kazakis NA; Tsirliganis NC; Kitis G
    Appl Radiat Isot; 2014 Sep; 91():79-91. PubMed ID: 24922552
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A system to irradiate and measure luminescence at low temperatures.
    Blair MW; Yukihara EG; McKeever SW
    Radiat Prot Dosimetry; 2006; 119(1-4):454-7. PubMed ID: 16735565
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Fabrication of annealing equipment for optically stimulated luminescence (OSL) dosimeter].
    Nakagawa K; Hayashi H; Okino H; Takegami K; Okazaki T; Kobayashi I
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Oct; 70(10):1135-42. PubMed ID: 25327423
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.