166 related articles for article (PubMed ID: 8762974)
21. Flow injection analysis biosensor for urea analysis in adulterated milk using enzyme thermistor.
Mishra GK; Mishra RK; Bhand S
Biosens Bioelectron; 2010 Dec; 26(4):1560-4. PubMed ID: 20732804
[TBL] [Abstract][Full Text] [Related]
22. Urea potentiometric biosensor based on modified electrodes with urease immobilized on polyethylenimine films.
Lakard B; Herlem G; Lakard S; Antoniou A; Fahys B
Biosens Bioelectron; 2004 Jul; 19(12):1641-7. PubMed ID: 15142598
[TBL] [Abstract][Full Text] [Related]
23. Iridium oxide pH sensor for biomedical applications. Case urea-urease in real urine samples.
Prats-Alfonso E; Abad L; Casañ-Pastor N; Gonzalo-Ruiz J; Baldrich E
Biosens Bioelectron; 2013 Jan; 39(1):163-9. PubMed ID: 22857994
[TBL] [Abstract][Full Text] [Related]
24. An amperometric urea biosensor based on covalently immobilized urease on an electrode made of hyperbranched polyester functionalized gold nanoparticles.
Tiwari A; Aryal S; Pilla S; Gong S
Talanta; 2009 Jun; 78(4-5):1401-7. PubMed ID: 19362208
[TBL] [Abstract][Full Text] [Related]
25. Amperometric biosensor based on horseradish peroxidase for biogenic amine determinations in biological samples.
Castilho TJ; Sotomayor Mdel P; Kubota LT
J Pharm Biomed Anal; 2005 Apr; 37(4):785-91. PubMed ID: 15797802
[TBL] [Abstract][Full Text] [Related]
26. Enzyme-polyelectrolyte multilayer assemblies on reduced graphene oxide field-effect transistors for biosensing applications.
Piccinini E; Bliem C; Reiner-Rozman C; Battaglini F; Azzaroni O; Knoll W
Biosens Bioelectron; 2017 Jun; 92():661-667. PubMed ID: 27836616
[TBL] [Abstract][Full Text] [Related]
27. [A potentiometric sensor designed on the basis of urease immobilized in polyelectrolyte microcapsules].
Ternovskiĭ VI; Chernokhvostov IuV; Fomkina MG; Montrel' MM
Biofizika; 2007; 52(5):825-9. PubMed ID: 17969915
[TBL] [Abstract][Full Text] [Related]
28. Immobilization of bovine serum albumin as a sensitive biosensor for the detection of trace lead ion in solution by piezoelectric quartz crystal impedance.
Yin J; Wei W; Liu X; Kong B; Wu L; Gong S
Anal Biochem; 2007 Jan; 360(1):99-104. PubMed ID: 17097591
[TBL] [Abstract][Full Text] [Related]
29. Enzyme assays using sensor arrays based on ion-selective carbon nanotube field-effect transistors.
Melzer K; Bhatt VD; Jaworska E; Mittermeier R; Maksymiuk K; Michalska A; Lugli P
Biosens Bioelectron; 2016 Oct; 84():7-14. PubMed ID: 27140308
[TBL] [Abstract][Full Text] [Related]
30. Biosensors based on enzyme field-effect transistors for determination of some substrates and inhibitors.
Dzyadevych SV; Soldatkin AP; Korpan YI; Arkhypova VN; El'skaya AV; Chovelon JM; Martelet C; Jaffrezic-Renault N
Anal Bioanal Chem; 2003 Oct; 377(3):496-506. PubMed ID: 12904953
[TBL] [Abstract][Full Text] [Related]
31. Conductometric nitrate biosensor based on methyl viologen/Nafion/nitrate reductase interdigitated electrodes.
Xuejiang W; Dzyadevych SV; Chovelon JM; Renault NJ; Ling C; Siqing X; Jianfu Z
Talanta; 2006 Apr; 69(2):450-5. PubMed ID: 18970588
[TBL] [Abstract][Full Text] [Related]
32. Entrapment of live microbial cells in electropolymerized polyaniline and their use as urea biosensor.
Jha SK; Kanungo M; Nath A; D'Souza SF
Biosens Bioelectron; 2009 Apr; 24(8):2637-42. PubMed ID: 19230647
[TBL] [Abstract][Full Text] [Related]
33. A novel nitrite biosensor based on conductometric electrode modified with cytochrome c nitrite reductase composite membrane.
Zhang Z; Xia S; Leonard D; Jaffrezic-Renault N; Zhang J; Bessueille F; Goepfert Y; Wang X; Chen L; Zhu Z; Zhao J; Almeida MG; Silveira CM
Biosens Bioelectron; 2009 Feb; 24(6):1574-9. PubMed ID: 18804367
[TBL] [Abstract][Full Text] [Related]
34. [Enzyme biosensors for penicillin determination based on conductometric planar electrodes and pH-sensitive field effect transistor].
Arkhipova VN; Dziadevich SV; Soldatkin AP; El'skaia AV
Ukr Biokhim Zh (1978); 1996; 68(1):26-31. PubMed ID: 8755097
[TBL] [Abstract][Full Text] [Related]
35. Application of enzyme/zeolite sensor for urea analysis in serum.
Soldatkin OO; Kucherenko IS; Marchenko SV; Ozansoy Kasap B; Akata B; Soldatkin AP; Dzyadevych SV
Mater Sci Eng C Mater Biol Appl; 2014 Sep; 42():155-60. PubMed ID: 25063105
[TBL] [Abstract][Full Text] [Related]
36. A novel and sensitive resonance scattering assay for detection of urea in serum coupled urease catalytic reaction and NH4+ associated particle reaction.
Liang A; Qin H; Zhou L; Zhang Y; Ouyang H; Wang P; Jiang Z
Bioprocess Biosyst Eng; 2011 Jun; 34(5):639-45. PubMed ID: 21253771
[TBL] [Abstract][Full Text] [Related]
37. Determination of creatine in commercial creatine powder with new potentiometric and amperometric biosensors.
Karakuş E; Erden PE; Pekyardimci S; Kiliç E
Artif Cells Blood Substit Immobil Biotechnol; 2006; 34(3):337-47. PubMed ID: 16809134
[TBL] [Abstract][Full Text] [Related]
38. Influence of redox molecules on the electronic conductance of single-walled carbon nanotube field-effect transistors: application to chemical and biological sensing.
Boussaad S; Diner BA; Fan J
J Am Chem Soc; 2008 Mar; 130(12):3780-7. PubMed ID: 18321094
[TBL] [Abstract][Full Text] [Related]
39. Control of channel doping concentration for enhancing the sensitivity of 'top-down' fabricated Si nanochannel FET biosensors.
Park CW; Ahn CG; Yang JH; Baek IB; Ah CS; Kim A; Kim TY; Sung GY
Nanotechnology; 2009 Nov; 20(47):475501. PubMed ID: 19858563
[TBL] [Abstract][Full Text] [Related]
40. Liquid photopolymerizable compositions as immobilized matrix of biosensors.
Starodub NF; Rebriev AV
Bioelectrochemistry; 2007 Sep; 71(1):29-32. PubMed ID: 17383943
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]