These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
103 related articles for article (PubMed ID: 8763291)
1. The check X-ray: an unnecessary investigation after hip fracture fixation? Haddad FS; Williams RL; Prendergast CM Injury; 1996 Jun; 27(5):351-2. PubMed ID: 8763291 [TBL] [Abstract][Full Text] [Related]
2. Check radiography after fixation of hip fractures: is it necessary? Mohanty K; Gupta SK; Evans RM J R Coll Surg Edinb; 2000 Dec; 45(6):398-9. PubMed ID: 11153432 [TBL] [Abstract][Full Text] [Related]
3. Postoperative radiographs following hip fracture surgery. Do they influence patient management? Chakravarthy J; Mangat K; Qureshi A; Porter K Int J Clin Pract; 2007 Mar; 61(3):421-4. PubMed ID: 17313609 [TBL] [Abstract][Full Text] [Related]
4. Postoperative radiographs or thermal prints after internal fixation of fractures? A study of DHS fixation of hip fractures. Pattison RM; Calzada S; Koka SR; James SE Ann R Coll Surg Engl; 1996 Nov; 78(6):509-11. PubMed ID: 8943634 [TBL] [Abstract][Full Text] [Related]
5. Effects of three-dimensional navigation on intraoperative management and early postoperative outcome after open reduction and internal fixation of displaced acetabular fractures. Oberst M; Hauschild O; Konstantinidis L; Suedkamp NP; Schmal H J Trauma Acute Care Surg; 2012 Oct; 73(4):950-6. PubMed ID: 22710769 [TBL] [Abstract][Full Text] [Related]
6. [Complications of dynamic hip screw treatment for proximal femoral fractures]. Hrubina M; Skoták M; Běhounek J Acta Chir Orthop Traumatol Cech; 2010 Oct; 77(5):395-401. PubMed ID: 21040651 [TBL] [Abstract][Full Text] [Related]
7. Femoral neck fractures after removal of hardware in healed trochanteric fractures. Barquet A; Giannoudis PV; Gelink A Injury; 2017 Dec; 48(12):2619-2624. PubMed ID: 29223594 [TBL] [Abstract][Full Text] [Related]
8. Do check X-rays influence the management of patients who have undergone hip fracture fixation using image intensifier guidance? Khurana A Injury; 2007 Mar; 38(3):392. PubMed ID: 17292901 [No Abstract] [Full Text] [Related]
9. Routine radiography following ankle fracture fixation: a case for limiting its use. Harish S; Vince AS; Patel AD Injury; 1999 Dec; 30(10):699-701. PubMed ID: 10707246 [TBL] [Abstract][Full Text] [Related]
10. Reverse obliquity fractures of the intertrochanteric region of the femur. Haidukewych GJ; Israel TA; Berry DJ J Bone Joint Surg Am; 2001 May; 83(5):643-50. PubMed ID: 11379732 [TBL] [Abstract][Full Text] [Related]
11. Unstable intertrochanteric fractures of the hip. Caudle RJ; Hopson CN; Clarke RP Orthop Rev; 1987 Aug; 16(8):538-49. PubMed ID: 3331194 [TBL] [Abstract][Full Text] [Related]
12. Paper and dynamic hip screw surgery--a cheap and effective aid for hip fracture reduction. MacLean S; Dhillon S; Redfern D Acta Orthop Belg; 2011 Aug; 77(4):541-2. PubMed ID: 21954767 [TBL] [Abstract][Full Text] [Related]
13. Image intensifier as an aid to insertion of the Zickel nail apparatus for proximal femoral fractures. Forster IW; Lindsay JA Injury; 1979 Nov; 11(2):148-54. PubMed ID: 521153 [TBL] [Abstract][Full Text] [Related]
14. The stability of fixation of proximal femoral fractures: a radiostereometric analysis. van Embden D; Stollenwerck GA; Koster LA; Kaptein BL; Nelissen RG; Schipper IB Bone Joint J; 2015 Mar; 97-B(3):391-7. PubMed ID: 25737524 [TBL] [Abstract][Full Text] [Related]
15. Logistic regression analysis of risk factors for femoral head osteonecrosis after healed intertrochanteric fractures. Yin W; Xu Z; Sheng J; Zhang C; Zhu Z Hip Int; 2016 May; 26(3):215-9. PubMed ID: 27013487 [TBL] [Abstract][Full Text] [Related]
16. RAB-plate versus sliding hip screw for unstable trochanteric hip fractures: stability of the fixation and modes of failure--radiographic analysis of 218 fractures. Buciuto R; Hammer R J Trauma; 2001 Mar; 50(3):545-50. PubMed ID: 11265037 [TBL] [Abstract][Full Text] [Related]
17. Treatment of pertrochanteric fractures with a proximal femur locking compression plate. Zha GC; Chen ZL; Qi XB; Sun JY Injury; 2011 Nov; 42(11):1294-9. PubMed ID: 21356535 [TBL] [Abstract][Full Text] [Related]
18. [Osteosynthesis of proximal femoral fractures using short proximal femoral nails]. Pavelka T; Kortus J; Linhart M Acta Chir Orthop Traumatol Cech; 2003; 70(1):31-8. PubMed ID: 12764949 [TBL] [Abstract][Full Text] [Related]
19. Radiographic and functional results of osteosynthesis using the proximal femoral nail antirotation (PFNA) in the treatment of unstable intertrochanteric femoral fractures. Sahin S; Ertürer E; Oztürk I; Toker S; Seçkin F; Akman S Acta Orthop Traumatol Turc; 2010; 44(2):127-34. PubMed ID: 20676015 [TBL] [Abstract][Full Text] [Related]
20. Is distal screw entry point associated with subtrochanteric fracture after intracapsular hip fracture fixation? Hickey B; Jones HM; Jones S ANZ J Surg; 2014 Apr; 84(4):245-8. PubMed ID: 24812708 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]