These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 8773888)

  • 1. Healing of dentate or edentulous mandibular fractures treated with rigid or semirigid plate fixation--an experimental study in dogs.
    Freitag V; Landau H
    J Craniomaxillofac Surg; 1996 Apr; 24(2):83-7. PubMed ID: 8773888
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Ultrasound-aided resorbable osteosynthesis of fractures of the mandibular condylar base: an experimental study in sheep.
    Schneider M; Seinige C; Pilling E; Rasse M; Loukota R; Stadlinger B; Mai R; Eckelt U
    Br J Oral Maxillofac Surg; 2012 Sep; 50(6):528-32. PubMed ID: 22078939
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Miniplate osteosynthesis of fractures of the edentulous mandible.
    Mugino H; Takagi S; Oya R; Nakamura S; Ikemura K
    Clin Oral Investig; 2005 Dec; 9(4):266-70. PubMed ID: 16311742
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Osteosynthesis in facial bone fractures using miniplates: clinical and experimental studies.
    Ikemura K; Hidaka H; Etoh T; Kabata K
    J Oral Maxillofac Surg; 1988 Jan; 46(1):10-4. PubMed ID: 3422264
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of monocortical miniplates for the intraoral treatment of mandibular fractures.
    Chiodo TA; Milles M
    Atlas Oral Maxillofac Surg Clin North Am; 2009 Mar; 17(1):19-25. PubMed ID: 19237124
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of fracture healing and subimplant bone response following fixation with a locking miniplate and screw system for mandibular angle fractures in a sheep model.
    Poon CC; Verco S
    Int J Oral Maxillofac Surg; 2013 Jun; 42(6):736-45. PubMed ID: 23374732
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Bicortical extraoral plating of mandibular fractures.
    Gorzelnik L; Kozlovsky E
    Atlas Oral Maxillofac Surg Clin North Am; 2009 Mar; 17(1):35-43. PubMed ID: 19237126
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rigid internal fixation with titanium versus bioresorbable miniplates in the repair of mandibular fractures in rabbits.
    Hochuli-Vieira E; Cabrini Gabrielli MA; Pereira-Filho VA; Gabrielli MF; Padilha JG
    Int J Oral Maxillofac Surg; 2005 Mar; 34(2):167-73. PubMed ID: 15695046
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-dimensional v/s standard titanium miniplate fixation in the management of mandibular fractures--a randomized clinical study.
    Sehgal S; Ramanujam L; Prasad K; Krishnappa R
    J Craniomaxillofac Surg; 2014 Oct; 42(7):1292-9. PubMed ID: 24780350
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An in vitro study of the effect of bony buttressing on fixation strength of a fractured atrophic edentulous mandible model.
    Sikes JW; Smith BR; Mukherjee DP
    J Oral Maxillofac Surg; 2000 Jan; 58(1):56-61; discussion 62. PubMed ID: 10632166
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Results of treatment of fractures of the atrophic edentulous mandible by compression plating: a retrospective evaluation of 84 consecutive cases.
    Luhr HG; Reidick T; Merten HA
    J Oral Maxillofac Surg; 1996 Mar; 54(3):250-4; discussion 254-5. PubMed ID: 8600229
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Radiographic changes during bone healing after mandibular fractures.
    Kawai T; Murakami S; Hiranuma H; Sakuda M
    Br J Oral Maxillofac Surg; 1997 Oct; 35(5):312-8. PubMed ID: 9427438
    [TBL] [Abstract][Full Text] [Related]  

  • 13. AO compression plating technique for treating fractures of the edentulous mandible.
    Levine PA
    Otolaryngol Clin North Am; 1987 Aug; 20(3):457-77. PubMed ID: 3317201
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Histological findings in the alveolar sockets and tooth roots after experimental mandibular fractures in dogs.
    Freitag V; Landau H
    J Craniomaxillofac Surg; 1997 Aug; 25(4):203-11. PubMed ID: 9268899
    [No Abstract]   [Full Text] [Related]  

  • 15. Fracture line stability as a function of the internal fixation system: an in vitro comparison using a mandibular angle fracture model.
    Shetty V; McBrearty D; Fourney M; Caputo AA
    J Oral Maxillofac Surg; 1995 Jul; 53(7):791-801; discussion 801-2. PubMed ID: 7595794
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Histological study of fracture healing after compression plate osteosynthesis in dog mandibles].
    Hofmann H; Müller P; Heiner H; Thieme V
    Stomatol DDR; 1982 Aug; 32(8):567-73. PubMed ID: 6962558
    [No Abstract]   [Full Text] [Related]  

  • 17. [Experimental studies of the biomechanical stability of different miniplate configurations for the mandibular angle].
    Schierle HP; Schmelzeisen R; Rahn B
    Fortschr Kiefer Gesichtschir; 1996; 41():166-70. PubMed ID: 8755434
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of compression and strength of divergent screws mounted on miniplates for fixation of mandibular fractures: an in vitro experimental study.
    Jafarian M; Pourdanesh F; Esmaeelinejad M; Dehghani N; Aghdashi F; Tabrizi R
    Br J Oral Maxillofac Surg; 2015 Sep; 53(7):613-7. PubMed ID: 25921364
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Repair of mandibular fractures using the 2.0 mm system. A review.
    Klotch DW; Gal RL
    J Craniomaxillofac Trauma; 1995; 1(1):38-42. PubMed ID: 11951441
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Fractures of the edentulous atrophic mandible. Fracture management and complications].
    Kunz C; Hammer B; Prein J
    Mund Kiefer Gesichtschir; 2001 Jul; 5(4):227-32. PubMed ID: 11550605
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.