These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
9. Successful implantation of cardioverter-defibrillator systems in patients with elevated defibrillation thresholds. Brooks R; Torchiana D; Vlahakes GJ; Ruskin JN; McGovern BA; Garan H J Am Coll Cardiol; 1993 Aug; 22(2):569-74. PubMed ID: 8335831 [TBL] [Abstract][Full Text] [Related]
10. Internal defibrillation with minimal skeletal muscle activation: a new paradigm toward painless defibrillation. Jayam V; Zviman M; Jayanti V; Roguin A; Halperin H; Berger RD Heart Rhythm; 2005 Oct; 2(10):1108-13. PubMed ID: 16188591 [TBL] [Abstract][Full Text] [Related]
11. Multicenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic ventricular defibrillation. Transthoracic Investigators. Bardy GH; Marchlinski FE; Sharma AD; Worley SJ; Luceri RM; Yee R; Halperin BD; Fellows CL; Ahern TS; Chilson DA; Packer DL; Wilber DJ; Mattioni TA; Reddy R; Kronmal RA; Lazzara R Circulation; 1996 Nov; 94(10):2507-14. PubMed ID: 8921795 [TBL] [Abstract][Full Text] [Related]
12. Emergency intracardiac defibrillation for refractory ventricular fibrillation during routine electrophysiologic study. Cohen TJ; Scheinman MM; Pullen BT; Chiesa NA; Gonzalez R; Herre JM; Griffin JC J Am Coll Cardiol; 1991 Nov; 18(5):1280-4. PubMed ID: 1918705 [TBL] [Abstract][Full Text] [Related]
13. Intracardiac emergency defibrillation for refractory ventricular fibrillation during implantation of cardioverter defibrillators with nonthoracotomy lead systems. Pitschner HF; Neuzner J Pacing Clin Electrophysiol; 1993 Feb; 16(2):291-6. PubMed ID: 8446519 [TBL] [Abstract][Full Text] [Related]
14. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697 [TBL] [Abstract][Full Text] [Related]
15. A direct comparison of epicardial and nonthoracotomy defibrillation using monophasic and biphasic shocks. Thakur RK; Souza JJ; Troup PJ; Chapman PD; Wetherbee JN Pacing Clin Electrophysiol; 1995 Jan; 18(1 Pt 1):70-4. PubMed ID: 7700834 [TBL] [Abstract][Full Text] [Related]
16. An appropriate defibrillation threshold obtained by the combined connection between two shock leads and ICD generator. Sato A; Chinushi M; Iijima K; Watanabe H; Izumi D; Furushima H; Sonoda K; Hasegawa K; Yagihara N; Aizawa Y Intern Med; 2011; 50(22):2815-8. PubMed ID: 22082895 [TBL] [Abstract][Full Text] [Related]
17. Use of multiple patches during implantation of epicardial defibrillator systems. Baerman JM; Blakeman BP; Olshansky B; Kopp DE; Kall JG; Wilber DJ Am J Cardiol; 1993 Jan; 71(1):68-71. PubMed ID: 8420238 [TBL] [Abstract][Full Text] [Related]
18. Transthoracic defibrillation of short-lasting ventricular fibrillation: a randomised trial for comparison of the efficacy of low-energy biphasic rectilinear and monophasic damped sine shocks. Szili-Torok T; Theuns D; Verblaauw T; Scholten M; Kimman GJ; Res J; Jordaens L Acta Cardiol; 2002 Oct; 57(5):329-34. PubMed ID: 12405569 [TBL] [Abstract][Full Text] [Related]