BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 8776198)

  • 1. Nitrous oxide control in the dental operatory: auxiliary exhaust and mask leakage, design, and scavenging flow rate as factors.
    Crouch KG; Johnston OE
    Am Ind Hyg Assoc J; 1996 Mar; 57(3):272-8. PubMed ID: 8776198
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a modified scavenging system to reduce occupational exposure to nitrous oxide in labor and delivery rooms.
    Chessor E; Verhoeven M; Hon CY; Teschke K
    J Occup Environ Hyg; 2005 Jun; 2(6):314-22. PubMed ID: 16020092
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Control of nitrous oxide exposures in dental operatories using local exhaust ventilation: a pilot study.
    Jacobs DE; Middendorf PJ
    Anesth Prog; 1986; 33(5):235-42. PubMed ID: 3465259
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Nitrous oxide scavenging in dental surgery. II. An evaluation of a local exhaust system.
    Hallonsten AL
    Swed Dent J; 1982; 6(5):215-23. PubMed ID: 6960505
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Occupational exposure to nitrous oxide in dental operatories.
    Middendorf PJ; Jacobs DE; Smith KA; Mastro DM
    Anesth Prog; 1986; 33(2):91-7. PubMed ID: 3459383
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Effectiveness of anesthetic gas scavengers fulfilling EN 740 requirements with reference to equipment leakage and fresh gas flow].
    Marx T; Fröba G; Zwing M; Knobloch V; Georgieff M
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Feb; 32(2):101-4. PubMed ID: 9172712
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Operatory ventilation and scavenger evacuation rate influence on ambient nitrous oxide levels.
    Borganelli GN; Primosch RE; Henry RJ
    J Dent Res; 1993 Sep; 72(9):1275-8. PubMed ID: 8360375
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effectiveness of 2 scavenger mask systems for reducing exposure to nitrous oxide in a hospital-based pediatric dental clinic: a pilot study.
    Freilich MM; Alexander L; Sándor GK; Judd P
    J Can Dent Assoc; 2007 Sep; 73(7):615. PubMed ID: 17868510
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Occupational exposure to nitrous oxide - the role of scavenging and ventilation systems in reducing the exposure level in operating rooms.
    Krajewski W; Kucharska M; Wesolowski W; Stetkiewicz J; Wronska-Nofer T
    Int J Hyg Environ Health; 2007 Mar; 210(2):133-8. PubMed ID: 17045524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Exposure control practices for administering nitrous oxide: A survey of dentists, dental hygienists, and dental assistants.
    Boiano JM; Steege AL; Sweeney MH
    J Occup Environ Hyg; 2017 Jun; 14(6):409-416. PubMed ID: 27937086
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A long-term study of the development of N2O controls at a pediatric dental facility.
    Crouch KG; McGlothlin JD; Johnston OE
    AIHAJ; 2000; 61(5):753-6. PubMed ID: 11071429
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical evaluation of the efficacy of three nitrous oxide scavenging units during dental treatment.
    Certosimo F; Walton M; Hartzell D; Farris J
    Gen Dent; 2002; 50(5):430-5. PubMed ID: 12448895
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The effects of various dental procedures and patient behaviors upon nitrous oxide scavenger effectiveness.
    Henry RJ; Primosch RE; Courts FJ
    Pediatr Dent; 1992; 14(1):19-25. PubMed ID: 1502110
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Exposure to anesthetic gases].
    Aasmoe L; Olsen OH
    Tidsskr Nor Laegeforen; 1995 Sep; 115(21):2652-5. PubMed ID: 7570476
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Nitrous oxide scavenging in dental surgery. I. A comparison of the efficiency of different scavenging devices.
    Hallonsten AL
    Swed Dent J; 1982; 6(5):203-13. PubMed ID: 6217569
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-volume aspiration as a supplemental scavenging method for reducing ambient nitrous oxide levels in the operatory: a laboratory study.
    Henry RJ; Borganelli GN
    Int J Paediatr Dent; 1995 Sep; 5(3):157-61. PubMed ID: 9601236
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of the effectiveness of nitrous oxide scavenging devices.
    Donaldson D; Orr J
    J Can Dent Assoc; 1989 Jul; 55(7):535-7. PubMed ID: 2667719
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thermocamera studies of nitrous oxide dispersion in the dental surgery.
    Carlsson P; Hallén B; Hallonsten AL; Ljungqvist B
    Scand J Dent Res; 1983 Jun; 91(3):224-30. PubMed ID: 6576462
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Devices for the reduction of N2O pollution during conscious sedation in dentistry].
    Virgili A; Scapellato ML; Maccà I; Perini M; Moretto J; Carrieri M; Gori G; Manani G; Varotto E; Bartolucci GB
    G Ital Med Lav Ergon; 2003; 25 Suppl(3):85-6. PubMed ID: 14979096
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Control of occupational exposure to nitrous oxide in the oral surgery office.
    Whitcher C; Zimmerman DC; Piziali RL
    J Oral Surg; 1978 Jun; 36(6):431-40. PubMed ID: 274530
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.