These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 8777408)

  • 1. [Reliability of pressure measures determined with probes used for establishing the urethral pressure profile by the perfusion method].
    Le Normand L; Glemain P; Cordonnier JP; Wetzel O; Bochereau G; Buzelin JM
    Prog Urol; 1995 Dec; 5(6):980-4. PubMed ID: 8777408
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparative study of water perfusion catheters and microtip transducer catheters for urethral pressure measurements.
    Kuhn A; Nager CW; Hawkins E; Schulz J; Stanton SL
    Int Urogynecol J Pelvic Floor Dysfunct; 2007 Aug; 18(8):931-5. PubMed ID: 17131168
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Safer urethral catheters: how study of catheter balloon pressure and force can guide design.
    Wu AK; Blaschko SD; Garcia M; McAninch JW; Aaronson DS
    BJU Int; 2012 Apr; 109(7):1110-4. PubMed ID: 21871052
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Static single channel and multichannel water perfusion pressure profilometry in a bench model of a urethra.
    Hirst GR; Beeton RJ; Lucas MG
    Neurourol Urodyn; 2010 Sep; 29(7):1312-9. PubMed ID: 20127829
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Recommendations for the urodynamic examination in the investigation of non-neurological female urinary incontinence].
    Hermieu JF;
    Prog Urol; 2007 Nov; 17(6 Suppl 2):1264-84. PubMed ID: 18214138
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Air charged and microtip catheters cannot be used interchangeably for urethral pressure measurement: a prospective, single-blind, randomized trial.
    Zehnder P; Roth B; Burkhard FC; Kessler TM
    J Urol; 2008 Sep; 180(3):1013-7. PubMed ID: 18639301
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Catheter measurements of the urethral pressure].
    Bykova AA; Regirer SA
    Biofizika; 2004; 49(6):1134-8. PubMed ID: 15612559
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical features of the system used to perform multichannel urethral pressure profilometry.
    Messelink EJ; Dobbe I; Kools C; Dabhoiwala NF; Dijkhuizen T; Schneider P; Lettinga KP; Kurth K
    Tech Urol; 1997; 3(3):158-63. PubMed ID: 9422448
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Types of urethral catheters for management of short-term voiding problems in hospitalized adults: a short version Cochrane review.
    Schumm K; Lam TB
    Neurourol Urodyn; 2008; 27(8):738-46. PubMed ID: 18951451
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reexamination of the intraurethral pressure determination using CO2 perfusion: its monitoring mechanism, standardization, and employment for the determination of the urethral constitutive property.
    Ghista DN; Perkash I
    Prog Clin Biol Res; 1981; 78():243-51. PubMed ID: 6801704
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Simultaneous diuresis cysto-urethrometry and multichannel urethral pressure profilometry in continent female dogs.
    Nickel RF; van den Brom WE
    Am J Vet Res; 1996 Aug; 57(8):1131-6. PubMed ID: 8836362
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Urethral pressure profile in children: a comparison between perfused catheters and micro-transducers, and a study of the usefulness of urethral pressure profile measurements in children.
    Meunier P; Mollard P
    J Urol; 1978 Aug; 120(2):207-10. PubMed ID: 671637
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of air-charged and water-filled urodynamic pressure measurement catheters.
    Cooper MA; Fletter PC; Zaszczurynski PJ; Damaser MS
    Neurourol Urodyn; 2011 Mar; 30(3):329-34. PubMed ID: 21305591
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Urethral pressure profilometry with membrane catheter compared with perfusion catheter systems.
    Schmidt RA; Witherow R; van Gool JD; Tanagho EA
    Urol Int; 1978; 33(5):345-54. PubMed ID: 705985
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Accuracy of pressure measurements obtained with a new rectal balloon catheter].
    Le Normand L; Glemain P; Cordonnier JP; Brunel P; Karam G; Boullanger P; Buzelin JM
    Prog Urol; 2001 Feb; 11(1):127-31. PubMed ID: 11296633
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Three dimensional urethral pressure profile. II. Basic consideration of the catheter with only one eye and comparison with the catheter with the tip transducer by Millar].
    Morita T; Nishimoto T; Noto H
    Nihon Hinyokika Gakkai Zasshi; 1983 Oct; 74(10):1772-7. PubMed ID: 6676557
    [No Abstract]   [Full Text] [Related]  

  • 17. Comparison of alpha 1-adrenoceptor agonists in canine urethral pressure profilometry and abdominal leak point pressure models.
    Brune ME; O'Neill AB; Gauvin DM; Katwala SP; Altenbach RJ; Brioni JD; Hancock AA; Sullivan JP
    J Urol; 2001 Oct; 166(4):1555-9. PubMed ID: 11547130
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prospective trial comparing solid-state catheter and water-perfusion triple-lumen catheter for sphincter of Oddi manometry done at the time of ERCP.
    Draganov PV; Kowalczyk L; Forsmark CE
    Gastrointest Endosc; 2009 Jul; 70(1):92-5. PubMed ID: 19386306
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hydrophilic-coated catheters for intermittent catheterisation reduce urethral micro trauma: a prospective, randomised, participant-blinded, crossover study of three different types of catheters.
    Stensballe J; Looms D; Nielsen PN; Tvede M
    Eur Urol; 2005 Dec; 48(6):978-83. PubMed ID: 16126331
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Membrane catheter: effective for recording pressure in lower urinary tract.
    Tanagho EA; Jonas U
    Urology; 1977 Aug; 10(2):173-6. PubMed ID: 561471
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.