BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 8779023)

  • 1. Spinal cord and nerve root monitoring in spine surgery and related procedures.
    Herdmann J; Deletis V; Edmonds HL; Morota N
    Spine (Phila Pa 1976); 1996 Apr; 21(7):879-85. PubMed ID: 8779023
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intraoperative neurophysiology of the conus medullaris and cauda equina.
    Kothbauer KF; Deletis V
    Childs Nerv Syst; 2010 Feb; 26(2):247-53. PubMed ID: 19904544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Intraoperative neurophysiological monitoring in pediatric neurosurgery: why, when, how?
    Sala F; Krzan MJ; Deletis V
    Childs Nerv Syst; 2002 Jul; 18(6-7):264-87. PubMed ID: 12172930
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Monitoring.
    Leppanen RE
    J Clin Monit Comput; 2005 Dec; 19(6):437-61. PubMed ID: 16437295
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intraoperative neurophysiologic detection of iatrogenic C5 nerve root injury during laminectomy for cervical compression myelopathy.
    Fan D; Schwartz DM; Vaccaro AR; Hilibrand AS; Albert TJ
    Spine (Phila Pa 1976); 2002 Nov; 27(22):2499-502. PubMed ID: 12435981
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Monitoring the neurogenic mixed evoked potentials during surgery of the spine: a good solution?].
    Péréon Y; Nguyen The Tich S
    Neurophysiol Clin; 1998 Sep; 28(4):321-34. PubMed ID: 9793064
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Intraoperative neurophysiological monitoring of the spinal cord during spinal cord and spine surgery: a review focus on the corticospinal tracts.
    Deletis V; Sala F
    Clin Neurophysiol; 2008 Feb; 119(2):248-64. PubMed ID: 18053764
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intraoperative monitoring for tethered cord surgery: an update.
    Kothbauer KF; Novak K
    Neurosurg Focus; 2004 Feb; 16(2):E8. PubMed ID: 15209491
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Intraoperative spinal cord and nerve root monitoring: a survey of Canadian spine surgeons.
    Peeling L; Hentschel S; Fox R; Hall H; Fourney DR
    Can J Surg; 2010 Oct; 53(5):324-8. PubMed ID: 20858377
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intraoperative electrophysiologic monitoring: considerations for complex spinal surgery.
    Padberg AM; Thuet ED
    Neurosurg Clin N Am; 2006 Jul; 17(3):205-26, v. PubMed ID: 16876023
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Influence of hypotension and nerve root section on the ability to mobilize the spinal cord during spine surgery. An experimental study in a pig model.
    Barrios C; Pizá-Vallespir G; Burgos J; De Blas G; Montes E; Hevia E; Collazos-Castro JE; Correa C
    Spine J; 2014 Jul; 14(7):1300-7. PubMed ID: 24333455
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Intraoperative monitoring of nerve roots in spinal surgery].
    Cortés V
    Rev Neurol; 2004 Jan 1-15; 38(1):75-8. PubMed ID: 14730497
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Failure of Intraoperative Monitoring to Detect Postoperative Neurologic Deficits: A 25-year Experience in 12,375 Spinal Surgeries.
    Raynor BL; Padberg AM; Lenke LG; Bridwell KH; Riew KD; Buchowski JM; Luhmann SJ
    Spine (Phila Pa 1976); 2016 Sep; 41(17):1387-1393. PubMed ID: 26913466
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intraoperative Spinal Cord and Nerve Root Monitoring: A Hospital Survey and Review.
    Rattenni RN; Cheriyan T; Lee A; Bendo JA; Errico TJ; Goldstein JE
    Bull Hosp Jt Dis (2013); 2015 Mar; 73(1):25-36. PubMed ID: 26516998
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The diagnostic value of multimodal intraoperative monitoring (MIOM) during spine surgery: a prospective study of 1,017 patients.
    Sutter M; Eggspuehler A; Grob D; Jeszenszky D; Benini A; Porchet F; Mueller A; Dvorak J
    Eur Spine J; 2007 Nov; 16 Suppl 2(Suppl 2):S162-70. PubMed ID: 17665225
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Re. Transcranial motor-evoked potentials combined with response recording through compound muscle action potentials as the sole modality of spinal cord monitoring in spinal deformity surgery. Hsu, Cree, Lagopolous and Cummine. Spine. 33(10). 1100-1106.
    Norton JA
    Spine (Phila Pa 1976); 2008 Nov; 33(23):2576. PubMed ID: 18978598
    [No Abstract]   [Full Text] [Related]  

  • 17. Combined spinal cord monitoring using neurogenic mixed evoked potentials and collision techniques.
    Péréon Y; Nguyen The Tich S; Delécrin J; Pham Dang C; Bodin J; Drouet JC; Passuti N
    Spine (Phila Pa 1976); 2002 Jul; 27(14):1571-6. PubMed ID: 12131720
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spinal cord and nerve root monitoring during surgical treatment of lumbar stenosis.
    Weiss DS
    Clin Orthop Relat Res; 2001 Mar; (384):82-100. PubMed ID: 11249183
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intraoperative neurophysiology of the conus medullaris and cauda equina.
    Pang D
    Childs Nerv Syst; 2010 Apr; 26(4):411-2. PubMed ID: 20191273
    [No Abstract]   [Full Text] [Related]  

  • 20. Intraoperative motor and sensory monitoring of the cauda equina.
    Kothbauer K; Schmid UD; Seiler RW; Eisner W
    Neurosurgery; 1994 Apr; 34(4):702-7; discussion 707. PubMed ID: 8008170
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.