These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 8779440)
41. Simultaneous determination of methamphetamine and its metabolite, amphetamine, in urine using a high performance liquid chromatography column-switching method. Kumihashi M; Ameno K; Shibayama T; Suga K; Miyauchi H; Jamal M; Wang W; Uekita I; Ijiri I J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jan; 845(1):180-3. PubMed ID: 16916628 [TBL] [Abstract][Full Text] [Related]
42. Solvent-enhanced microwave-assisted derivatization following solid-phase extraction combined with gas chromatography-mass spectrometry for determination of amphetamines in urine. Chung LW; Liu GJ; Li ZG; Chang YZ; Lee MR J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Oct; 874(1-2):115-8. PubMed ID: 18815079 [TBL] [Abstract][Full Text] [Related]
43. Simple and sensitive high-performance liquid chromatographic determination of methamphetamines in human urine as derivatives of 4-(4,5-diphenyl-1H-imidazol-2-yl) benzoyl chloride, a new fluorescence derivatization reagent. Al-Dirbashi O; Qvarnstrom J; Irgum K; Nakashima K J Chromatogr B Biomed Sci Appl; 1998 Aug; 712(1-2):105-12. PubMed ID: 9698233 [TBL] [Abstract][Full Text] [Related]
44. Chiral separation and quantification of R/S-amphetamine, R/S-methamphetamine, R/S-MDA, R/S-MDMA, and R/S-MDEA in whole blood by GC-EI-MS. Rasmussen LB; Olsen KH; Johansen SS J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Oct; 842(2):136-41. PubMed ID: 16797258 [TBL] [Abstract][Full Text] [Related]
45. Analysis of Methamphetamine in Urine by HPLC with Solid-Phase Dispersive Extraction and Solid-Phase Fluorescence Derivatization. Saito K; Takase M; Yasumura Y; Ito R Chem Pharm Bull (Tokyo); 2023; 71(1):24-30. PubMed ID: 36596509 [TBL] [Abstract][Full Text] [Related]
46. Screening of amphetamines by gradient microbore liquid chromatography and pre-column technology. Slais K; Nielen MW; Brinkman UA; Frei RW J Chromatogr; 1987 Apr; 393(1):57-68. PubMed ID: 3597599 [TBL] [Abstract][Full Text] [Related]
47. Rapid determination of p-hydroxylated methamphetamine metabolites by column liquid chromatography-electrochemistry. Shimosato K; Tomita M; Ijiri I J Chromatogr; 1986 Apr; 377():279-86. PubMed ID: 3711218 [TBL] [Abstract][Full Text] [Related]
48. Polymeric activated ester reagents for off-line and on-line derivatizations of amine nucleophiles in high-performance liquid chromatography with ultraviolet and fluorescence detection. Gao CX; Chou TY; Krull IS Anal Chem; 1989 Jul; 61(14):1538-48. PubMed ID: 2757212 [TBL] [Abstract][Full Text] [Related]
49. Determination of methamphetamine, amphetamine and piperidine in human urine by high-performance liquid chromatography with chemiluminescence detection. Hayakawa K; Imaizumi N; Ishikura H; Minogawa E; Takayama N; Kobayashi H; Miyazaki M J Chromatogr; 1990 Aug; 515():459-66. PubMed ID: 2283372 [TBL] [Abstract][Full Text] [Related]
50. Rapid determination of methotrexate in plasma by high-performance liquid chromatography with on-line solid-phase extraction and automated precolumn derivatization. Emara S; Askal H; Masujima T Biomed Chromatogr; 1998; 12(6):338-42. PubMed ID: 9861494 [TBL] [Abstract][Full Text] [Related]
51. Development of a two-step injector for GC-MS with on-column derivatization, and its application to the determination of amphetamine-type stimulants (ATS) in biological specimens. Miki A; Katagi M; Zaitsu K; Nishioka H; Tsuchihashi H J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Apr; 865(1-2):25-32. PubMed ID: 18342584 [TBL] [Abstract][Full Text] [Related]
52. Quantitative and isomeric determination of amphetamine and methamphetamine from urine using a nonprotic elution solvent and R(-)-alpha-methoxy-alpha-trifluoromethylphenylacetic acid chloride derivatization. Holler JM; Vorce SP; Bosy TZ; Jacobs A J Anal Toxicol; 2005 Oct; 29(7):652-7. PubMed ID: 16419395 [TBL] [Abstract][Full Text] [Related]
53. Phentermine interference and high L-methamphetamine concentration problems in GC-EI-MS SIM Analyses of R-(-)-α-methoxy-α-(trifluoromethyl)phenylacetyl chloride-derivatized amphetamines and methamphetamines†. Hamilton TJ; Qui HZ; Dozier KV; Fuller ZJ J Anal Toxicol; 2014 Sep; 38(7):456-61. PubMed ID: 24951536 [TBL] [Abstract][Full Text] [Related]
54. Simultaneous determination of amphetamines and amphetamine-derived designer drugs in human urine by GC-MS. Maresová V; Chadt J; Prikryl L Neuro Endocrinol Lett; 2006 Dec; 27 Suppl 2():121-4. PubMed ID: 17159795 [TBL] [Abstract][Full Text] [Related]
55. Rapid extraction and determination of amphetamines in human urine samples using dispersive liquid-liquid microextraction and solidification of floating organic drop followed by high performance liquid chromatography. Ahmadi-Jouibari T; Fattahi N; Shamsipur M J Pharm Biomed Anal; 2014 Jun; 94():145-51. PubMed ID: 24583909 [TBL] [Abstract][Full Text] [Related]
56. Measurement uncertainty for the determination of amphetamines in urine by liquid-phase microextraction and gas chromatography-mass spectrometry. Franco de Oliveira SC; Yonamine M Forensic Sci Int; 2016 Aug; 265():81-8. PubMed ID: 26836147 [TBL] [Abstract][Full Text] [Related]
57. [The urinary screening and identification of amphetamines in clinical toxicology laboratory--VGH]. Lin WL; Deng JF; Chou LJ; Hung DZ; Tsai WJ Zhonghua Yi Xue Za Zhi (Taipei); 1991 Oct; 48(4):305-9. PubMed ID: 1659927 [TBL] [Abstract][Full Text] [Related]
58. Gas chromatography/mass spectrometry determination of amphetamine-related drugs and ephedrines in plasma, urine and hair samples after derivatization with 2,2,2-trichloroethyl chloroformate. Frison G; Tedeschi L; Favretto D; Reheman A; Ferrara SD Rapid Commun Mass Spectrom; 2005; 19(7):919-27. PubMed ID: 15747332 [TBL] [Abstract][Full Text] [Related]
59. Determination of amphetamine-related compounds by high-performance liquid chromatography with chemiluminescence and fluorescence detections. Hayakawa K; Hasegawa K; Imaizumi N; Wong OS; Miyazaki M J Chromatogr; 1989 Mar; 464(2):343-52. PubMed ID: 2722984 [TBL] [Abstract][Full Text] [Related]
60. An evaluation of solid phase microextraction for aliphatic amines using derivatization with 9-fluorenylmethyl chloroformate and liquid chromatography. Herráez-Hernández R; Cháfer-Pericás C; Verdú-Andrés J; Campíns-Falcó P J Chromatogr A; 2006 Feb; 1104(1-2):40-6. PubMed ID: 16375912 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]