These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 8779446)

  • 1. Postelectrophoresis capillary scanning method for DNA sequencing.
    Kim S; Yoo HJ; Hahn JH
    Anal Chem; 1996 Mar; 68(5):936-9. PubMed ID: 8779446
    [TBL] [Abstract][Full Text] [Related]  

  • 2. On-line nanoliter cycle sequencing reaction with capillary zone electrophoresis purification for DNA sequencing.
    Xue G; Pang HM; Yeung ES
    J Chromatogr A; 2001 Apr; 914(1-2):245-56. PubMed ID: 11358219
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Ultra-high-speed DNA sequencing using capillary electrophoresis chips.
    Woolley AT; Mathies RA
    Anal Chem; 1995 Oct; 67(20):3676-80. PubMed ID: 8644919
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated one-step DNA sequencing based on nanoliter reaction volumes and capillary electrophoresis.
    Pang HM; Yeung ES
    Nucleic Acids Res; 2000 Aug; 28(15):E73. PubMed ID: 10908366
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Side-entry excitation and detection of square capillary array electrophoresis for DNA sequencing.
    Lu SX; Yeung ES
    J Chromatogr A; 1999 Aug; 853(1-2):359-69. PubMed ID: 10486743
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of non-cross-linked polyacrylamide for four-color DNA sequencing by capillary electrophoresis separation of fragments up to 640 bases in length in two hours.
    Zhang J; Fang Y; Hou JY; Ren HJ; Jiang R; Roos P; Dovichi NJ
    Anal Chem; 1995 Dec; 67(24):4589-93. PubMed ID: 8633791
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The use of elevated column temperature to extend DNA sequencing read lengths in capillary electrophoresis with replaceable polymer matrices.
    Klepárnik K; Foret F; Berka J; Goetzinger W; Miller AW; Karger BL
    Electrophoresis; 1996 Dec; 17(12):1860-6. PubMed ID: 9034767
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sequencing using capillary electrophoresis of short tandem repeat alleles separated and purified by high performance liquid chromatography.
    Marino MA; Devaney JM; Smith JK; Girard JE
    Electrophoresis; 1998 Jan; 19(1):108-18. PubMed ID: 9511871
    [TBL] [Abstract][Full Text] [Related]  

  • 9. RIKEN integrated sequence analysis (RISA) system--384-format sequencing pipeline with 384 multicapillary sequencer.
    Shibata K; Itoh M; Aizawa K; Nagaoka S; Sasaki N; Carninci P; Konno H; Akiyama J; Nishi K; Kitsunai T; Tashiro H; Itoh M; Sumi N; Ishii Y; Nakamura S; Hazama M; Nishine T; Harada A; Yamamoto R; Matsumoto H; Sakaguchi S; Ikegami T; Kashiwagi K; Fujiwake S; Inoue K; Togawa Y
    Genome Res; 2000 Nov; 10(11):1757-71. PubMed ID: 11076861
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A sample purification method for rugged and high-performance DNA sequencing by capillary electrophoresis using replaceable polymer solutions. A. Development of the cleanup protocol.
    Ruiz-Martinez MC; Salas-Solano O; Carrilho E; Kotler L; Karger BL
    Anal Chem; 1998 Apr; 70(8):1516-27. PubMed ID: 9569761
    [TBL] [Abstract][Full Text] [Related]  

  • 11. DNA sequencing using capillary array electrophoresis.
    Huang XC; Quesada MA; Mathies RA
    Anal Chem; 1992 Sep; 64(18):2149-54. PubMed ID: 1416049
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Poly-N-hydroxyethylacrylamide (polyDuramide): a novel, hydrophilic, self-coating polymer matrix for DNA sequencing by capillary electrophoresis.
    Albarghouthi MN; Buchholz BA; Huiberts PJ; Stein TM; Barron AE
    Electrophoresis; 2002 May; 23(10):1429-40. PubMed ID: 12116153
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Separation of 4-color DNA sequencing extension products in noncovalently coated capillaries using low viscosity polymer solutions.
    Madabhushi RS
    Electrophoresis; 1998 Feb; 19(2):224-30. PubMed ID: 9548284
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Star-shaped polymers for DNA sequencing by capillary electrophoresis.
    Gao F; Tie C; Zhang XX; Niu Z; He X; Ma Y
    J Chromatogr A; 2011 May; 1218(20):3037-41. PubMed ID: 21481881
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ultra-high throughput rotary capillary array electrophoresis scanner for fluorescent DNA sequencing and analysis.
    Scherer JR; Kheterpal I; Radhakrishnan A; Ja WW; Mathies RA
    Electrophoresis; 1999 Jun; 20(7):1508-17. PubMed ID: 10424474
    [TBL] [Abstract][Full Text] [Related]  

  • 16. DNA sequencing using 96-capillary array electrophoresis.
    Pang H; Pavski V; Yeung ES
    J Biochem Biophys Methods; 1999 Nov; 41(2-3):121-32. PubMed ID: 10626770
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Integrated electroosmotically-driven on-line sample purification system for nanoliter DNA sequencing by capillary electrophoresis.
    He Y; Pang HM; Yeung ES
    J Chromatogr A; 2000 Oct; 894(1-2):179-90. PubMed ID: 11100861
    [TBL] [Abstract][Full Text] [Related]  

  • 18. DNA sequencing using a four-color confocal fluorescence capillary array scanner.
    Kheterpal I; Scherer JR; Clark SM; Radhakrishnan A; Ju J; Ginther CL; Sensabaugh GF; Mathies RA
    Electrophoresis; 1996 Dec; 17(12):1852-9. PubMed ID: 9034766
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-speed DNA sequencing by tube-based capillary electrophoresis.
    Sakai T; Sonehara T; Goda C; Kohara Y; Anazawa T
    Electrophoresis; 2004 Oct; 25(20):3378-86. PubMed ID: 15490443
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Capillary array electrophoresis and high-throughput DNA sequencing].
    Zhen ZC; Yao ZJ
    Se Pu; 2001 Jul; 19(4):361-4. PubMed ID: 12545503
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.