These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 8779493)

  • 1. Silicone breast implant bleed and rupture: clinical diagnosis and predictive value of mammography and ultrasound.
    Beekman WH; Scot MG; Taets van Amerongen AH; Hage JJ; Mulder JW
    Ann Plast Surg; 1996 Apr; 36(4):345-7. PubMed ID: 8779493
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Imaging spectrum of breast implant complications: mammography, ultrasound, and magnetic resonance imaging.
    O'Toole M; Caskey CI
    Semin Ultrasound CT MR; 2000 Oct; 21(5):351-61. PubMed ID: 11071616
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Multimodality Imaging-based Evaluation of Single-Lumen Silicone Breast Implants for Rupture.
    Seiler SJ; Sharma PB; Hayes JC; Ganti R; Mootz AR; Eads ED; Teotia SS; Evans WP
    Radiographics; 2017; 37(2):366-382. PubMed ID: 28186859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rupture of silicone-gel breast implants: causes, sequelae, and diagnosis.
    Brown SL; Silverman BG; Berg WA
    Lancet; 1997 Nov; 350(9090):1531-7. PubMed ID: 9388410
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Silicone breast implant rupture: pitfalls of magnetic resonance imaging and relative efficacies of magnetic resonance, mammography, and ultrasound.
    Ikeda DM; Borofsky HB; Herfkens RJ; Sawyer-Glover AM; Birdwell RL; Glover GH
    Plast Reconstr Surg; 1999 Dec; 104(7):2054-62. PubMed ID: 11149768
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnosis of silicone gel breast implant rupture by ultrasonography.
    Chung KC; Wilkins EG; Beil RJ; Helvie MA; Ikeda DM; Oneal RM; Forrest ME; Smith DJ
    Plast Reconstr Surg; 1996 Jan; 97(1):104-9. PubMed ID: 8532766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Efficacy of ultrasound, mammography and magnetic resonance imaging in detecting breast implant rupture: A retrospective study of 175 reconstructive and aesthetic sub-pectoral breast augmentation cases.
    Stivala A; Rem K; Leuzzi S; Moris V; François C; Revol M; Cristofari S
    J Plast Reconstr Aesthet Surg; 2017 Nov; 70(11):1520-1526. PubMed ID: 28739171
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The life span of silicone gel breast implants and a comparison of mammography, ultrasonography, and magnetic resonance imaging in detecting implant rupture: a meta-analysis.
    Goodman CM; Cohen V; Thornby J; Netscher D
    Ann Plast Surg; 1998 Dec; 41(6):577-85; discussion 585-6. PubMed ID: 9869129
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The diagnosis of silicone breast implant rupture.
    Gorczyca DP; Gorczyca SM; Gorczyca KL
    Plast Reconstr Surg; 2007 Dec; 120(7 Suppl 1):49S-61S. PubMed ID: 18090814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of mammography, sonography and magnetic resonance imaging for detecting silicone breast implant ruptures: A retrospective observational study of 367 cases.
    Goldammer F; Pinsolle V; Dissaux C; Pélissier P
    Ann Chir Plast Esthet; 2021 Feb; 66(1):25-41. PubMed ID: 32988663
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The diagnosis of breast implant rupture: MRI findings compared with findings at explantation.
    Hölmich LR; Vejborg I; Conrad C; Sletting S; McLaughlin JK
    Eur J Radiol; 2005 Feb; 53(2):213-25. PubMed ID: 15664285
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Analysis of explanted silicone implants: a report of 300 patients.
    Robinson OG; Bradley EL; Wilson DS
    Ann Plast Surg; 1995 Jan; 34(1):1-6; discussion 6-7. PubMed ID: 7702291
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Exploration of Point-of-Care Ultrasonography for Silicone Breast Implant Rupture Detection and Classification.
    Kim JH; Kim YG; Song KY; Lim HG; Jeong JP; Sung JY; Lee AS; Park HK
    Medicina (Kaunas); 2024 Feb; 60(2):. PubMed ID: 38399593
    [No Abstract]   [Full Text] [Related]  

  • 14. Ability of Dual-Energy CT to Detect Silicone Gel Breast Implant Rupture and Nodal Silicone Spread.
    Glazebrook KN; Doerge S; Leng S; Drees TA; Hunt KN; Zingula SN; Pruthi S; Geske JR; Carter RE; McCollough CH; Fletcher JG
    AJR Am J Roentgenol; 2019 Apr; 212(4):933-942. PubMed ID: 30779664
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Magnetic resonance evaluation of breast implants and soft-tissue silicone.
    Middleton MS
    Top Magn Reson Imaging; 1998 Apr; 9(2):92-137. PubMed ID: 9622095
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.
    Ahn CY; DeBruhl ND; Gorczyca DP; Shaw WW; Bassett LW
    Plast Reconstr Surg; 1994 Oct; 94(5):620-7. PubMed ID: 7938284
    [TBL] [Abstract][Full Text] [Related]  

  • 17. PIP breast implant removal: a study of 828 cases.
    Oulharj S; Pauchot J; Tropet Y
    J Plast Reconstr Aesthet Surg; 2014 Mar; 67(3):302-7. PubMed ID: 24522122
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of capsular contracture on ultrasonic screening for silicone gel breast implant rupture.
    Medot M; Landis GH; McGregor CE; Gutowski KA; Foshager MC; Griffiths HJ; Cunningham BL
    Ann Plast Surg; 1997 Oct; 39(4):337-41. PubMed ID: 9339274
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Imaging spectrum of extracapsular silicone: correlation of US, MR imaging, mammographic, and histopathologic findings.
    Caskey CI; Berg WA; Hamper UM; Sheth S; Chang BW; Anderson ND
    Radiographics; 1999 Oct; 19 Spec No():S39-51; quiz S261-2. PubMed ID: 10517442
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Rupture of prostheses pre-filled with silicone gel].
    Sitbon E; Nicoletis C
    Ann Chir Plast Esthet; 1994 Dec; 38(6):745-57. PubMed ID: 7847724
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 11.