These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 8780370)

  • 1. Use of bioelectrical impedance analysis measurements in the clinical management of critical illness.
    Jacobs DO
    Am J Clin Nutr; 1996 Sep; 64(3 Suppl):498S-502S. PubMed ID: 8780370
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The use of bio-electrical impedance analysis (BIA) to guide fluid management, resuscitation and deresuscitation in critically ill patients: a bench-to-bedside review.
    Malbrain ML; Huygh J; Dabrowski W; De Waele JJ; Staelens A; Wauters J
    Anaesthesiol Intensive Ther; 2014; 46(5):381-91. PubMed ID: 25432557
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bioelectrical Impedance Analysis (BIA) of the association of the Japanese Kampo concept "Suidoku" (fluid disturbance) and the body composition of women.
    Murakami A; Kobayashi D; Kubota T; Zukeyama N; Mukae H; Furusyo N; Kainuma M; Shimazoe T
    BMC Complement Altern Med; 2016 Oct; 16(1):405. PubMed ID: 27770788
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bioelectrical impedance vs air displacement plethysmography and dual-energy X-ray absorptiometry to determine body composition in patients with end-stage renal disease.
    Flakoll PJ; Kent P; Neyra R; Levenhagen D; Chen KY; Ikizler TA
    JPEN J Parenter Enteral Nutr; 2004; 28(1):13-21. PubMed ID: 14763788
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Segmental bioelectrical impedance analysis.
    Lorenzo AD; Andreoli A
    Curr Opin Clin Nutr Metab Care; 2003 Sep; 6(5):551-5. PubMed ID: 12913672
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methods.
    Jaffrin MY; Morel H
    Med Eng Phys; 2008 Dec; 30(10):1257-69. PubMed ID: 18676172
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Use of bioelectrical impedance analysis measurements in the clinical management of malnutrition.
    Pencharz PB; Azcue M
    Am J Clin Nutr; 1996 Sep; 64(3 Suppl):485S-488S. PubMed ID: 8780368
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reproducibility of fluid status measured by bioelectrical impedance analysis in healthy volunteers: a key requirement to monitor fluid status in the intensive care unit.
    Gijsen M; Simons E; De Cock P; L N G Malbrain M; Wauters J; Spriet I
    Anaesthesiol Intensive Ther; 2021; 53(3):193-199. PubMed ID: 34284553
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A longitudinal comparison of body composition by total body water and bioelectrical impedance in adolescent girls.
    Phillips SM; Bandini LG; Compton DV; Naumova EN; Must A
    J Nutr; 2003 May; 133(5):1419-25. PubMed ID: 12730432
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Bioelectrical impedance analysis--part I: review of principles and methods.
    Kyle UG; Bosaeus I; De Lorenzo AD; Deurenberg P; Elia M; Gómez JM; Heitmann BL; Kent-Smith L; Melchior JC; Pirlich M; Scharfetter H; Schols AM; Pichard C;
    Clin Nutr; 2004 Oct; 23(5):1226-43. PubMed ID: 15380917
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Characterization of drug disposition and dosing using bioelectrical impedance.
    Zarowitz BJ; Peterson EL; Robert S
    Med Prog Technol; 1993-1994; 19(4):193-8. PubMed ID: 8052175
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bioelectrical impedance plethysmographic analysis of body composition in critically injured and healthy subjects.
    Frankenfield DC; Cooney RN; Smith JS; Rowe WA
    Am J Clin Nutr; 1999 Mar; 69(3):426-31. PubMed ID: 10075326
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bioelectrical impedance to estimate changes in hydration status.
    O'Brien C; Young AJ; Sawka MN
    Int J Sports Med; 2002 Jul; 23(5):361-6. PubMed ID: 12165888
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Body composition in a group of young women studied by bioelectrical impedance analysis].
    Núñez C; Carbajal A; Turrero E; Moreiras O
    Nutr Hosp; 1994; 9(4):262-7. PubMed ID: 7918793
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Segmental bioelectrical impedance analysis: theory and application of a new technique.
    Organ LW; Bradham GB; Gore DT; Lozier SL
    J Appl Physiol (1985); 1994 Jul; 77(1):98-112. PubMed ID: 7961281
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bioelectrical impedance assessment of nutritional status in critically ill patients.
    Robert S; Zarowitz BJ; Hyzy R; Eichenhorn M; Peterson EL; Popovich J
    Am J Clin Nutr; 1993 Jun; 57(6):840-4. PubMed ID: 8503350
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Identification of operational clues to dry weight prescription in hemodialysis using bioimpedance vector analysis. The Italian Hemodialysis-Bioelectrical Impedance Analysis (HD-BIA) Study Group.
    Piccoli A
    Kidney Int; 1998 Apr; 53(4):1036-43. PubMed ID: 9551415
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Assessment of human body composition using dual-energy x-ray absorptiometry and bioelectrical impedance analysis.
    Bolanowski M; Nilsson BE
    Med Sci Monit; 2001; 7(5):1029-33. PubMed ID: 11535954
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Bioelectrical impedance analysis during deresuscitation: correlation and agreement with cumulative fluid balance in ICU patients.
    Ruste M; Chabanol C; Fellahi JL; Jacquet-Lagrèze M
    J Clin Monit Comput; 2023 Apr; 37(2):679-687. PubMed ID: 36197549
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of Intravenous Infusion Solutions on Bioelectrical Impedance Spectroscopy.
    Yap J; Rafii M; Azcue M; Pencharz P
    JPEN J Parenter Enteral Nutr; 2017 May; 41(4):641-646. PubMed ID: 26637229
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.