These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 8780736)

  • 1. Global analysis of a macromolecular interaction measured on BIAcore.
    Roden LD; Myszka DG
    Biochem Biophys Res Commun; 1996 Aug; 225(3):1073-7. PubMed ID: 8780736
    [TBL] [Abstract][Full Text] [Related]  

  • 2. BIACORE data processing: an evaluation of the global fitting procedure.
    Khalifa MB; Choulier L; Lortat-Jacob H; Altschuh D; Vernet T
    Anal Biochem; 2001 Jun; 293(2):194-203. PubMed ID: 11399032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Kinetic analysis of a high-affinity antibody/antigen interaction performed by multiple Biacore users.
    Katsamba PS; Navratilova I; Calderon-Cacia M; Fan L; Thornton K; Zhu M; Bos TV; Forte C; Friend D; Laird-Offringa I; Tavares G; Whatley J; Shi E; Widom A; Lindquist KC; Klakamp S; Drake A; Bohmann D; Roell M; Rose L; Dorocke J; Roth B; Luginbühl B; Myszka DG
    Anal Biochem; 2006 May; 352(2):208-21. PubMed ID: 16564019
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interpreting kinetic rate constants from optical biosensor data recorded on a decaying surface.
    Joss L; Morton TA; Doyle ML; Myszka DG
    Anal Biochem; 1998 Aug; 261(2):203-10. PubMed ID: 9716423
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Influence of mass transfer and surface ligand heterogeneity on quantitative BIAcore binding data. Analysis of the interaction of NC10 Fab with an anti-idiotype Fab'.
    Kortt AA; Gruen LC; Oddie GW
    J Mol Recognit; 1997; 10(3):148-58. PubMed ID: 9408831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of binding constants by equilibrium titration with circulating sample in a surface plasmon resonance biosensor.
    Schuck P; Millar DB; Kortt AA
    Anal Biochem; 1998 Dec; 265(1):79-91. PubMed ID: 9866711
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Interpretation of deviations from pseudo-first-order kinetic behavior in the characterization of ligand binding by biosensor technology.
    O'Shannessy DJ; Winzor DJ
    Anal Biochem; 1996 May; 236(2):275-83. PubMed ID: 8660505
    [TBL] [Abstract][Full Text] [Related]  

  • 8. High-resolution characterization of antibody fragment/antigen interactions using Biacore T100.
    Papalia GA; Baer M; Luehrsen K; Nordin H; Flynn P; Myszka DG
    Anal Biochem; 2006 Dec; 359(1):112-9. PubMed ID: 17027901
    [TBL] [Abstract][Full Text] [Related]  

  • 9. BIACORE J: a new platform for routine biomolecular interaction analysis.
    Rich RL; Myszka DG
    J Mol Recognit; 2001; 14(4):223-8. PubMed ID: 11500968
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Kinetic analysis of antibody-antigen interactions at a supported lipid monolayer.
    Cooper MA; Williams DH
    Anal Biochem; 1999 Dec; 276(1):36-47. PubMed ID: 10585742
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Screening antibody-antigen interactions in parallel using Biacore A100.
    Säfsten P; Klakamp SL; Drake AW; Karlsson R; Myszka DG
    Anal Biochem; 2006 Jun; 353(2):181-90. PubMed ID: 16510107
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of rate and equilibrium binding constants for macromolecular interactions using surface plasmon resonance: use of nonlinear least squares analysis methods.
    O'Shannessy DJ; Brigham-Burke M; Soneson KK; Hensley P; Brooks I
    Anal Biochem; 1993 Aug; 212(2):457-68. PubMed ID: 8214588
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interpreting complex binding kinetics from optical biosensors: a comparison of analysis by linearization, the integrated rate equation, and numerical integration.
    Morton TA; Myszka DG; Chaiken IM
    Anal Biochem; 1995 May; 227(1):176-85. PubMed ID: 7668379
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Epitope mapping by surface plasmon resonance in the BIAcore.
    Johne B
    Methods Mol Biol; 1996; 66():67-76. PubMed ID: 8959705
    [No Abstract]   [Full Text] [Related]  

  • 15. BIACORE analysis of histidine-tagged proteins using a chelating NTA sensor chip.
    Nieba L; Nieba-Axmann SE; Persson A; Hämäläinen M; Edebratt F; Hansson A; Lidholm J; Magnusson K; Karlsson AF; Plückthun A
    Anal Biochem; 1997 Oct; 252(2):217-28. PubMed ID: 9344407
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Studies of protein interactions by biosensor technology: an alternative approach to the analysis of sensorgrams deviating from pseudo-first-order kinetic behavior.
    Bowles MR; Hall DR; Pond SM; Winzor DJ
    Anal Biochem; 1997 Jan; 244(1):133-43. PubMed ID: 9025919
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A theoretical and experimental study of competition between solution and surface receptors for ligand in a Biacore flow cell.
    He X; Coombs D; Myszka DG; Goldstein B
    Bull Math Biol; 2006 Jul; 68(5):1125-50. PubMed ID: 16804651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The influence of transport on the kinetics of binding to surface receptors: application to cells and BIAcore.
    Goldstein B; Coombs D; He X; Pineda AR; Wofsy C
    J Mol Recognit; 1999; 12(5):293-9. PubMed ID: 10556877
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Thermodynamic analysis of antigen-antibody binding using biosensor measurements at different temperatures.
    Zeder-Lutz G; Zuber E; Witz J; Van Regenmortel MH
    Anal Biochem; 1997 Mar; 246(1):123-32. PubMed ID: 9056193
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of antigen-antibody interactions with biosensors.
    Van Regenmortel MH; Altschuh D; Chatellier J; Christensen L; Rauffer-Bruyère N; Richalet-Secordel P; Witz J; Zeder-Lutz G
    J Mol Recognit; 1998; 11(1-6):163-7. PubMed ID: 10076831
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.