142 related articles for article (PubMed ID: 8782943)
1. Colour duplex ultrasonography versus angiography in the diagnosis of lower-extremity arterial disease.
Lai DT; Huber D; Glasson R; Grayndler V; Evans J; Hogg J; Etheridge S
Cardiovasc Surg; 1996 Jun; 4(3):384-8. PubMed ID: 8782943
[TBL] [Abstract][Full Text] [Related]
2. Colour-coded duplex ultrasonography in selection of patients for transluminal angioplasty.
Lai DT; Huber D; Glasson R; Grayndler V; Evans J; Hogg J; Etheredge S
Australas Radiol; 1995 Aug; 39(3):243-5. PubMed ID: 7487757
[TBL] [Abstract][Full Text] [Related]
3. Duplex scanning compared with intra-arterial angiography in diagnosing peripheral arterial disease: three analytical approaches.
Krnic A; Vucic N; Sucic Z
Vasa; 2006 May; 35(2):86-91. PubMed ID: 16796006
[TBL] [Abstract][Full Text] [Related]
4. Preoperative high-frequency duplex scanning of potential pedal target vessels.
Hofmann WJ; Walter J; Ugurluoglu A; Czerny M; Forstner R; Magometschnigg H
J Vasc Surg; 2004 Jan; 39(1):169-75. PubMed ID: 14718835
[TBL] [Abstract][Full Text] [Related]
5. Duplex ultrasound scanning for diagnosis of aortoiliac and femoropopliteal arterial disease.
Karacagil S; Lofberg AM; Almgren B; Granbo A; Jonsson ML; Lorelius LE; Bergqvist D
Vasa; 1994; 23(4):325-9. PubMed ID: 7817613
[TBL] [Abstract][Full Text] [Related]
6. A prospective comparison of lower limb colour-coded Duplex scanning with arteriography.
Sensier Y; Hartshorne T; Thrush A; Nydahl S; Bolia A; London NJ
Eur J Vasc Endovasc Surg; 1996 Feb; 11(2):170-5. PubMed ID: 8616648
[TBL] [Abstract][Full Text] [Related]
7. The role of duplex scanning in the diagnosis of lower limb arterial disease.
Ramaswami G; Al-Kutoubi A; Nicolaides AN; Dhanjil S; Griffin M; Belcaro G; Coen LD
Ann Vasc Surg; 1999 Sep; 13(5):494-500. PubMed ID: 10466993
[TBL] [Abstract][Full Text] [Related]
8. Value of color duplex sonography for evaluation of tibioperoneal arteries in patients with femoropopliteal obstruction: a prospective comparison with anterograde intraarterial digital subtraction angiography.
Larch E; Minar E; Ahmadi R; Schnürer G; Schneider B; Stümpflen A; Ehringer H
J Vasc Surg; 1997 Apr; 25(4):629-36. PubMed ID: 9129617
[TBL] [Abstract][Full Text] [Related]
9. Analysis of agreement between Duplex ultrasound scanning and arteriography in patients with lower limb artery disease.
Favaretto E; Pili C; Amato A; Conti E; Losinno F; Rossi C; Faccioli L; Palareti G
J Cardiovasc Med (Hagerstown); 2007 May; 8(5):337-41. PubMed ID: 17443099
[TBL] [Abstract][Full Text] [Related]
10. The potential of duplex scanning to replace aorto-iliac and femoro-popliteal angiography.
Legemate DA; Teeuwen C; Hoeneveld H; Ackerstaff RG; Eikelboom BC
Eur J Vasc Surg; 1989 Feb; 3(1):49-54. PubMed ID: 2653869
[TBL] [Abstract][Full Text] [Related]
11. Imaging of aortoiliac arterial disease. Duplex ultrasound and MR angiography versus digital subtraction angiography.
Lundin P; Svensson A; Henriksen E; Jonason T; Forssell C; Bäckbro B; Bodlund M; Ringqvist I
Acta Radiol; 2000 Mar; 41(2):125-32. PubMed ID: 10741783
[TBL] [Abstract][Full Text] [Related]
12. A comparison between colour duplex ultrasonography and arteriography for imaging infrapopliteal arterial lesions.
Sensier Y; Fishwick G; Owen R; Pemberton M; Bell PR; London NJ
Eur J Vasc Endovasc Surg; 1998 Jan; 15(1):44-50. PubMed ID: 9518999
[TBL] [Abstract][Full Text] [Related]
13. Effect of multilevel sequential stenosis on lower extremity arterial duplex scanning.
Bergamini TM; Tatum CM; Marshall C; Hall-Disselkamp B; Richardson JD
Am J Surg; 1995 Jun; 169(6):564-6. PubMed ID: 7771616
[TBL] [Abstract][Full Text] [Related]
14. Accuracy of lower extremity arterial duplex mapping.
Moneta GL; Yeager RA; Antonovic R; Hall LD; Caster JD; Cummings CA; Porter JM
J Vasc Surg; 1992 Feb; 15(2):275-83; discussion 283-4. PubMed ID: 1735888
[TBL] [Abstract][Full Text] [Related]
15. Can ultrasound replace arteriography in the management of chronic arterial occlusive disease of the lower limb?
Katsamouris AN; Giannoukas AD; Tsetis D; Kostas T; Petinarakis I; Gourtsoyiannis N
Eur J Vasc Endovasc Surg; 2001 Feb; 21(2):155-9. PubMed ID: 11237789
[TBL] [Abstract][Full Text] [Related]
16. Stenosis development at the distal anastomosis of prosthetic bypasses for aortoiliac occlusive disease. Incidence and accuracy of colour flow duplex in the diagnosis.
de Gier P; Sommeling C; van Dulken E; Truyen E; Buth J
Eur J Vasc Surg; 1993 May; 7(3):237-44. PubMed ID: 8513901
[TBL] [Abstract][Full Text] [Related]
17. Gadolinium-enhanced magnetic resonance angiography, digital subtraction angiography and duplex of the iliac arteries compared with intra-arterial pressure gradient measurements.
Wikström J; Holmberg A; Johansson L; Löfberg AM; Smedby O; Karacagil S; Ahlström H
Eur J Vasc Endovasc Surg; 2000 May; 19(5):516-23. PubMed ID: 10828234
[TBL] [Abstract][Full Text] [Related]
18. [Doppler sonography diagnosis of restenosis after percutaneous transluminal angioplasty: sensitivity and specificity of the pedal-brachial index in relation to changes in absolute arterial blood pressure].
Radak Dj; Laps KH; Jeger KA; Ilijevski N; Vojić M
Srp Arh Celok Lek; 1998; 126(3-4):83-91. PubMed ID: 9863361
[TBL] [Abstract][Full Text] [Related]
19. Value of duplex scanning compared with angiography and pressure measurement in the assessment of aortoiliac arterial lesions.
Legemate DA; Teeuwen C; Hoeneveld H; Eikelboom BC
Br J Surg; 1991 Aug; 78(8):1003-8. PubMed ID: 1913092
[TBL] [Abstract][Full Text] [Related]
20. Clinical utility of time-resolved imaging of contrast kinetics (TRICKS) magnetic resonance angiography for infrageniculate arterial occlusive disease.
Mell M; Tefera G; Thornton F; Siepman D; Turnipseed W
J Vasc Surg; 2007 Mar; 45(3):543-8; discussion 548. PubMed ID: 17223303
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]