These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 879091)

  • 1. The calibration of automated instruments for accuracy in hemoglobinometry.
    Koepke JA
    Am J Clin Pathol; 1977 Jul; 68(1 Suppl):180-4. PubMed ID: 879091
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Current methodological problems in the determination of erythrocytes, hemoglobin and hematocrit].
    Franzini C; Gobbi A; Tarantino M; Tropeano L
    Quad Sclavo Diagn; 1978 Sep; 15(3):410-24. PubMed ID: 752832
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The status of methods of calibration in hematology.
    Gilmer PR; Williams LJ
    Am J Clin Pathol; 1980 Oct; 74(4 Suppl):600-5. PubMed ID: 7435456
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The accuracy of laboratory measurements in clinical chemistry: a study of 11 routine chemistry analytes in the College of American Pathologists Chemistry Survey with fresh frozen serum, definitive methods, and reference methods.
    Ross JW; Miller WG; Myers GL; Praestgaard J
    Arch Pathol Lab Med; 1998 Jul; 122(7):587-608. PubMed ID: 9674541
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement.
    Lamhaut L; Apriotesei R; Combes X; Lejay M; Carli P; Vivien B
    Anesthesiology; 2011 Sep; 115(3):548-54. PubMed ID: 21716091
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration methods for automated hematology instruments.
    Gilmer PR; Williams LJ; Koepke JA; Bull BS
    Am J Clin Pathol; 1977 Jul; 68(1 Suppl):185-90. PubMed ID: 879092
    [TBL] [Abstract][Full Text] [Related]  

  • 7. External peer review quality assurance testing in von Willebrand disease: the recent experience of the United States College of American Pathologists proficiency testing program.
    Hayes TE; Brandt JT; Chandler WL; Eby CS; Kottke-Marchant K; Krishnan J; Lefkowitz JB; Olson JD; Rund CR; Van Cott EM; Cunningham MT
    Semin Thromb Hemost; 2006 Jul; 32(5):499-504. PubMed ID: 16862523
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A critical analysis of platelet counting methods.
    Wertz RK; Koepke JA
    Am J Clin Pathol; 1977 Jul; 68(1 Suppl):195-201. PubMed ID: 879094
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Interinstitutional comparison of bedside blood glucose monitoring program characteristics, accuracy performance, and quality control documentation: a College of American Pathologists Q-Probes study of bedside blood glucose monitoring performed in 226 small hospitals.
    Novis DA; Jones BA
    Arch Pathol Lab Med; 1998 Jun; 122(6):495-502. PubMed ID: 9625416
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibration and control in haemoglobinometry.
    van Assendelft OW; Horton BR; Parvin RM
    Clin Lab Haematol; 1990; 12 Suppl 1():31-42. PubMed ID: 2282764
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of creatinine calibration on performance of GFR estimating equations in a pooled individual patient database.
    Stevens LA; Manzi J; Levey AS; Chen J; Deysher AE; Greene T; Poggio ED; Schmid CH; Steffes MW; Zhang YL; Van Lente F; Coresh J
    Am J Kidney Dis; 2007 Jul; 50(1):21-35. PubMed ID: 17591522
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The stability of survey-assigned assay values when surveyed control materials are used in a daily interlaboratory quality control program. The College of American Pathologists Chemistry Survey--Quality Assurance Service shared pool experience.
    Lawson PL; Lawson NS; Ross JW
    Arch Pathol Lab Med; 1995 Apr; 119(4):312-33. PubMed ID: 7726725
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the Abbott Cell Dyn 3000 SL and the Coulter STKS hematology analyzers.
    Stroop DM; Triplett RC; Perrotta G; Roberts LP; Schramm RC; Comer K; Miller-Canfield P; Schumacher HR
    Ann Clin Lab Sci; 1994; 24(3):250-8. PubMed ID: 8048797
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Short report: evaluation of a simple and inexpensive photometric device for the measurement of hemoglobin.
    Borrmann S; Oyakhirome S; Esser G; Trinkle C; Issifou S; Grobusch MP; Krishna S; Kremsner PG
    Am J Trop Med Hyg; 2004 Nov; 71(5):691-2. PubMed ID: 15569807
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assignment of assay values to Coulter controls and calibrators.
    Richardson-Jones A
    Clin Lab Haematol; 1990; 12 Suppl 1():23-30. PubMed ID: 2282762
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Comparison between Coulter LH-750 and URIT-12 for measuring hemoglobin concentration].
    Qin X; Liu YP; Lin FQ; Yi Z; Xu MH; Li RL; Li TJ; Li S
    Nan Fang Yi Ke Da Xue Xue Bao; 2008 Dec; 28(12):2196-8. PubMed ID: 19114355
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The prediction of prothrombin time system performance using secondary standards.
    Koepke JA; Gilmer PR; Triplett DA; O'Sullivan MB
    Am J Clin Pathol; 1977 Jul; 68(1 Suppl):191-4. PubMed ID: 879093
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy in clinical laboratories participating in regional quality control programs.
    Rosenbaum JM
    Arch Pathol Lab Med; 1985 Jun; 109(6):485-95. PubMed ID: 3838877
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemoglobinometry: A comparison between the hemiglobincyanide method and the Coulter S counter.
    Salvati AM; Samoggia P; Taggi F; Tentori L
    Clin Chim Acta; 1977 May; 77(1):13-20. PubMed ID: 872420
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of two platelet count estimation methodologies for peripheral blood smears.
    Malok M; Titchener EH; Bridgers C; Lee BY; Bamberg R
    Clin Lab Sci; 2007; 20(3):154-60. PubMed ID: 17691671
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.