243 related articles for article (PubMed ID: 8793785)
1. Efficacy of spinal cord monitoring in scoliosis surgery in patients with cerebral palsy.
Ecker ML; Dormans JP; Schwartz DM; Drummond DS; Bulman WA
J Spinal Disord; 1996 Apr; 9(2):159-64. PubMed ID: 8793785
[TBL] [Abstract][Full Text] [Related]
2. Multimodality monitoring of transcranial electric motor and somatosensory-evoked potentials during surgical correction of spinal deformity in patients with cerebral palsy and other neuromuscular disorders.
DiCindio S; Theroux M; Shah S; Miller F; Dabney K; Brislin RP; Schwartz D
Spine (Phila Pa 1976); 2003 Aug; 28(16):1851-5; discussion 1855-6. PubMed ID: 12923474
[TBL] [Abstract][Full Text] [Related]
3. Direct spinal stimulation for intraoperative monitoring during scoliosis surgery.
Phillips LH; Blanco JS; Sussman MD
Muscle Nerve; 1995 Mar; 18(3):319-25. PubMed ID: 7870110
[TBL] [Abstract][Full Text] [Related]
4. Spinal cord monitoring in scoliosis surgery using an epidural electrode. Results of a prospective, consecutive series of 191 cases.
Accadbled F; Henry P; de Gauzy JS; Cahuzac JP
Spine (Phila Pa 1976); 2006 Oct; 31(22):2614-23. PubMed ID: 17047554
[TBL] [Abstract][Full Text] [Related]
5. [Somatosensory evoked potentials during surgery of scoliosis: significance of epidural recording].
de Gauzy JS; Roux FE; Henry P; Cahuzac JP
Rev Chir Orthop Reparatrice Appar Mot; 1999 Jul; 85(4):387-92. PubMed ID: 10457558
[TBL] [Abstract][Full Text] [Related]
6. [Contribution of somatosensory evoked potentials in the surveillance of the spinal cord during spinal surgery].
Chéliout-Héraut F; Mariambourg G; Fahed M; De Lattre J; Pouliquen JC
Rev Chir Orthop Reparatrice Appar Mot; 1991; 77(5):344-52. PubMed ID: 1836887
[TBL] [Abstract][Full Text] [Related]
7. [Neurogenic mixed evoked potential monitoring during scoliosis surgery: retrospective analysis of 149 cases].
Delécrin J; Nguyen The Tich S; Passuti N; Péréon Y
Rev Chir Orthop Reparatrice Appar Mot; 2000 Feb; 86(1):46-53. PubMed ID: 10669824
[TBL] [Abstract][Full Text] [Related]
8. Validity and reliability of spinal cord monitoring in neuromuscular spinal deformity surgery.
Padberg AM; Russo MH; Lenke LG; Bridwell KH; Komanetsky RM
J Spinal Disord; 1996 Apr; 9(2):150-8. PubMed ID: 8793784
[TBL] [Abstract][Full Text] [Related]
9. Intraoperative evoked potential monitoring of the spinal cord. A restricted filter, scalp method during Harrington instrumentation for scoliosis.
Nuwer MR; Dawson EC
Clin Orthop Relat Res; 1984 Mar; (183):42-50. PubMed ID: 6697601
[TBL] [Abstract][Full Text] [Related]
10. Spinal cord monitoring during posterior spinal instrumentation and fusion.
Bieber E; Tolo V; Uematsu S
Clin Orthop Relat Res; 1988 Apr; (229):121-4. PubMed ID: 3280196
[TBL] [Abstract][Full Text] [Related]
11. Spinal cord monitoring. Electrophysiological measures of sensory and motor function during spinal surgery.
Machida M; Weinstein SL; Yamada T; Kimura J
Spine (Phila Pa 1976); 1985 Jun; 10(5):407-13. PubMed ID: 4049106
[TBL] [Abstract][Full Text] [Related]
12. Preserving ambulatory potential in pediatric patients with cerebral palsy who undergo spinal fusion using unit rod instrumentation.
Tsirikos AI; Chang WN; Shah SA; Dabney KW; Miller F
Spine (Phila Pa 1976); 2003 Mar; 28(5):480-3. PubMed ID: 12616161
[TBL] [Abstract][Full Text] [Related]
13. [Monitoring of spinal cord function using evoked potentials during the surgical treatment of scoliosis].
Golik M; Zarzycki D
Pol Tyg Lek; 1987 Oct 5-12; 42(40-41):1269-71. PubMed ID: 3438202
[No Abstract] [Full Text] [Related]
14. [Neurophysiological monitoring in spine surgery. Spinal cord stimulation].
de Blas-Beorlegui G; Regidor-Bailly-Bailliere I; Fernández-Lorente J; León-Alonso-Cortés J; Montilla-Izquierdo S; Burgos J
Rev Neurol; 2004 Jan 1-15; 38(1):68-75. PubMed ID: 14730495
[TBL] [Abstract][Full Text] [Related]
15. The clinical application of neurogenic motor evoked potentials to monitor spinal cord function during surgery.
Owen JH; Bridwell KH; Grubb R; Jenny A; Allen B; Padberg AM; Shimon SM
Spine (Phila Pa 1976); 1991 Aug; 16(8 Suppl):S385-90. PubMed ID: 1785092
[TBL] [Abstract][Full Text] [Related]
16. Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion.
Bose B; Sestokas AK; Schwartz DM
Spine J; 2004; 4(2):202-7. PubMed ID: 15016399
[TBL] [Abstract][Full Text] [Related]
17. Syringomyelia. A potential risk factor in scoliosis surgery.
Noordeen MH; Taylor BA; Edgar MA
Spine (Phila Pa 1976); 1994 Jun; 19(12):1406-9. PubMed ID: 8066525
[TBL] [Abstract][Full Text] [Related]
18. Upper-limb somatosensory evoked potential monitoring in lumbosacral spine surgery: a prognostic marker for position-related ulnar nerve injury.
Chung I; Glow JA; Dimopoulos V; Walid MS; Smisson HF; Johnston KW; Robinson JS; Grigorian AA
Spine J; 2009 Apr; 9(4):287-95. PubMed ID: 18684675
[TBL] [Abstract][Full Text] [Related]
19. Monitoring of scoliosis surgery with epidurally recorded motor evoked potentials (D wave) revealed false results.
Ulkatan S; Neuwirth M; Bitan F; Minardi C; Kokoszka A; Deletis V
Clin Neurophysiol; 2006 Sep; 117(9):2093-101. PubMed ID: 16844406
[TBL] [Abstract][Full Text] [Related]
20. [Application of CWT to extract characteristic monitoring parameters during spine surgery].
Chen P; Wu B; Hu Y
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2005 Oct; 22(5):947-50. PubMed ID: 16294728
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]