BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 8795271)

  • 1. HPLC determination of carnitine and acylcarnitines in human plasma by means of fluorescence labeling using 2-(4-hydrazinocarbonylphenyl)-4,5-diphenylimidazole.
    Kuroda N; Ohyama Y; Nakashima K; Nakashima K; Akiyama S
    Chem Pharm Bull (Tokyo); 1996 Aug; 44(8):1525-9. PubMed ID: 8795271
    [TBL] [Abstract][Full Text] [Related]  

  • 2. 2-(4-Hydrazinocarbonylphenyl)-4,5-diphenylimidazole as a versatile fluorescent derivatization reagent for the high-performance liquid chromatographic analysis of free fatty acids.
    Nakashima K; Taguchi Y; Kuroda N; Akiyama S; Duan G
    J Chromatogr; 1993 Sep; 619(1):1-8. PubMed ID: 8245146
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantification of plasma carnitine and acylcarnitines by high-performance liquid chromatography-tandem mass spectrometry using online solid-phase extraction.
    Morand R; Donzelli M; Haschke M; Krähenbühl S
    Anal Bioanal Chem; 2013 Nov; 405(27):8829-36. PubMed ID: 23995505
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of L-carnitine, acetyl-L-carnitine and propionyl-L-carnitine in human plasma by high-performance liquid chromatography after pre-column derivatization with 1-aminoanthracene.
    Longo A; Bruno G; Curti S; Mancinelli A; Miotto G
    J Chromatogr B Biomed Appl; 1996 Nov; 686(2):129-39. PubMed ID: 8971593
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of carnitine and saturated-acyl group carnitines in human urine by high-performance liquid chromatography with fluorescence detection.
    Kamimori H; Hamashima Y; Konishi M
    Anal Biochem; 1994 May; 218(2):417-24. PubMed ID: 8074302
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Quantification of free carnitine, individual short- and medium-chain acylcarnitines, and total carnitine in plasma by high-performance liquid chromatography.
    Minkler PE; Hoppel CL
    Anal Biochem; 1993 Aug; 212(2):510-8. PubMed ID: 8214594
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitation of long-chain acylcarnitines by HPLC/fluorescence detection: application to plasma and tissue specimens from patients with carnitine palmitoyltransferase-II deficiency.
    Minkler PE; Kerner J; North KN; Hoppel CL
    Clin Chim Acta; 2005 Feb; 352(1-2):81-92. PubMed ID: 15653102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quantification of Free Carnitine and Acylcarnitines in Plasma or Serum Using HPLC/MS/MS.
    Scott D; Heese B; Garg U
    Methods Mol Biol; 2016; 1378():11-9. PubMed ID: 26602112
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of highly soluble L-carnitine in biological samples by reverse phase high performance liquid chromatography with fluorescent derivatization.
    Cao QR; Ren S; Park MJ; Choi YJ; Lee BJ
    Arch Pharm Res; 2007 Aug; 30(8):1041-6. PubMed ID: 17879759
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rapid quantitative analysis of carnitine and acylcarnitines by ultra-high performance-hydrophilic interaction liquid chromatography-tandem mass spectrometry.
    Kivilompolo M; Öhrnberg L; Orešič M; Hyötyläinen T
    J Chromatogr A; 2013 May; 1292():189-94. PubMed ID: 23336946
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of carnitine and acylcarnitines in plasma by high-performance liquid chromatography/electrospray ionization ion trap tandem mass spectrometry.
    Vernez L; Wenk M; Krähenbühl S
    Rapid Commun Mass Spectrom; 2004; 18(11):1233-8. PubMed ID: 15164354
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Measurement of free carnitine and acylcarnitines in plasma by HILIC-ESI-MS/MS without derivatization.
    Peng M; Liu L; Jiang M; Liang C; Zhao X; Cai Y; Sheng H; Ou Z; Luo H
    J Chromatogr B Analyt Technol Biomed Life Sci; 2013 Aug; 932():12-8. PubMed ID: 23816563
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Validated method for the quantification of free and total carnitine, butyrobetaine, and acylcarnitines in biological samples.
    Minkler PE; Stoll MS; Ingalls ST; Kerner J; Hoppel CL
    Anal Chem; 2015 Sep; 87(17):8994-9001. PubMed ID: 26270397
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of carnitine and acylcarnitines in biological samples by capillary electrophoresis-mass spectrometry.
    Heinig K; Henion J
    J Chromatogr B Biomed Sci Appl; 1999 Dec; 735(2):171-88. PubMed ID: 10670733
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Simultaneous quantification of acylcarnitine isomers containing dicarboxylic acylcarnitines in human serum and urine by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry.
    Maeda Y; Ito T; Suzuki A; Kurono Y; Ueta A; Yokoi K; Sumi S; Togari H; Sugiyama N
    Rapid Commun Mass Spectrom; 2007; 21(5):799-806. PubMed ID: 17279485
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Low levels of short- and medium-chain acylcarnitines in HIV-infected patients.
    Waagsbø B; Svardal A; Ueland T; Landrø L; Øktedalen O; Berge RK; Flo TH; Aukrust P; Damås JK
    Eur J Clin Invest; 2016 May; 46(5):408-17. PubMed ID: 26913383
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitation of short- and medium-chain acylcarnitines in plasma by radioisotopic exchange/high-performance liquid chromatography.
    Schmidt-Sommerfeld E; Zhang L; Bobrowski PJ; Penn D
    Anal Biochem; 1995 Oct; 231(1):27-33. PubMed ID: 8678315
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantification of carnitine and acylcarnitines in biological matrices by HPLC electrospray ionization-mass spectrometry.
    Minkler PE; Stoll MS; Ingalls ST; Yang S; Kerner J; Hoppel CL
    Clin Chem; 2008 Sep; 54(9):1451-62. PubMed ID: 18678604
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of carnitine and acylcarnitines in human urine by means of microextraction in packed sorbent and hydrophilic interaction chromatography-ultra-high-performance liquid chromatography-tandem mass spectrometry.
    Magiera S; Baranowski J
    J Pharm Biomed Anal; 2015 May; 109():171-6. PubMed ID: 25770415
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sensitive high-performance liquid chromatographic determination with fluorescence detection of phenol and chlorophenols with 4-(4,5-diphenyl-1H-imidazol-2-yl)benzoyl chloride as a labeling reagent.
    Wada M; Kinoshita S; Itayama Y; Kuroda N; Nakashima K
    J Chromatogr B Biomed Sci Appl; 1999 Jan; 721(2):179-86. PubMed ID: 10052690
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.