BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

242 related articles for article (PubMed ID: 8795519)

  • 1. Infection of endovascular stents in a swine model.
    Thibodeaux LC; James KV; Lohr JM; Welling RE; Roberts WH
    Am J Surg; 1996 Aug; 172(2):151-4. PubMed ID: 8795519
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Infectibility of endovascular stents following antibiotic prophylaxis or after arterial wall incorporation.
    Paget DS; Bukhari RH; Zayyat EJ; Lohr JM; Roberts WH; Welling RE
    Am J Surg; 1999 Sep; 178(3):219-24. PubMed ID: 10527443
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Endovascular stent infection with delayed bacterial challenge.
    Hearn AT; James KV; Lohr JM; Thibodeaux LC; Roberts WH; Welling RE
    Am J Surg; 1997 Aug; 174(2):157-9. PubMed ID: 9293834
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Balloon-expandable covered stent therapy of complex endovascular pathology.
    Giles H; Lesar C; Erdoes L; Sprouse R; Myers S
    Ann Vasc Surg; 2008 Nov; 22(6):762-8. PubMed ID: 18922676
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reaction to injury following balloon angioplasty and intravascular stent placement in the canine femoral artery.
    Salam TA; Taylor B; Suggs WD; Hanson SR; Lumsden AB
    Am Surg; 1994 May; 60(5):353-7. PubMed ID: 8161086
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of three polytetrafluoroethylene stent-grafts in a model of neointimal hyperplasia.
    Dolmatch B; Dong YH; Heeter Z
    J Vasc Interv Radiol; 2007 Apr; 18(4):527-34. PubMed ID: 17446544
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Restenosis following placement of an intracoronary heparin treated tantulum stent in the hyperlipidemic miniature swine model.
    Jenkins JS; Webel R; Laughlin MH; Rowland SM; Yoklavich MF; Amann JF; Branson K; Myers PR
    J Invasive Cardiol; 1995; 7(6):173-82. PubMed ID: 10155102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Percutaneous interventions for treatment of iliac artery stenoses and occlusions.
    Vorwerk D; Günther RW
    World J Surg; 2001 Mar; 25(3):319-26; discussion 326-7. PubMed ID: 11343185
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Percutaneous transluminal angioplasty (PTA) alone versus PTA with balloon-expandable stent placement for short-segment femoropopliteal artery disease: a metaanalysis of randomized trials.
    E Y; He N; Wang Y; Fan H
    J Vasc Interv Radiol; 2008 Apr; 19(4):499-503. PubMed ID: 18375292
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Experimental Results with the Multi-Linkª Stent in a Porcine Model.
    Thomas WJ; Laird JR; Bailey L; Hoopes TG; Hillhouse R; Scott D; Jones R; Virmani R; Carter AJ
    J Invasive Cardiol; 1997 Sep; 9(7):453-460. PubMed ID: 10762942
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Arterial wall temperature following coronary stent implantation in pigs: the role of post-stent inflammation.
    Diamantopoulos L; Huang Y; Liu X; Li S; Desmet W; Van De Werf F; De Scheerder I
    J Invasive Cardiol; 2003 Apr; 15(4):191-7. PubMed ID: 12668845
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Endovascular therapy in combination with conventional vascular surgery for the treatment of peripheral arterial obliterative disease].
    Gassel HJ; Kellersmann R; Franke S; Thiede A
    Zentralbl Chir; 2002 Feb; 127(2):99-104. PubMed ID: 11894210
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Percutaneous revascularization of chronic iliac artery occlusions with primary stent placement].
    Fava M; Loyola MS
    Rev Med Chil; 1999 Aug; 127(8):895-902. PubMed ID: 10752249
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intravascular stents. General principles and status of lower-extremity arterial applications.
    Becker GJ
    Circulation; 1991 Feb; 83(2 Suppl):I122-36. PubMed ID: 1991395
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [4 years' experience with a balloon-expandable endoprosthesis. Experimental and clinical application].
    Kauffmann GW; Richter GM; Nöldge G; Roeren T; Landwehr P; Lackner K
    Radiologe; 1991 Apr; 31(4):202-9. PubMed ID: 1829841
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Iliac arterial occlusive disease: cost-effectiveness analysis of stent placement versus percutaneous transluminal angioplasty. Dutch Iliac Stent Trial Study Group.
    Bosch JL; Tetteroo E; Mali WP; Hunink MG
    Radiology; 1998 Sep; 208(3):641-8. PubMed ID: 9722840
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Percutaneous implantation of vascular endoprostheses (stents) in the iliac and femoral arteries].
    Günther RW; Vorwerk D; Bohndorf K; el-Din A; Peters I; Messmer BJ
    Dtsch Med Wochenschr; 1989 Oct; 114(40):1517-23. PubMed ID: 2791904
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cost-effectiveness of percutaneous treatment of iliac artery occlusive disease in the United States.
    Bosch JL; Haaring C; Meyerovitz MF; Cullen KA; Hunink MG
    AJR Am J Roentgenol; 2000 Aug; 175(2):517-21. PubMed ID: 10915706
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Stent placement with real time MRI guidance: initial animal experiment experiences].
    Bücker A; Neuerburg JM; Adam G; Schürmann K; Rasche V; van Vaals JJ; Molgaard-Nielsen A; Günther RW
    Rofo; 1998 Dec; 169(6):655-7. PubMed ID: 9930222
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Mid-term follow-up after placement of the new balloon-expendable VIP-stent into the iliac arteries].
    Jahnke T; Brossmann J; Voshage G; Hilbert C; Müller-Hülsbeck S; Grimm J; Toellner D; Heller M
    Rofo; 2000 Apr; 172(4):381-5. PubMed ID: 10961224
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.