These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 8798795)

  • 1. O2 flux optode: a new sensing principle to determine the oxygen flux and other gas diffusions.
    Lübbers DW; Köster T; Holst GA
    Adv Exp Med Biol; 1996; 388():59-68. PubMed ID: 8798795
    [No Abstract]   [Full Text] [Related]  

  • 2. Comparison of Clark electrode and optode for measurement of tissue oxygen tension.
    Hopf HW; Hunt TK
    Adv Exp Med Biol; 1994; 345():841-7. PubMed ID: 8079796
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optical oxygen sensor using fluorescence lifetime measurement.
    Bambot S; Holavanahali R; Lakowicz JR; Carter GM; Rao G
    Adv Exp Med Biol; 1994; 361():197-205. PubMed ID: 7597944
    [No Abstract]   [Full Text] [Related]  

  • 4. Effect of optode separation on brain penetration in adults.
    Harris DN; Bailey SM; Cowans F; Wertheim D
    Adv Exp Med Biol; 1996; 388():133-5. PubMed ID: 8798803
    [No Abstract]   [Full Text] [Related]  

  • 5. A new measuring device for non-invasive determination of oxygen partial pressure and oxygen conductance of the skin and other tissues.
    Niehoff K; Barnikol WK
    Adv Exp Med Biol; 1999; 471():705-14. PubMed ID: 10659205
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Oxygen electrodes and optodes and their application in vivo.
    Lübbers DW
    Adv Exp Med Biol; 1996; 388():13-34. PubMed ID: 8798790
    [No Abstract]   [Full Text] [Related]  

  • 7. The use of concentrated NaNO3 in tcPO2 electrodes to diminish O2 consumption and dehydration drift.
    Thunstrom AM; Severinghaus JW
    Acta Anaesthesiol Scand Suppl; 1978; 68():55-62. PubMed ID: 279201
    [No Abstract]   [Full Text] [Related]  

  • 8. Experimentally measured optical pathlengths for the adult head, calf and forearm and the head of the newborn infant as a function of inter optode spacing.
    van der Zee P; Cope M; Arridge SR; Essenpreis M; Potter LA; Edwards AD; Wyatt JS; McCormick DC; Roth SC; Reynolds EO
    Adv Exp Med Biol; 1992; 316():143-53. PubMed ID: 1288074
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a specific and highly sensitive optical chemical sensor for determination of Hg(II) based on a new synthesized ionophore.
    Firooz AR; Ensafi AA; Karimi K; Sharghi H
    Mater Sci Eng C Mater Biol Appl; 2013 Oct; 33(7):4167-72. PubMed ID: 23910329
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increase of skin O2 diffusion resistance with birthweight.
    Versmold HT; Tooley WH; Severinghaus JW
    Birth Defects Orig Artic Ser; 1979; 15(4):271-2. PubMed ID: 534706
    [No Abstract]   [Full Text] [Related]  

  • 11. Measurement of heated skin O2 diffusion conductance and PO2 sensor induced O2 gradient.
    Eberhard P; Severinghaus JW
    Acta Anaesthesiol Scand Suppl; 1978; 68():1-3. PubMed ID: 279189
    [TBL] [Abstract][Full Text] [Related]  

  • 12. NIRS in adults--effects of increasing optode separation.
    Harris DN; Cowans FM; Wertheim DA; Hamid S
    Adv Exp Med Biol; 1994; 345():837-40. PubMed ID: 8079795
    [No Abstract]   [Full Text] [Related]  

  • 13. A unique noninvasive approach to monitoring dissolved O2 and CO2 in cell culture.
    Chatterjee M; Ge X; Uplekar S; Kostov Y; Croucher L; Pilli M; Rao G
    Biotechnol Bioeng; 2015 Jan; 112(1):104-10. PubMed ID: 25082532
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of oxygen diffusion to a measuring probe in animal tissue.
    Stuck JD; Howell JA; Cullinan HT
    J Theor Biol; 1971 Jun; 31(3):509-32. PubMed ID: 5556148
    [No Abstract]   [Full Text] [Related]  

  • 15. The oxygen optode: an improved method of assessing flap blood flow and viability.
    Golde AR; Mahoney JL
    J Otolaryngol; 1994 Apr; 23(2):138-44. PubMed ID: 8028073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Skin oxygen tension, skin oxygen consumption, and skin blood flow measured by a tc-pO2 electrode.
    Jaszczak P
    Acta Physiol Scand Suppl; 1991; 603():53-7. PubMed ID: 1789131
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of membrane-covered oxygen cathodes in tissue.
    Albanese RA
    J Theor Biol; 1971 Oct; 33(1):91-103. PubMed ID: 5130672
    [No Abstract]   [Full Text] [Related]  

  • 18. Permeability and diffusion coefficient of oxygen in membranes for oxygen electrodes.
    Evans NT; Quinton TH
    Respir Physiol; 1978 Oct; 35(1):89-99. PubMed ID: 734252
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Problems of calibration and stabilization of tcPO2 electrodes.
    Severinghaus JW; Thunstrom A
    Acta Anaesthesiol Scand Suppl; 1978; 68():68-72. PubMed ID: 279203
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transcutaneous CO2 and O2 diffusion.
    Berardesca E; Maibach H
    Skin Pharmacol; 1993; 6(1):3-9. PubMed ID: 8489772
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.