These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

157 related articles for article (PubMed ID: 8803766)

  • 1. Wear assessment in bileaflet heart valves.
    Arru P; Rinaldi S; Stacchino C; Vallana F
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S133-43; discussion 144-8. PubMed ID: 8803766
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical cardiac valve prostheses: wear characteristics and magnitudes in three bileaflet valves.
    Elizondo DR; Boland ED; Ambrus JR; Kurk JL
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S115-23; discussion 144-8. PubMed ID: 8803764
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pitfalls and outcomes from accelerated wear testing of mechanical heart valves.
    Campbell A; Baldwin T; Peterson G; Bryant J; Ryder K
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S124-32; discussion 144-8. PubMed ID: 8803765
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An initial investigation into the wear and damage within the pivots of three types of bileaflet mechanical heart valves.
    King MJ; Olin CL; Fisher J
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S111-4; discussion 144-8. PubMed ID: 8803763
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In-vitro assessment of the wear development mechanism and stabilization of wear in the Edwards MIRA/Sorin Bicarbon mechanical heart valve orifice ring.
    Reul H; Schmitz C; Pfaff EM; Hohlstein C; Schmidt PA; Rau G; Arru P
    J Heart Valve Dis; 2002 May; 11(3):409-18; discussion 418. PubMed ID: 12056736
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Early wear development in a novel mechanical heart valve prosthesis made from polymeric materials.
    Medart D; Steinseifer U; Reul H; Schmitz-Rode T
    J Heart Valve Dis; 2006 Sep; 15(5):710-5. PubMed ID: 17044379
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical performance of pyrolytic carbon in prosthetic heart valve applications.
    Cao H
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S32-49. PubMed ID: 8794031
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Structural integrity assessment of heart valve prostheses: a damage tolerance analysis of the CarboMedics Prosthetic Heart Valve.
    Ryder JK; Cao H
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S86-96. PubMed ID: 8803760
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Relationship between some design characteristics and wear in the Bicarbon heart valve prosthesis.
    Arru P; Rinaldi S; Stacchino C; Vallana F
    Int J Artif Organs; 1994 May; 17(5):280-93. PubMed ID: 7960197
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Early wear development in a novel mechanical heart valve prosthesis made from polymeric materials.
    Medart D; Steinseifer U; Reul H; Schmitz-Rode T
    J Heart Valve Dis; 2006 Jul; 15(4):557-62. PubMed ID: 16901054
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fatigue of isotropic pyrolytic carbon used in mechanical heart valves.
    Ma L; Sines G
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S59-64. PubMed ID: 8794033
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of repetitive impact on the mechanical strength of pyrolytic carbon.
    Kepner J; Cao H
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S50-8. PubMed ID: 8794027
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Finite element analysis of indentation tests on pyrolytic carbon.
    Gilpin CB; Haubold AD; Ely JL
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S72-8. PubMed ID: 8794040
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Material properties, biocompatibility, and wear resistance of the Medtronic pyrolytic carbon.
    Leuer LH; Gross JM; Johnson KM
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S105-9; discussion 110. PubMed ID: 8803762
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fatigue and fracture of pyrolytic carbon: a damage- tolerant approach to structural integrity and life prediction in "ceramic" heart valve prostheses.
    Ritchie RO
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S9-31. PubMed ID: 8794026
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamic impact stress analysis of a bileaflet mechanical heart valve.
    Yuan Q; Xu L; Ngoi BK; Yeo TJ; Hwang NH
    J Heart Valve Dis; 2003 Jan; 12(1):102-9. PubMed ID: 12578344
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Wear patterns in the Sorin Bicarbon mechanical heart valve: a clinical explant study.
    Hasenkam JM; Pasquino E; Stacchino C; Arru P; Vallana F; Paulsen PK
    J Heart Valve Dis; 1997 Mar; 6(2):105-14. PubMed ID: 9130116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro comparison of bileaflet aortic heart valve prostheses. St. Jude Medical, CarboMedics, modified Edwards-Duromedics, and Sorin-Bicarbon valves.
    Reul H; van Son JA; Steinseifer U; Schmitz B; Schmidt A; Schmitz C; Rau G
    J Thorac Cardiovasc Surg; 1993 Sep; 106(3):412-20. PubMed ID: 8361181
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Structural failure of pyrolytic carbon heart valves.
    Richard G; Cao H
    J Heart Valve Dis; 1996 Jun; 5 Suppl 1():S79-85. PubMed ID: 8803759
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hydrodynamic characteristics of bileaflet mechanical heart valves in an artificial heart: cavitation and closing velocity.
    Lee H; Homma A; Taenaka Y
    Artif Organs; 2007 Jul; 31(7):532-7. PubMed ID: 17584477
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.