BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 8815378)

  • 1. Lung compensation in total body irradiation: a radiographic method.
    Hussein S; Kennelly GM
    Med Phys; 1996 Mar; 23(3):357-60. PubMed ID: 8815378
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Lung compensator design using an electronic portal imaging device.
    Parsaei H; Hussein S; el-Khatib E
    Med Dosim; 1999; 24(1):67-71. PubMed ID: 10100170
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Variation of sensitometric curves of radiographic films in high energy photon beams.
    Danciu C; Proimos BS; Rosenwald JC; Mijnheer BJ
    Med Phys; 2001 Jun; 28(6):966-74. PubMed ID: 11439493
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of measured and calculated dose distributions in lung after electron beam treatment of the chest wall.
    Seuntjens J; Van der Plaetsen A; Thierens H; Piessens M
    Med Phys; 1994 Dec; 21(12):1959-68. PubMed ID: 7700204
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Dosimetry in translation total body irradiation technique: a computer treatment planning approach and an experimental study concerning lung sparing.
    Zabatis Ch; Koligliatis T; Xenofos S; Pistevou K; Psarakos K; Haritanti A; Beroukas K
    J BUON; 2008; 13(2):253-62. PubMed ID: 18555474
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A patient-specific Monte Carlo dose-calculation method for photon beams.
    Wang L; Chui CS; Lovelock M
    Med Phys; 1998 Jun; 25(6):867-78. PubMed ID: 9650174
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Total body irradiation, toward optimal individual delivery: dose evaluation with metal oxide field effect transistors, thermoluminescence detectors, and a treatment planning system.
    Bloemen-van Gurp EJ; Mijnheer BJ; Verschueren TA; Lambin P
    Int J Radiat Oncol Biol Phys; 2007 Nov; 69(4):1297-304. PubMed ID: 17881143
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Physical aspects of total-body irradiation at the Middlesex Hospital (UCL group of hospitals), London 1988-1993: I. Phantom measurements and planning methods.
    Planskoy B; Bedford AM; Davis FM; Tapper PD; Loverock LT
    Phys Med Biol; 1996 Nov; 41(11):2307-26. PubMed ID: 8938028
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measured lung dose correction factors for 50 MV photons.
    Blomquist M; Karlsson M
    Phys Med Biol; 1998 Nov; 43(11):3225-34. PubMed ID: 9832013
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of field-in-field technique for total body irradiation.
    Onal C; Sonmez A; Arslan G; Sonmez S; Efe E; Oymak E
    Int J Radiat Oncol Biol Phys; 2012 Aug; 83(5):1641-8. PubMed ID: 22284688
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Two-dimensional film dosimetry application in heterogeneous materials exposed to megavoltage photon beams.
    Mayer R; Williams A; Frankel T; Cong Y; Simons S; Yang N; Timmerman R
    Med Phys; 1997 Mar; 24(3):455-60. PubMed ID: 9089597
    [TBL] [Abstract][Full Text] [Related]  

  • 12. TBI lung dose comparisons using bilateral and anteroposterior delivery techniques and tissue density corrections.
    Bailey DW; Wang IZ; Lakeman T; Hales LD; Singh AK; Podgorsak MB
    J Appl Clin Med Phys; 2015 Mar; 16(2):5293. PubMed ID: 26103198
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dosimetry of 6-MV x-ray beam penumbra.
    Metcalfe P; Kron T; Elliott A; Wong T; Hoban P
    Med Phys; 1993; 20(5):1439-45. PubMed ID: 8289726
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Commissioning of total body irradiation using plastic bead bags.
    Akino Y; Maruoka S; Yano K; Abe H; Isohashi F; Seo Y; Tamari K; Hirata T; Kawakami M; Nakae Y; Tanaka Y; Ogawa K
    J Radiat Res; 2020 Nov; 61(6):959-968. PubMed ID: 32876686
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Technique and dosimetry of total body irradiations at Ulm.
    Blank P; Weidenmaier W; Schneider E; Röttinger EM
    Strahlenther Onkol; 1986 Apr; 162(4):256-8. PubMed ID: 3085251
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pencil beam approach for correcting the energy dependence artifact in film dosimetry for IMRT verification.
    Kirov AS; Caravelli G; Palm A; Chui C; LoSasso T
    Med Phys; 2006 Oct; 33(10):3690-9. PubMed ID: 17089835
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery.
    Robar JL; Clark BG
    Med Phys; 2000 May; 27(5):978-87. PubMed ID: 10841400
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Total body irradiation-an attachment free sweeping beam technique.
    Härtl PM; Treutwein M; Hautmann MG; März M; Pohl F; Kölbl O; Dobler B
    Radiat Oncol; 2016 Jun; 11():81. PubMed ID: 27287010
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dose evaluation in lung-equivalent media in high-energy photon external radiotherapy.
    Duch MA; Carrasco P; Ginjaume M; Jornet N; Ortega X; Ribas M
    Radiat Prot Dosimetry; 2006; 120(1-4):43-7. PubMed ID: 16644942
    [TBL] [Abstract][Full Text] [Related]  

  • 20. White polystyrene as a substitute for water in high energy photon dosimetry.
    Christ G
    Med Phys; 1995 Dec; 22(12):2097-100. PubMed ID: 8746716
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.